Z-Wave N4002 Mini SmartPlug Dimmer User Manual
- June 6, 2024
- Z-Wave
Table of Contents
Mini SmartPlug Dimmer
User Manual
Federal Communications Commission (FCC) Statement FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may caus harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. IC Caution: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
WARRANTY
NEW ONE Products warrants this product to be free from manufacturing defects
for a period of two years from the original date of consumer purchase. This
warranty is limited to the repair or replacement of this product only and does
not extend to consequential or incidental damage to other products that may be
used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some
states do not allow limitations on how long an implied warranty lasts or
permit the exclusion or limitation of incidental or consequential damage, so
the above limitations may not apply to you. This warranty gives you specific
rights, and you may also have other rights which vary from state to state. if
the unit should prove defective within the warranty period.
SPECIFICATIONS
Model: N4002
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHZ.
Maximum load for outlet 500W Resistive
Maximum load for the Z-Wave™ controlled outlet:
Range: Up to 100 feet line of sight between the Wireless Contr
and the closest Z-Wave™ receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
Specifications subject to change without notice due to continuing product
improvement
Website: www.nie-tech.com
WARNING
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL APPLIANCES.
OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT roller ROOM THAN THE
CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG
BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES MAY AUTOMATICALLY BE POWERED
ON DUE TO TIMED EVENT PROGRAMMING. DEPENDING UPON THE APPLIANCE, THESE
UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS
CONDITION. FOR THESE REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE
STORE THE FOLLOWING:
DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES
WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR
AUTOMATIC POWER ON CONTROL.
Introduction:
This product can be operated in any Z-WaveTM network with other Z-Wave PlusTM
certified devices from other manufacturers. All non-battery-operated nodes
within the network will act as repeaters regardless of vendor to increase the
reliability of the network. Each module is designed to act as a repeater,
which will re-transmit a radio frequency (RF) signal by routing the signal
around obstacles and radio dead spots to ensure that the signal is received at
its intended destination. N4002 is a security-enabled Z-Wave PlusTM device.
Security Enabled Z-Wave PlusTM Controller must be used in order to fully
utilize the product.
The Device Type of the N4002 is on/off power switch.
The Role Type of the N4002 is Always On Slave Role Type
Key Features:
– Remote ON/OFF control via the Z-WaveTM controller
– Manual ON/OFF control with the front panel push button
– Support Association Group and Auto Report switch status
– Support firmware upgrades via Over-the-air (need Gateways support)
– Support Scenes
Product Overview:
A. AC plug
B. Z-WaveTM controlled outlet
C. ON/OFF/PROG Push button/ Status LED
Key function description
Function 1: Press the button to turn the output ON or OFF
Function 2: Function 3: quickly press 3x Button: ADD(inclusion) (only if the
switch is not included in network)quickly press 3x Button:Remove( exclusion)
Press click Z-WaveTM button 3 times quickly, and hold for at least 10 seconds
at the third time to restore the device to the factory
(Node: Please use this procedure only when the network primary controller is
missing or otherwise inoperable.)
Function 4: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Adding Your Device To A Hub
The device support two methods of inclusion, When using a Z-Wave PlusTM
certified controller choose Network Wide Inclusion or SmartStart, Network Wide
Inclusion To A Z-WaveTM Network 1, Refer to your primary controller
instructions to process the inclusion/exclusion setup procedure. 2, When
prompted by your primary controller, click the button three times in one
second.
The device is compatible with SmartStart SmartStart enabled products can be
added into a Z-WaveTM network by scanning the Z-WaveTM QR Code found on the
top of the outlet or the back of the box with a controller providing
SmartStart inclusion.No further action is required and the SmartStart product
will be added automatically within 10 minutes of being switched on and in the
network vicinity.
QR CODE
the QR code are stuck to the side of the case, DSK is included in the QR code.
DSK The DSK code can be found on the DSK label which is attached to the
packaging box.
Command Class
Command Clas | Version | Required Security Class |
---|---|---|
Z–Wave Plus Info | V2 | none |
Switch Multilevel | V4 | highest granted |
Configuration | V4 | highest granted |
Central Scene | V3 | highest granted |
Association | V3 | highest granted |
Multi-Channel Association | V3 | highest granted |
Association Group Information | V3 | highest granted |
Transport Service | V2 | none |
Version | V3 | highest granted |
Manufacturer Specific | V2 | highest granted |
Device Reset Locally | V1 | highest granted |
Indicator | V3 | highest granted |
Powerlevel | V1 | highest granted |
Security 2 | V1 | none |
Supervision | V1 | none |
Firmware Update Meta Data | V5 | highest granted |
Z-Wave™ Configuration Parameters
You may use the below configuration parameters to change the settings of the corresponding functionality.
-
Status LED Configuration
Paramter No: 2(0x02) Size:1 Byte
Value: 00(default) Output and the LED are in a different state.
Value: 01 Output and the LED are in the same state.
Value: 02 LED Always OFF
Value: 03 LED Always ON
Value: 03 LED Always ON -
Auto Turn-Off Timer
Paramter No: 3(0x03), Size=4,
Values:0 (minutes) default;
Values: 1 – 65535 (minutes); -
Auto Turn-Off Timer
Paramter No: 5(0x05), Size=4,
Values:0 (minutes) default;
Values: 1 – 65535 (minutes); -
Restores state after power failure
Paramter No: 8(0x08) Size:1 Byte
Value: 00 Output OFF.
Value: 01 Output ON.
Value: 02 (default) The state before a power outage. -
Ramp rate(Local Button + Z-Wave™)
Paramter No: 9(0x09), Size=1,Default =1
Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s ……
Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s -
Multilevel minimum value can be set(Local Button)
Paramter No: 10(0x0A), Size=1,Default =1
Value=0 disable
Value=1
Value=2 ……
Value=99 -
Multilevel maximum value can be set(Local Button)
Paramter No: 11(0x0B), Size=1,Default =99
Value=0 disable
Value=1
Value=2 ……
Value=99 -
Double Tap Behavior—when the switch is off and quickly press the button 2 times, the switch turns on to x brightness
Paramter No: 12(0x0C), Size=1,Default =0
Value=0 enable double tap to full brightness (99)
Value=1 custom value set in parameter 18
Value=2 enable double tap to maximum brightness (turn on to the value related with parameter 11)
Value=3 disable double tap to full brightness -
Enable or Disable local / Z-Wave™ control
Paramter No: 15(0x0F) Size:1 ,Default =1
Value: 00 disable
(when paddle pressed switch will not turn light on or off BUT it will still control the light via Z-Wave™ and it will change LED indicator status and on/off/multilevel status when the paddle is pressed)
Value: 01 enable (normal operation like now)
Value: 02 disable local and Z-Wave™ control
(LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave™ control is disabled -
dimmer speed (only for local press & hold)
Paramter No: 16(0x10), Size=1,Default =5
Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s ……
Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s -
Association reports
Paramter No: 20(0x14) Size:1 ,Default =2
Value: 00 Z-Wave™ control: Multilevel report (without each level, just final level)
Manual control (short press): Basic report(without each level, just final level)
Manual control(long press & relay enable): Basic report(without each level,just final level)
Manual control(long press & relay disable): Multilevel report (each level will be reported)
Value: 01 Z-Wave™ control: Multilevel report (without each level, just final level)
Manual control (short press): Basic report(without each level, just final level)
Manual control(long press & relay enable OR disable): Basic report
Value: 02 Z-Wave™ control: Multilevel report (without each level, just final level)
Manual control (short press): Multilevel report (without each level, just final level)
Manual control (long press & relay enable): Multilevel report (without each level, just final level)
Manual control (long press & relay disable): Multilevel report (each level will be reported) -
Disabled Relay Behavior
Paramter No: 21(0x15) Size:1 ,Default =0
Value: 00 reports on/off and multilevel status when the paddle is pressed and change LED indicator status and
Parameter 15 is set to value 0 or 2 (output control disabled) according to the setting in Parameter 20
Value: 01 DON’t report on/off or multilevel status or and change LED indicator status when the paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled). -
Night Mode Brightness Level—Set the level of brightness the dimmer will turn on to when off and hold the button for 2 seconds
Paramter No: 22(0x16) Size:1 ,Default =0
Value: 00 disable function
Value: 01-99 -
LED Indicator Color
Paramter No: 23(0x17), Size=1,Default =1
Value=0 White
Value=1 Blue
Value=2 Green
Value=3 Red -
LED Indicator Brightness
Paramter No: 26(0x18), Size=1,Default =1
Value=0 Bright (100%)
Value=1 Medium (60%)
Value=2 Low (30%)
Support for Association Groups
N4002 supports 3 association groups. Group 1 supports 1 node ID,Group 2 and
Group 3 Supports maximum of 5 node ID’s Association group_1:Z-Wave PlusTM
Lifeline
Association group_1 is defaulted to associate with the primary controller
(Gateway/Hub/Controller) for N4002 Status change report, 1. N4002 will trigger
the AUTO report function if the Switch status had been changed. (ex. Switch
Multilevel Report/Indicator Report/Central Scene Notification/ Device Reset
Locally Notification)
Association group_2:basic set command on/off control When the output of the
N4002 is changed, On (0xFF) or Off (0x00). The N4002 will automatically send
out a related basic set command. On (0xFF) or Off (0x00) to its associated
group.
Association group_3:basic set command on/off controlt When the output of the
N4002 is changed, On (0xFF) or Off (0x00). The N4002 will automatically send
out a related basic set command. On (0xFF) or Off (0x00) to its associated
group.
Restoring Factory Defaults
N4002 is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be
restored to factory default settings and excluded from the network.
Manual Reset: Press click Z-WaveTM button 3 times quickly, and hold for at
least 10 seconds at the third time to restore the device to the factory
Remark: All the settings and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing
or otherwise inoperable.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>