ADDER Infinity 101T-DP DisplayPort Video IP KVM Extender User Guide

June 6, 2024
ADDER

ADDER logo g12

ADDERLink INFINITY 101T

Quick Start

Welcome

This quick start guide covers some of the key points of the ALIF101T unit. Full user details and setup instructions can be found at www.adder.com/en /kvm-solutions/adderlink-infinity-101t

Initial configuration

Please see the next page for Connection details.

ALIF units can be linked in two mains ways: Direct or Networked.

Direct linking

Where ALIF transmitters and receivers are directly linked to each other, very little configuration action is required, provided that they both have their factory default settings in place – just link them together. If the standard settings have been changed in a previous installation, you merely need to perform a manual factory reset on each unit. Please see the next page for further details.

Infinity 101T-DP - Direct linking

Networked linking
Where ALIF units are connected via networked links, you can either configure them individually, or configure them collectively using an AIM server:

  • Configuring networked ALIF units individually – You need to specify the network addresses of the ALIF units so that they can locate each other. This is done by running the ADDERLink INFINITY browser-based configuration utility on a computer system linked to the same network as the ALIF units. Please see the next page for further details.
  • Configuring networked ALIF units collectively – The ADDERLink INFINITY Management (AIM) server allows you to configure, control and coordinate any number of ALIF transmitters and receivers from a single application. See adder.com for details.

Note: If you are using one or more ALIF101T transmitters within an installation managed by an AIM server, the AIM server must be running firmware version 4.12 or above.

Infinity 101T-DP - Networked linking

IMPORTANT: When using AIM to configure ALIF units, it is vital that all units that you wish to locate and control are set to their factory default settings. Otherwise they will not be located by the AIM server. If necessary, perform a manual factory reset on each ALIF unit. See next page.

Connections

Infinity 101T-DP - Connections

  1. Cable tie mounting slot
  2. Status indicators (see below)
  3. DisplayPort or HDMI connector input
  4. Optional external power input
  5. Ethernet port (plus indicators) – Either link directly to an ALIF receiver or via a network switch
  6. Reset button (see below right)
  7. Red USB plug provides power only when the external power adapter is not present
  8. Black USB plug provides USB signals (plus power if the external power adapter is not present)

Power sourcing summary

Power adapter Black USB Red USB Power sourced…
…from both USB plugs.
…from power adapter only.
…from power adapter only, unless it becomes unavailable, in which case

power will be taken from both USB plugs after a short interruption.

Main status indicators

• Off| No power
• Green| Operating – Video, USB and network link all present
• Orange link| Operating – But video, USB and/or network missing.
• Red| (momentarily) Unit is booting up, or (consistently) Unit has failed, try rebooting.
• Red/green flashing| Unit is in backup mode.
• Blue| Factory reset has been activated.
• Red/blue flashing| Unit is in upgrade mode.
• Fast green flash| Unit is in identify mode.

ALIF browser-based configuration utility

Use this utility when configuring the ALIF101T to work with ALIF receivers which are linked via a network. You will need to use a computer connected to the same network as the ALIF101T unit (you can also connect them directly).

To access the browser-based configuration utility
Run a web browser on your computer and enter the standard IP address of the ALIF101T unit:

169.254.1.33

Note: If the IP address of ALIF101T unit has been changed and is not known, providing it is appropriate to do so, perform a manual factory reset (see below) to restore the default address.

The opening page of the ALIF configuration utility should be displayed:

Infinity 101T-DP - ALIF configuration utility

Full user details and setup instructions can be found at:
www.adder.com/en/kvm-solutions/adderlink-infinity- 101t

To perform a manual factory reset

A factory reset returns ALIF101T unit to its default configuration.

  1. Power on the ALIF101T unit.
  2. Use a narrow implement (e.g. a straightened-out paper clip) to press-and-hold the recessed reset button on the front panel for roughly fifteen seconds, until the status indicators turn blue (Note: alternating red/green indications will occur during the fifteen second period while the button is still pressed).
  3. Release the reset switch. The indicators will remain blue for a short while (less than ten seconds) while ALIF101T unit configures itself and should then change to green if all connections are correct; or orange if one or more of the video, USB and/or network links are missing.
    NOTE: If you are performing a factory reset and intend to disconnect the power immediately after the reset, you must wait at least 30 seconds after you have released the reset button for it to complete the process.

| www.adder.com

© 2020 Adder Technology Limited • All trademarks are acknowledged.
Part No. MAN-QS-ALIF101T-ADDER_V1.0

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals