Smart Toggle Dimmer Switch
Smart Toggle Dimmer Switch Manual
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment. This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver. Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. Consult the dealer or an experienced radio/TV
technician for help. This equipment should be installed and operated with a
minimum distance of 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
WARRANTY
Evalogik Products warrants this product to be free from manufacturing defects
for a period of two years from the original date of consumer purchase. This
warranty is limited to the repair or replacement of this product only and does
not extend to consequential or incidental damage to other products that may be
used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some
states do not allow limitations on how long an implied warranty lasts or
permit the exclusion or limitation of incidental or consequential damage, so
the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights
which vary from state to state. if the unit should prove defective within the
warranty period.
SPECIFICATIONS
Model : MS13ZS
Power: 120 VAC, 60 Hz.
Signal (Frequency) : 908.42 MHZ.
Maximum load for outlet 500W Resistive
Maximum load for the Z-Wave™ controlled outlet:
Range: Up to 100 feet line of sight between the Wireless Control Room
and the closest Z-Wave™ receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
Specifications subject to change without notice
due to continuing product improvement
Website:www.nie-tech.com
WARNING
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL APPLIANCES.
OPERATION OF THE Z-Wave™ IN DEVICE MAY BE IN A DIFFERENT ROOM THAN THE
CONTROLLED APPLIANCE, ALSO AN UNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG
BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES MAY AUTOMATICALLY BE POWERED
ON DUE TO TIMED EVENT PROGRAMMING.
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL
OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES
WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR
UNINTENTIONAL OR AUTOMATIC POWER-ON CONTROL.
Introduction:
This product can be operated in any Z-Wave network with other Z-Wave Plus™ certified devices from other manufacturers. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. Each module is designed to act as a repeater, which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination. MS11ZS is a security-enabled Z-Wave Plus™ device. Security Enabled Z-Wave Plus™ Controller must be used in order to fully utilize the product. The Device Type of the MS11ZS is an on/off power switch. The Role Type of the MS11ZS is Always On Slave Role Type
Key Features:
—Remote ON/OFF control via the Z-Wave™ controller
—Manual ON/OFF control with the front panel push button
—Support Association Group and Auto Report switch status
—Support firmware upgrades via Over-the-air (need Gateways support)
—Support Scenes
Product Overview:
A. Up Push button
B. Down Push button
C. Load1 (Black)
D. Lin (Black) – Line in
E. Nin (White) – Neutral in
F. 3-way (RED)
MS11ZS Installation Wiring Diagram
A. LINE(Hot)- Black connected to power
B. NEUTRAL-White
C. LOAD-Black connected to Lighting
D. GROUND-Green/Bare
E. TRAVELER-Red/Other only in 3-way installations
Key function description
Function 1: Press the up or down button to turn the output ON or OFF
Function 2: quickly press 3x upper paddle: ADD(inclusion) (only if the switch
is not included in network)quickly press 3x lower paddle: Remove( exclusion)
Function 3: quickly press upper paddle 6x to change Status LED Configuration
Function 4: Press and hold lower paddle for 10 seconds, then LED starts
blinking, release paddle and within 2 seconds, click lower paddle 5 times
(Node : Please use this procedure only when the network primary
controller is missing or otherwise inoperable.)
Function 5: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Function 6: Tap B(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Adding Your Device To A Hub
The device support two methods of inclusion, When using a Z-Wave Plus™
certified controller choose Network Wide Inclusion or SmartStart,
Network Wide Inclusion To A Z-Wave™ Network
1, Refer to your primary controller instructions to process the
inclusion/exclusion setup procedure.
2, When prompted by your primary controller, click the Up or Down button three
times in one second.
The device is compatible with SmartStart SmartStart enabled products can be
added into a Z-Wave network by scanning the Z-Wave™ QR Code found on the top
of the outlet or the back of the box with a controller providing SmartStart
inclusion.No further action is required and the SmartStart product will be
added automatically within 10 minutes of being switched on and in the network
vicinity.
QR CODE
the QR code is stuck to the side of the case, DSK is included in the QR code.
DSK
The DSK code can be found on the DSK label which is attached to the packaging
box.
Command Class
Command Clas | Version | Required Security Class |
---|---|---|
Z-Wave Plus Info | V2 | none |
Switch Multilevel | V4 | highest granted |
Configuration | V4 | highest granted |
Central Scene | V3 | highest granted |
Association | V3 | highest granted |
Multi-Channel Association | V3 | highest granted |
Association Group Information | V3 | highest granted |
Transport Service | V2 | none |
Version | V3 | highest granted |
Manufacturer Specific | V2 | highest granted |
Device Reset Locally | VI | highest granted |
Indicator | V3 | highest granted |
Powerlevel | VI | highest granted |
Security 2 | VI | none |
Supervision | V1 | none |
Firmware Update Meta Data | V5 | highest granted |
Z-Wave™ Configuration Parameters
You may use the below configuration parameters to change settings of the
corresponding functionality.
1: Locally Button function
1: Locally Button function Parameter No: 1(0x01)| Size:1 Byte Value: 00(default) Value: 01 Value: 02| Up Button ON, Down Button OFF
Up Button OFF, Down Button ON
Up Button ON/OFF, Down Button ON/OFF
---|---|---
2:Status LED Configuration Parameter No: 2(0x02)| Size:1 Byte Value:
00(default) Value01 Value: 02 Value: 03| Output and the LED are
in different states.
Output and the LED are in the same state.
LED Always OFF LED Always ON
3: Auto Turn-Off Timer Parameter No: 3(0x03),| Size=4,Values:0 (minutes)
default; Values: 1 – 65535 (minutes);|
5: Auto Turn-Off Timer Paramter No: 5(0x05)| Size=4 Values:0 (minutes)
default; Values: 1 – 65535 (minutes);|
8:Restores state after power failure Paramter No: 8(0x08)| 8:Restores state
after power failure Parameter No: 8(0x08)| Output OFF. Output ON.The state
before a power outage.
: Ramp rate(Local Button + Z-Wave™)Paramter No: 9(0x09)| Size=1,Value=1
Value=2| Default =1from 0x63 to 0x00 or from 0x00 to 0x63 need 1s from 0x63 to
0x00 or from 0x00 to 0x63 need 2s
.
The multilevel minimum value can be set(Local ButtonParameter No: 10(0x0A)| Size=1, Value=0 Value=1 Value=2 Value=99| ,Default =1 disable
11: Multilevel maximum value can be set(Local Button)Paramter No: 11(0x0B),|
Size=1, Value=0 Value=1 Value=2 Value=99| Default =9 Disable
12:Double Tap Behavior—when switch is off and quickly press UPPER paddle 2
times, switch turns on to x brightness Paramter No: 12(0x0C)| Size=1,D
Value=0 Value=1 Value=2 Value=3| ,Default =0 enable double tap to
full brightness (99) custom value set in parameter 18enable double tap to
maximum brightness (turn on to the value relate with parameter 11) disable
double tap to full brightness
: Enable or Disable local / Z-Wave™ control
Paramter No: 15(0x0F)
| Size:1 , Value: 00 Value: 01 Value: 02| Default =1disable(when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave™ and it will change LED indicator status and on/off/multilevel status when the paddle is pressed)enable (normal operation like now) disable local and Z-Wave™ control (LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave™ control is disabled
6: dimmer speed (only for local press & hold)
Paramter No: 16(0x10),
| Size=1,DValue=1 Value=2 .Value=99| Default =5 from 0x63 to 0x00 or
from 0x00 to 0x63 need 1sfrom 0x63 to 0x00 or from 0x00 to 0x63 need 2s from
0x63 to 0x00 or from 0x00 to 0x63 need 99s
18:Custom brightness level- In this parameter define a default Brightness
level the switch will Turn on to from main switch or Regular switch in 3-way
when
Pressed upper paddle once. Paramter No: 18(0x12)
| Size=1,Default =0 Value=0 Value=(1–99)| last brightness levelustom
brightness level
19: 3-way switch type Paramter No: 19(0x13)| Size:1 ,Default =0 Value: 00
toggle switch value: 01 toggle switch| press 1x change device status;
quickly press 2x the result depend on Par11/Par12; quickly Press 3x it
trigger dimmer in the loop Value: 02 momentary switch press 1x change
device status; quickly press 2x the result depending on Par11/Par12; hold
trigger dimmer in value: 03 momentary press 1x change device status;
quickly press 2x the result depending on Par11/Par12; hold trigger dimmer in
the loop(dimmer up/dimmer down BUT after double click to full brightness, a
hold will dim DOWN always instead of trying to increase brightness)
20: Association re Parameter No: 20(0x14| Size:1, Default =2 Value: 00
Z-Wave™ control: Multilevel report (without each level, just final level)
Manual control (short press): Basic report(without each level, just fin level
Manual control(long press & relay enable): Basic report(without each level,
just final level) Manual control(long press & relay disable): Multilevel
report (each level will be reported)| Value: 01 Z-Wave™ control: Multilevel
report (without each level, just final level)
Manual control (short press): Basic report(without each level, just final level)
Manual control(long press & relay enable OR disable): Basic report value: 02 Z-Wave™ control: Multilevel report (without each level, just final Manual control (short press): Multilevel report (without each level, just final level Manual control (long press & relay enable): Multilevel report (without each level, just final level Manual control (long press & relay disable): Multilevel report (each level will be reported)
21: Disabled Relay Behavior Parameter No: 21(0x15)| Size:1 ,Default =0Value:
00| report on/off and multilevel status when the paddle is pressed and change
LED indicator status and Parameter 15 is set to value 0 or 2 (output control
disabled) according to setting in Parameter 20 Value: 01 DON’t report
on/off or multilevel status or and change LED indicator status when the paddle
is pressed a Parameter 15 is set to value 0 or 2 (output control disabled).
2: Night Mode Brightness Level—Set the level of brightness the dimmer will
turn on to when off and lower paddle held DOWN for 2 seconds Parameter No:
22(0x16)| Size:1 ,Default = Value: 00 disable function Value: 01-99|
23: LED Indicator Color Paramter No: 23(0x17),| Size=1,Default =1 Value=0
WhiteValue=1 Blue Value=2 Green Value=3 Red|
26: LED Indicator Brightness
ParamterNo:26(0x18),
| Size=1,Default =1Value=0 Bright (100%)
Value=1 Medium (60% Value=2 Low (30%
|
27: Single Tap Behavior: when the switch is off and press UPPER paddle 1 time,
switch turns on to x brightness(Local Button Parameter No: 27(0x19)|
Size=1,Default =0Value=0 last brightness level
Value=1 custom value set in parameter 18
Value=2 maximum brightness set in parameter 11
Value=2 full 100% brightness
|
Support for Association Groups
MS11ZS supports 3 association groups. Group 1 supports 1 node ID, Group 2 and
Group 3 Supports a maximum of 5 node ID’s
Association group_1:Z-Wave™ Plus Lifeline
Association group_1 is defaulted to associate with the primary controller
(Gateway/Hub/Controller) for the S11ZS Status change report,
1. MS11ZS will trigger the AUTO report function if the Switch status had been
changed. (ex. Switch Multilevel Report/Indicator Report/Central Scene
Notification/ Device Reset Locally Notification) Association group_2:basic set
command on/off control When the output of the MS11ZS is changed, On (0xFF) or
Off (0x00). The MS11ZS will automatically send out a related basic set
command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command on/off controls When the output of the
MS11ZS is changed, On (0xFF) or Off (0x00). The MS11ZS will automatically send
out a related basic set command. On (0xFF) or Off (0x00) to its associated
group.
Restoring Factory Defaults
MS11ZS is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be
restored to factory default settings and excluded from the network.
Manual Reset: Press and hold lower paddle for 10 seconds, then LED starts
blinking, release paddle and within 2 seconds, click lower paddle 5 times
Remark: All the setting and data will be permanently deleted. Please use this
procedure only when the network primary controller is missing or otherwise
inoperable.