serenelife SLOZOGEN100 Compact Ozone Generator User Manual

June 6, 2024
serenelife

serenelife SLOZOGEN100 Compact Ozone Generator User Manual
serenelife SLOZOGEN100 Compact Ozone Generator

Caution IconCAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVCE PERSONNEL.

Usage Scenarios:
Usage Scenarios:

The Compact Ozone Generator is powerful, compact, energy effcient and attractive. It is designed to quickly and effectively remove even the worst of odors such as: smoke, smoke damage, pet odors, dirty odors, molds and more. It can be used in homes, businesses, cars, RVs and more. Read ALL instructions carefully before using this product.

WARNING
This unit is not a medical device. DO NOT stop or alter any medical theraphy programs or medications without the advise of your physician. Excessive ozone concentrations may cause mucous membrane or respiratory irritation.

OZONE GENERATOR SAFETY PRECAUTIONS

  1. Never breathe in it, if you need oxygen for medical condition, get that oxygen from your healthcare This doesn’t make excision, it modifies oxygen so our bodies use it differently and that’s not necessarily a good thing.
  2. Use the Compact Ozone Generator only in unoccupied
  3. Put some fans in the room to circulate or even in the house to circulate Open the windows, open the doors and put some extra fans in.
  4. If you’re experiencing any respiratory discomfort and you can smell it at all get out and get
  5. Do not use if you have a pre-existing respiratory condition specifically allergies asthma.

PARTS AND DESCRIPTION

FRONT SIDE

FRONT SIDE

Timer/Control Knob:

  • Turn clockwise to set the timer for timed operation up to two hours.
  • Turn counter-clockwise to hold position for continuous use.

Indicator Light: Illuminates when unit is in operation.

Handle: Portable handle for easy carrying.

BACK SIDE

FRONT SIDE

Air Filter: Removable washable air filter.
Power cord: Grounded cord. (Unless otherwise specified). DO NOT bypass ground.
Fuse Holder: House removable fuse. (Spare fuse included, 4 amp, 1.25inch)

HOW TO OPERATE

TIMER KNOB

TIMER KNOB

The Compact Ozone Generator incorporates a timer for your convenience and safety. The timer can be set for up to a total of 120 minutes. When you turn the dial to the right or clockwise you are activating the timer. If you want to set less than 20 minutes, make sure timer pass 20 minutes then turn back to yur specifed time. Turn counter clockwise the timer to “hold” position to set hold function. It make the unit run indefinitely. The Compact Ozone Generator is designed to operate in unoccupied areas only!

OFF: The ozone air purifier stops working.
HOLD: The ozone air purifier would keep operating all the time.
2H Timer: You can set the minutes you need the machine to work. It will stop after the minutes is over.

To operate the Compact Ozone Generator:

  • Close off the desired area to be
  • Remove all occupants and
  • Position the unit as close as possible to the odor
  • In such environments as motels that have individual heating and cooling systems, turn the fan on and set to re-circulate.
  • Set timer to desired time and leave the room
  • Allow 40 minutes before re-entering the treated space.
  • Return to space and ventilate area.

Recommend operating time for different room size:

100sqft

|

200sqft

|

300sqft

|

400sqft

|

500sqft

|

1000sqft

---|---|---|---|---|---

4min

|

8min

|

16min

|

32min

|

40min

|

80min

How it Works

Normal oxygen (O2) molecules with atoms of oxygen
Works Instruction

An electrical current such as lightning transforms oxygen (O2) molecules into ozone (O3), activated oxygen.
Works Instruction

The Compact Ozone Generator creates O3 in a special process that utilizes an electrical current and oxygen. O3 sanitizes by breaking down odors, micro organisms and other pollutants at their source. Nature creates O3 as a natural air cleaner in a number of ways. For example, we’ve all taken a walk after a thunderstorm and experienced the clean, fresh smell in the air. That’s O3 at work.

Normal oxygen (O2) is converted to O3, which is commonly called ozone. It reverts back to O2 in about an hour if the O3 is unused.

 For sterilization, please only use in unoccupied space.

TROUBLESHOOTING

  1. Unit is plugged in properly and turned on.

  2. Wall outlet is active.

  3. Ozone plates are clean and dry without any cracks. Clean the ozone plate about once every month. Environmental factors affect the duration of ozone output. Clean or change the ozone plates as follows if the ozone output is weak. It’s better to replace it per half year. (Contact your dealer to order a replacement)
    Pull the handle, loosen the ozone holder, and draw out the ozone plate, clean it with water or replace with a new one, make sure the plate is dry and the metal terminals contact well.
    TROUBLESHOOTING
    (Ozone plates size: 88x108x1mm)

  4. Fuse is installed properly and in good condition (to replace fuse, rotate fuse holder counterclockwise to unscrew, remove old fuse, and replace with spare). Fuse is 4 amp (1.25 inch).

  5. It’s important that the ozone air purifier be properly grounded to avoid potential shock.

  6. If the fan is still not operating or no buzzing sound is detected when operating,
    call the Service/Warranty Service number.

FEATURES

FEATURES

  • 10000 mg/h High-Capacity
  • Upgraded Ozone Plates
  • Supports High Ozone Output Powerful Oxidant
  • Easy Operation
  • Maintain Healthy Environment
  • Absorbs New House Smell
  • 120 Minutes Timer for Safety Concerns
  • Removes Tough Odors: Bacteria, Cooking Fumes, Musty Odor, Animal Smell, Smokes, and Formaldehyde
  • For Unoccupied Space Only: No Entry when Ozone Treatment in Progress
  • Applicable for Hotels, Campers, Farms, and Home Use

WHAT’S IN THE BOX

Compact Ozone Generator

TECHNICAL SPECS

  • Construction Material: Aluminum & Iron with Coating
  • Area Capacity: Up to 2,000+ sq. ft
  • Power Supply: AC 120V/60Hz, 18AWG, 63” Cord
  • Power Consumption: 110W
  • Ozone Production: 10,000 mg/h
  • Air Flow Volume: 100CFM
  • Noise: <45dB
  • Timer: 0-120 minutes (2 Hours)
  • Service Life of Unit: 20,000 Hours or 5 Years
  • Service Life of the Ozone Plate: 7,000 Hours (1 Year) Replace the Ozone Plates when the Ozone Smell is Weak
  • Product Dimensions (L x W x H) : 7.1” x 9.3” x 6.8” -inches