hama 00186438 2in1 Air Purifier and Air Humidifier Instruction Manual

June 6, 2024
Hama

hama logo

hama 00186438 2in1 Air Purifier and Air Humidifier

hama 00186438 2in1 Air Purifier and Air Humidifier

Operating Instruction

Controls and displays
  1. Air intake opening (both sides)

  2. Air sensor

  3. Air outlet opening

  4. Display and operating display

  5. Front panel

  6. Fan

  7. Holder for the front panel

  8. Handle

  9. Water tank

  10. Valve cover

  11. Storage container

  12. Stopper

  13. Covering capoperating instruction 2 Operation on the device or remote control:

  14. Humidify button: Humidifier On/Off

  15. Anion button: Ion generator On/Off – generates negatively charged ions (anions) and small amounts of ozone. This increases the cleaning performance, as the anions combine with positively charged dirt particles in the room air to form larger clusters. These can then be filtered out more easily by the internal filters.
    Warning – Ozone Do not use this function if you are sensitive to ozone, in bedrooms, in rooms where children are present and in rooms with tobacco smoke. Pets might also feel disturbed.

  16. Timing button: Running time preselectable from 1 – 8 hours

  17. Filter button: After filter change – reset button for filter change indicator

  18. Sleep button: All indicators except the Sleep indicator go out and the device operates in whisper mode to allow undisturbed sleep. Pressing Sleep again briefly activates the display so that another operating mode can be selected.

  19. Speed button: Fan speed level 1 – 2 – 3 – 4

  20. Auto button: Switching between the operating modes:
    Automatic – Manual
    Automatic: Device regulates fan speed independently according to air quality

  21. OFF/ON button: After plugging the device into a socket, the OFF/ON indicator flashes. Touch the button to start the device –
    Select the desired operating mode.

operating instruction 1

Control lamps

Sleep: lights up when Sleep mode (18) has been activated
Negative ion: lights up when the anion function has been activated via button (15)
Manual: Manual operation -Automatic (Auto) or Sleep are not selected. Fan speed can be selected via the Speed button (19).
Humidification: lights up when the humidifier function has been selected via button (14). A humidity of between 40 and 60 percent is recommended. Excessive humidity promotes mould, bacteria and mites. Increasing the humidity takes some time. Formaldehyde removal: lights up during automatic operation
Auto: Automatic mode selected via the Auto button (20). The built-in air quality sensor controls the fan speed.

Filter

Filter change indicator.Flashes when filter needs to be replaced.

  • The air purifier calculates arequired filter change according to its service life.
  • The change indicator lights up when the filter should be replaced to ensuresufficient air purification.
  • With daily use, the combi-filter should be used up after approx. 6-12 months.
  • Since the filter contains all the collected pollutants, it should only be changed outdoors and with appropriate careagainst contact contamination (gloves/respiratory protection).
  • The filter is not washable.
  • An unpleasant odour during operation may indicate that filtered substances aredecomposing in the filter (e.g. bacteria) and it needs to be replaced or ventilated in the sun.
  • Vacuum the filter and the inner housing every 1to2months to remove coarse dirt. Then place the filter outdoors in direct sunlight for approx. 3hours to dry it and eliminate any bacteria, viruses etc. that may be present through the UV rays.
  • Also hold the vacuum cleaner against the open sensor opening (2) to clean it.
  • The filter can then possibly be reused. The filter must be replaced after 1year at the latest. On the one hand, thereisarisk that it will no longer completely remove the particles mentioned from the air or that the pollutant particles already in the filter will be released again. The activated charcoal also loses its effect when unpacked.
  • After changing the filter,reset the indicator by pressing the Filter button (17) on the device.
Displays
  • Speed: Display of the set fan speed

  • PM 2.5: in μg/m³; display of measured fine dust particles with an aerodynamic diameter Ø 2.5μm (0.5 to 3.5μm).
    Typical concentrations in homes are 20 to 30 μg/m³.

  • Air Quality: After switching on the device, the display flashes until the sensor has warmed up. After that, the display visually shows the indoor air quality.
    Green stands for good quality
    Orange stands for normal quality
    Red stands for poor quality

  • If the humidity in the room is very high, condensation can form on the sensor and negatively affect the display and cause switching back and forth in automatic mode. In this case, use the air purifier with a manual speed setting.

  • Temp/Humidity: Display alternates between the indoor air temperature and humidity display.

  • Timing: Display of the running time preselected via the Timing button (16)

Water tank

Warning: Make sure that the product is disconnected from the mains.

Water tank

To remove the water tank, press the detent nose down and remove the tank at an angle (approx. 45°). Open the valve on the underside of the tank with aquarter turn to the left. Fill the tank with approx. 600 ml of tap water and replace the valve.
Insert the tank at an angle and downwards. Lock the detent nose again.

Note

  • Do not move the air purifier when thereiswater in the water tank.
  • If the machine has not been switched on for along time, clean the water tank and the water channel underneath in good time to avoid contamination.
  • One water tank filling is sufficient for approx. 8hours of air humidification.
  • Do not use fragrances or chemical additives in the water.
Cleaning the water tank and water storage container

Note

  • Ensurethat no water remains in the device.
  • Operate the humidifier function only while thereisevaporation mist present. Stop the function when the water tank is empty.
  • If the air purifier is not going to used for aprolonged period of time, remove the water tank (9) and allow it to dry along with the removed valve cover (10). When the water tank is not inserted, the storage container (11) can also dry out.
  • Check the secureclosureofthe outlet opening (12+13) at regular intervals.
  • Place the device only on solid, level and water-resistant surfaces.

The damp climate in the tank and air purifier storage container can encourage the growth of germs and bacteria in the water. Contamination in the water can lead to algae growth. It is therefore important to clean the humidifier weekly or,depending on how often it is used, every 3days.
To do this, proceed as follows:

Cleaning the water tank

  • Switch the device off and disconnect it from the power supply.
  • Remove the water tank (9).
  • Remove the valve cover (10) and rinse the water tank (9) thoroughly with lukewarm water.Ifthereare limescale deposits or slight soiling in the tank, conventional domestic washing-up liquid, universal descaler (mixed according to the manufacturer’s specifications) or e. g. 3teaspoonfuls of vinegar added to 500 ml of water can be used.
  • Then rinse the water tank (9) out thoroughly with plain water.

Cleaning the water storage container

  • On the underside of the device is an outlet opening (12+13) for the water storage container.For safety,this outlet opening (12+13) is double-sealed with acover cap (13) and astopper (12).
  • Position the device so that the cover (13) and stopper (12) can be removed in an upright state. The device must not be tipped over since this can cause water to spill out of the tank.
  • Place acatching container under the air purifier.
  • Fill the water tank with clean water.Ifthereare limescale deposits or slight soiling in the tank, conventional domestic washing-up liquid, universal descaler (mixed according to the manufacturer’s specifications) or e.g. 3teaspoonfuls of vinegar added to 500 mL of water can be used.
  • Screw the valve cover (10) tight and insert the water tank in the device so that the mixtureruns into the storage container (11) and cleans it.
  • Remove the water tank (9) again.
  • Then remove the cover cap (13) and the stopper (12) and allow the water /cleaning solution to run into the catching container underneath.
  • Repeat the process if necessary,depending on the degree of soiling.
  • Finally,rinse the storage container (11) thoroughly with plain water and allow it to dry completely.
  • Finally,rinse the water tank (9) thoroughly with plain water and allow it to dry completely with the valve cover (10) open.
  • Once fully dry,close the storage container with the stopper (12) and cover cap (13).
  • The water tank (9) can now be reinserted. The device is now ready for use.

Thank you for choosing aHama product.
Take your time and read the following instructions and information completely.Please keep these instructions in asafe place for future reference. If you sell the device, please pass these operating instructions on to the new owner.

Explanation of warning symbols and notes

Risk of electric shock
This symbol indicates a risk of electric shock from touching product parts carrying hazardous voltage.

Warning
This symbol is used to indicate safety instructions or to draw your attention to specific hazards and risks.

Note
This symbol is used to indicate additional information or important notes.

Package contents

  • 1 2in1 air purifier
  • 1 5-way filter
  • 1 remote control
  • 1 instruction manual

Safety Instructions

  • The product is intended for private, non-commercial use only.
  • The product is intended only for use inside buildings.
  • Use the product only for the intended purpose.
  • Protect the product from dirt, moisture and overheating and use it in dry rooms only.
  • Do not use the product in the immediate vicinity of heaters, other heat sources or in direct sunlight.
  • As with all electrical products, this device should be kept out of the reach of children.
  • Always pull directly on the plug when disconnecting the cable, never on the cable itself.
  • Do not operate the product outside the power limits specified in the technical data.
  • Do not use the product in areas in which electronic products arenot permitted.
  • Do not use the product in adamp environment and avoid splashing water.
  • Do not place the product near interference fields, metal frames, computers, TVs, etc. Electronic devices and window frames can negatively affect the products functionality.
  • Do not drop the product and do not expose it to any major shocks.
  • Do not modify the product in any way.Doing so voids the warranty.
  • Keep the packaging material out of the reach of children due to the risk of suffocation.
  • Dispose of packaging material immediately in accordance with the locally applicable regulations.
  • Route all cables so that thereisnorisk of tripping.
  • Do not bend or crush the cable.
  • Only use the article under moderate climatic conditions.
  • Do not spray flammable materials, such as insecticides or fragrances, around or into the device. Also, do not use it to spread these or other substances.
  • Do not operate the device in places contaminated by chemical agents, poisons, smoke, oil or explosive and other gases.
  • Do not use the device near gas-fired appliances, such as gas boilers, heaters or open fireplaces.
  • The device cannot be used as a cleaning device after fire or chemical accidents.
  • Do not cover the ventilation openings of the product and ensure sufficient ventilation of the product to avoid overheating! Firehazard!
  • The lateral distance to other objects should be at least 20cm and above the device at least 30cm.
  • Do not place any objects on the device and never use it as a resting surface.
  • Do not insert any objects into the device through the air inlet or outlet.
  • The air purifier is not asubstitute for regular ventilation or vacuum cleaning.
  • Do not use the device as a substitute for an extractor bonnet or other ventilation during cooking.
  • Only set up the device in adry,stable, level and horizontal location.
  • Do not move the device during operation and avoid all shocks or impacts to the device. Disconnect the device from the mains before changing its location.
  • Disconnect the product from the mains before changing filters, cleaning and maintenance work.
  • Do not sit or stand on the device.
  • Only use original Hama filters, item No. 00186441, as these guarantee the appropriate filter effects and do not cause any damage due to incorrect air resistance.
  • Dispose of used filters with household waste.
  • The device cannot remove carbon monoxide (CO) or radon (Rn) from the air.
  • The device is intended for domestic use only under normal operating conditions. Do not operate if there are strongly fluctuating temperature differences.
  • Do not use it in ahumid environment or in rooms with high ambient temperature or humidity,e.g. in the bathroom, toilet or kitchen.
  • Close windows and doors when operating the device to effectively clean the room air.

Risk of electric shock

  • Do not open the device or continue to operate it if it becomes damaged.
  • Do not use the product if the AC adapter,adapter cable or power cable is damaged.
  • Do not attempt to service or repair the product yourself.Leave any and all service work to qualified experts.

Warning -Batteries

  • When inserting batteries, note the correct polarity (+ and -markings) and insert the batteries accordingly. Failure to do so could result in the batteries leaking or exploding.
  • Only use batteries (or rechargeable batteries) that match the specified type.
  • Before you insert the batteries, clean the battery contacts and the polarity contacts.
  • Do not allow children to change batteries without supervision.
  • Do not mix old and new batteries, or batteries of different types or from different manufacturers.
  • Remove the batteries from products that arenot being used for an extended period (unless these arebeing kept ready for an emergency).
  • Do not short-circuit batteries.
  • Do not charge batteries.
  • Do not burn batteries.
  • Keep batteries out of the reach of children.
  • Never open, damage or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
  • Remove spent batteries from the product and dispose of them without delay.
  • Avoid storing, charging and using in extreme temperatures and at extremely low atmospheric pressures (such as at high altitudes).

Warning -Button cells

  • Do not swallow the battery. Burning hazard from hazardous substances.
  • This product contains button cells. If the button cell is swallowed, serious internal burns can occur within 2hours and ultimately lead to death.
  • Keep new and used batteries out of the reach of children.
  • If the battery compartment will no longer close securely,stop using the product and keep it away from children.
  • If you suspect that batteries have been swallowed or are in any part of the body,seek medical attention immediately.

The principle of air purification

  • Afan in the device draws in room air via the air inlets.
  • The pre-filter is located at the top of the filter system for the initial filtration of impurities. Larger particles such as dandruff, hair and dust are filtered out.
  • Afterwards, the sucked-in air flows through the Hepa 13 filter.The abbreviation HEPA stands for “High Efficiency Particulate Air”. The HEPA filter consists of avery fine fibre material. It has the ability to capture the smallest particles down to a size of between 0.1 to 0.3 μm, achieving a separation efficiency of 99.95%. Thus, it can filter bacteria (0.6 to 1.0 μm); fine dust (0.1 -10μm) and pollen (10 -100 μm) from the air.
  • The air then flows through an activated charcoal filter with the acold catalyst layer
  • It filters out formaldehyde, benzene, other gases and unpleasant odours. Activated charcoal has an excellent absorption capacity.It can deodorise, dehumidify and in some cases trap viruses and have a sterilising effect.
  • The ioniser releases negatively charged ions into the air.These combine with the positively charged dirt particles to form larger particles that can be separated more easily.
  • The filtered air is discharged into the room at the air outlet.

Start-up and operation

Inserting/changing the filter
Warning

  • Make sure that the product is disconnected from the mains.
  • Since the filter contains all the collected pollutants, it should only be changed outdoors and with appropriate care against contact contamination (gloves/respiratory protection).

The filter must be inserted before the first start-up.

To do this, proceed as follows:

  • Pull the front panel upwards away from the air intake openings with both hands.
  • Remove the used filter, if any, and dispose of it in your household waste.
  • Remove the new filter from the protective packaging and insert it into the device. The black side of the activated charcoal filter must face the device.
  • First the thick cassette is inserted into the device, then the thinner coarse filter.
  • For easier mounting, retaining tabs are attached to the upper filter ends. These must point outwards towards the front panel.
  • Place the filter at the bottom of the filter chamber and insert it using the retaining tab.
  • Replace the front panel and snap it into place.

Switching the device on/off

Warning

  • Only operate the product from an approved socket that is connected to the public power supply. The socket must be installed close to the product and must be easily accessible.
  • Disconnect the product from the power supply using the On/Off switch – if this is not available, unplug the power cord from the socket.
  • If using a multi-socket power strip, make sure that the total power consumption of all connected devices does not exceed the power strip’s maximum throughput rating.
  • If you will not be using the product for a prolonged period, disconnect it from mains power.
  • Connect the mains lead on the air filter to a properly installed socket.
  • Switch the air filter on using the OFF/ON button (16).

Care and maintenance

Note: Disconnect the device from the mains before cleaning and during prolonged periods of non-use.
Only clean this product with a slightly damp, lint-free cloth and do not use aggressive cleaning agents.
Ensure that no water is able to enter the product.
See also the “Replace Filter” section for detailed cleaning instructions.

Warranty disclaimer

Hama GmbH & Co KG assumes no liability and provides no warranty for damage resulting from improper installation/mounting, improper use of the product or from failure to observe the operating instructions and/or safety notes.

Technical data


Device dimensions:| 390 x 230 x 620 mm
Power supply:| 220-240 V
Power consumption:| 105 W
Mains frequency:| 50 Hz
CADR value:| 330 m³ /h
Suitable for rooms up to:| 28m² (Ansi/AHAM AC-1 2015) – 85m² (NRCC-54013-2011)
Anion concentration:| <5 µg/m3 according to IEC 60335- 2-65
Filter type:| Coarse, pre, Hepa (H13) and activated charcoal filter with cold catalyst layer
Weight:| 7.6kg

Recycling information

Note on environmental protection:
Following the implementation of European Directive 2012/19/EU and 2006/66/EU into the national legal systems, the following applies:
Electrical and electronic devices as well as batteries must not be disposed of with household waste. Consumers are obliged by law to return electrical and electronic devices as well as batteries to the designated public collection points or to the point of sale at the end of their service lives. Detailed information on this topic is defined in the national laws of the respective country. This presence of the above symbol on the product, operating instructions or package indicates that the product is subject to these regulations. By recycling, reusing the materials or other forms of utilising old devices/batteries, you are making an important contribution to protecting our environment.Ow

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hama User Manuals

Related Manuals