ADJ PAR Z100 3K White LED Stage Par Can Instruction Manual

June 6, 2024
ADJ

PAR Z100 3K User Instructions

©2018 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands, and product names are trademarks or registered trademarks of their respective companies.
ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient, and negligent assembly, installation, rigging, and operation of this product.

DOCUMENT VERSION
Please check www.adj.com for the latest revision/update of this guide.

Date| Document Version| Software Version >| DMX Channel Mode|
---|---|---|---|---
09/27/17| 1| 1.0| 1/2/3| Initial Release
01/02/18| 2| 1.2| 1/2/3/4| Added: RDM Protocol Support, 4 CH DMX
Mode, Stage 2 Dimmer Curve, & Default Settings System Menu

Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help to protect the environment.
Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!

Unpacking: Thank you for purchasing the Par Z100 3K by ADJ Products, LLC. Every Par Z100 3K has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for any damage and be sure all equipment necessary to operate the unit has arrived intact. In the event, the damage has been found or parts are missing, please contact our toll-free customer support number for further instructions. Please do not return this unit to your dealer without contacting customer support first.
Introduction: The Par Z100 3K is a DMX intelligent, zooming, LED par fixture. The Par Z100 3K operates as a stand-alone fixture. This fixture is suitable for theaters, studios, retail stores, and other similar locations. For best results use fog or special effects smoke to enhance the beam’s projections.
Customer Support: ADJ Products, LLC provides a toll-free customer support line, to provide help and to answer any question should you encounter problems during your setup or initial operation. You may also visit us on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through  Friday 8:00 a.m. to 4:30 p.m. Pacific Standard Time.

Voice: 800-322-6337
Fax: 323-582-2941
E-mail: support@americandj.com

Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly into the light source at all times!

Par Z100 3K

General Instructions

To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.

Features

  • DMX-512 & RDM Protocol Support (4 DMX Channel Modes:
    1 Channel, 2 Channels, 3 Channels & 4 Channels)

  • 5-Pin XLR In/Out Connections

  • powerCON In/Out Connections

  • 6 Dimmer Curve Modes

  • Digital Display for Address and Function Setting

  • Gamma Correction Adjustment

  • Dimming Frequency Adjustment

  • Multiple Unit Power Linking (See page 19)

Warranty Registration

The Par Z100 3K carries a 2 year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase and war- ranty. You may also register your product online at www.adjproducts.com. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. If the unit is under warranty you must provide a copy of your proof of purchase invoice. Please contact ADJ Products, LLC customer support for an R.A. number.

Handling Precautions

Caution! There are no user-serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC. During operation, the housing may become extremely hot. Avoid touching the unit with bare hands while in use.  ADJ Products, LLC will not accept any liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to this unit.

Safety Precautions

For Your Own Personal Safety, Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit!

  • To reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture
  • Do not spill water or other liquids into or onto your unit.
  • Be sure that the local power outlet matches the required voltage for your unit.
  • Do not attempt to operate this unit if the power cord has been frayed or broken.
  • Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
  • Disconnect from the main power before making any type of connection.
  • Do not remove the cover under any conditions. There are no user-serviceable parts inside.
  • Never operate this unit when its cover is removed.
  • Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
  • Do not attempt to operate this unit if it becomes damaged.
  • This unit is intended for indoor use only, use of this product outdoors voids all warranties.
  • Always mount this unit in a safe and stable matter.
  • Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.
  • Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 20 for cleaning details.
  • Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
  • The fixture should be serviced by qualified service personnel when:
    A. Objects have fallen, or liquid has been spilled into the appliance.
    B. The appliance has been exposed to rain or water.
    C. The appliance does not appear to operate normally or exhibits a marked change in performance.

DMX Set Up

Power Supply: The ADJ Par Z100 3K contains an automatic voltage switch, which will auto-sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.

DMX-512 : DMX is short for Digital Multiplex. This is a universal pro- tool used by most lighting and controller manufacturers as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fix- ture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).

DMX Linking : DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, in the beginning, at the end, or anywhere in the middle. Therefore, the first fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.

DMX Cable Required (For DMX and Primary/Secondary

Operation) : The Par Z100 3K can be controlled via DMX-512 protocol. The Par Z100 3K has four DMX channel modes; 1 channel mode, 2 channel mode, 3 channel mode, & 4 channel mode. The DMX address is set electronically using the controls on the rear panel of the unit. Your unit and your DMX controller require an approved DMX-  512 110 Ohm Data cable for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all professional sound and lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also, remember that DMX cable must be daisy-chained and cannot be split.

Notice: Be sure to follow figures two and three when making your own cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior

Figure 2

Figure 3

XLR Pin Configuration

Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)

Special Note : Line Termination. When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR
connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibility of erratic
behavior.

Figure 4

Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.

5-Pin XLR DMX Connectors. This unit uses 5-pin DMX-512 data cables for DATA transmission. 5-pin DMX fixtures may be implemented in a 3-pin DMX line. When inserting standard 5-pin data cables into a 3-pin line a cable adaptor must be used, these adaptors are read- POWER ily available at most electric stores. The chart below details a proper cable conversion.

3-Pin XLR to 5-Pin XLR Conversion


Conductor| 3-Pin XLR Female (Out)| 5-Pin XLR Male (In)
Ground/Shield| Pin 1| Pin 1
Data Compliment (- signal)| Pin 2| Pin 2
Data True (+ signal)| Pin 3| Pin 3
Not Used| | Pin 4 – Do Not Use
Not Used| | Pin 5 – Do Not Use

System Menu

System Menu: When making adjustments press ENTER to confirm your setup then press and hold the MENU button for at least 3 seconds. To exit without making any adjustments press the MENU button. The display will lock after 30 seconds, press the MENU button for 3 seconds to unlock.

– DMX Address Setting.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, press ENTER.
  2. The current address will now be displayed and flashing.
    Press the UP or DOWN buttons to find your desired address.
    Press ENTER to set your desired DMX address.

 This will let select your desired DMX channel mode.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, and press ENTER. The current DMX channel mode will be displayed.
  2. Press the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to confirm and exit.

– This mode can be used as a precaution mode, that in case the DMX signal is lost, interrupted, or power is lost, the operating mode chosen in the setup is the running mode the fixture will go into when the DMX signal is lost. You can also set this as the operating mode you would like the unit to return to when power is applied.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, and either “BLND” or “HOLD” will be displayed beneath.

  2. Press ENTER and the bottom choice will begin to flash. Use the UP or DOWN buttons to choose an operating mode you would like the unit to start up in when power is applied or the DMX signal is lost.
    BLND (Blackout) – If the DMX signal is lost or interrupted, the unit will automatically go into standby mode.
    HOLD – If the DMX signal is lost the fixture will stay in the last DMX setting. If power is applied and this mode is set, the unit will automatically go into the last DMX set up.

  3. Press ENTER to confirm you’ve desired setup.

– This will let select your desired dimmer curve.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, and press ENTER. 1 of 6 dimmer curves will be displayed. “STDA” (standard), “STG1” (Stage 1), “TV” (TV), “ARAL” (Architectural), “THAL” (Theatre), or “STG2” (Stage 2). See the dimmer curve chart on page 18 for more info.
  2. Press the UP or DOWN buttons to find your desired dimmer curve and press ENTER to confirm and exit.

– With this function, you can adjust the dimming frequency.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, and press ENTER.
  2. Use the UP or DOWN buttons to adjust the dimming frequency between 900hz, 1000hz, 1100hz, 1200hz, 1300hz, 1400hz, 1500hz, 2500hz, 4000hz, 5000hz, 10000hz, 15000hz, 20000hz, or 250000hz.
  3. Once you have found your desired dimming frequency press ENTER to confirm.

– In this menu, you are able to make gamma corrections.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, press ENTER.
  2. Use the UP or DOWN buttons to gamma corrections.
  3. Once you have found your desired dimming frequency press ENTER to confirm.

– This function will reverse the display 180º.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, press ENTER.
  2. Press the UP button to select “DSIP” to “flip” the display, or “DISP” to revert the display to normal.
  3. Press ENTER to confirm.

– This function will allow you to manually adjust each brightness, fine dimming, and strobing. Fine dimming and strobing are only used with 3 channel mode.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, press ENTER.
  2. Use the UP and DOWN buttons to scroll through the settings. Once you have found your desired function you would like to adjust press ENTER.
  3. After you have pressed ENTER, use the UP and DOWN buttons to adjust the values. Once you have made your adjustments press ENTER to set them. Press the MENU button to exit.

– This function will run a self-test program.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, press ENTER.
  2. The fixture will now run a self-test. Press the MENU button to exit and quit the self-test.

– With this function, you can check the temperature of the fixture.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, press ENTER.
  2. The fixture temperature will now be displayed. Press MENU to exit.

– With this function, you can display the running time of the unit.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, press ENTER.
  2. The running time of the fixture will now be displayed. Press MENU to exit.

– Use this function to display the Software version of the unit.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, press ENTER.
  2. The display will show the software version.

– Use this function to reset to default settings.

  1. Press either the MENU, UP, or DOWN buttons until is displayed, and press ENTER.
  2. The display will show either “on” or “oFF”. Use the UP or DOWN buttons to choose, and press ENTER. “On” will default to factory settings. Press the MENU button to exit without change.

DMX Operation

Universal DMX Control : This function allows you to use a universal DMX-512 controller to control the dimmer, fine dimmer, strobe, and dimmer curve. A DMX controller allows you to create unique pro-grams tailored to your individual needs.

  1. The Par Z100 3K has 4 DMX channel modes; 1 channel mode, 2 channel mode, 3 channel mode, 4 channel mode. See pages 16-17 for a detailed description of the DMX values and traits.
  2. To control your fixture in DMX mode, follow the set-up procedures on pages 5-7 as well as the set-up specifications that are included with your DMX controller.
  3. Use the controller’s faders to control the various DMX fixture traits.
  4. This will allow you to create your own programs.
  5. Follow the instructions on page 9 to select your DMX channel mode and set your desired DMX address.
  6. For longer cable runs (more than 100 feet) use a terminator on the last fixture.
  7. For help operating in DMX mode consult the manual included with your DMX controller.

Beam Angle Adjustment

To adjust the beam angle slide the beam angle adjuster located inside/in front of the lens. See diagram below.
The beam angle can be adjusted manually, between 9°/ 15°/ 20°/25°/ 30°.

1 Channel Mode

Channel| Value|

Function

---|---|---
1| 0 – 255| DIMMER 0% – 100%

2 Channel Mode

Channel

| Value|

Function

---|---|---
1| 0 – 255| DIMMER 0% – 100%
2| 0 – 31
32 – 63
64 – 95
96 – 127
128 – 159
160 – 191
192 – 223
224 – 255| SHUTTER/STROBE
LED OFF
LED ON STROBING
SLOW – FAST
LED ON PULSE EFFECT
LED ON
RANDOM STROBE SLOW – FAST
LED ON

3 Channel Mode

Channel

| Value|

Function

---|---|---
1| 0 – 255| DIMMER 0% – 100%
2| 0 – 255| DIMMING FINENESS
3| 0 – 31
32 – 63
64 – 95
96 – 127
128 – 159
160 – 191
192 – 223
224 – 255| SHUTTER/STROBE
LED OFF
LED ON STROBING
SLOW – FAST
LED ON PULSE EFFECT
LED ON
RANDOM STROBE
SLOW – FAST
LED ON

4 Channel Mode

Channel

| Value|

Function

---|---|---
1| 0 – 255| DIMMER 0% – 100%
2| 0 – 255| DIMMING FINENESS
3| 0 – 31
32 – 6
64 – 95
96 – 127
128 – 159
160 – 191
192 – 223
224 – 255| SHUTTER/STROBE
LED OFF
LED ON STROBING
SLOW – FAST
LED ON PULSE EFFECT
LED ON
RANDOM STROBE SLOW – FAST
LED ON
4| 0 – 20
21 – 40
41 – 60
61 – 80
81 – 100
101 – 120
121 – 255| DIMMER MODE
STANDARD
STAGE
TV
ARCHITECTURAL
THEATRE
STAGE 2
DEFAULT DIMMER SETTING

Dimmer Curve Chart

Dimensional Drawings

Installation

The unit should be mounted using a mounting clamp (not provided), affixing it to the mounting bracket that is provided with the unit. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. Also, always use a safety cable that can hold 12 times the weight of the unit when installing the fixture. The equipment must be installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.

Multiple Unit Power Linking
With this feature, you can connect the fixtures to one another using the powerCON input and output sockets. The quantity that can be connected is 15 fixtures maximum @ 120V and 25 fixtures maximum @ 230V. After maximum fixtures are met you will need to use a new power outlet.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO THE PAR Z100 3K AS THE POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!

Fuse Replacement

Unplug the unit from any power source it may be connected to. Once the power has been disconnected, use a Phillips head screwdriver to unscrew the fuse holder located above the power input. Remove the bad fuse and replace it with a new one, and screw the fuse holder back in.

Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirrors should be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use, we recommend cleaning on a monthly basis. Periodic cleaning will ensure longevity and crisp output.

  1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
  2. Use a brush to wipe down the cooling vents and fan grill.
  3. Clean the external optics with a glass cleaner and a soft cloth every 20 days.
  4. Clean the internal optics with a glass cleaner and a soft cloth every 30-60 days.
  5. Always be sure to dry all parts completely before plugging the unit back in.

Trouble Shooting

Trouble Shooting: Listed below are a few common problems that you may encounter, with solutions. No light output from the unit;

  1. Be sure the external fuse has not blown. The fuse is located on the rear panel of the unit.
  2. Be sure the fuse holder is completely and properly seated.

Notes

Warranty

MANUFACTURER’S LIMITED WARRANTY

A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time of service, is sought.
B. For warranty service you must obtain a Return Authorization number ( R A#) before sending back the product–please contact ADJ Products, LLC  Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to the purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintenance, cleaning, or periodic check-up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear identifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness,  are limited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product.
This warranty is the only written warranty applicable to ADJ Products, LLC Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

MANUFACTURER’S LIMITED WARRANTY PERIODS:

Lighting Products = 1-year (365 days) Limited Warranty (Such as Special Effect Lighting, Intelligent
Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
Laser Products = 1 Year (365 Days) Limited Warranty (excluding laser diodes which have a 6-month limited warranty)
L.E.D. Products = 2-year (730 days) Limited Warranty (excluding motors, PCB boards, and power supplies, which have a 1-year (365-day Limited Warranty) batteries which have a 180-day limited warranty). Only the L.E.D.s carry a 2-year warranty (excluding StarTec Series which carries a 1 Year Limited Warranty)

• ADJ DMX Controllers = 2 Year (730 Days) Limited Warranty
ADJ Products, LLC – www.adj.com – Par Z100 3K Instruction Manual Page 22

Specifications

Model:
Voltage:
LED:
Power Consumption:
Power Linking:
Dimensions:
Weight:
Beam Angle:
Fuse:
Duty Cycle:
DMX:
Control:
Color Temperature:
Working Position:
Warranty:| Par Z100 3K
100 – 240V, 50/60Hz
1 x 98W COB LED
115W
15 Fixtures Max. @ 120V
25 Fixtures Max. @ 230V
19.33”(L) x 10.82”(W) x 8.75”(H)
491 x 275 x 224mm (with Bracket)
8 Lbs. / 3.6 kgs.
9/15/20/25/30 Degrees
3.15 Amp
None
4 DMX Channel Modes: 1/2/3/4
RDM (Remote Device Management)
3000K
Any Safe, Secure Position
2 Year (730 days)
---|---

Please Note : Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
Auto-Sensing Voltage : This fixture contains an automatic volt-age switch, which will auto-sense the voltage when it is plugged into the power source.

ADJ Products, LLC
6122 S. Eastern Ave. Los Angeles, CA 90040 USA
Tel: 323-582-2650 / Fax: 323-582-2941
www.adj.com / info@americandj.com
A.D.J. Supply Europe B.V.
Junostraat 2
6468 EW Kerkrade
Netherlands
www.adj.eu / support@adjgroup.eu
Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99

Follow Us On:

facebook.com/americandj
twitter.com/americandj
youtube.com/adjlighting

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals