VK MEDI Air Steriliser 120V-V1.1 User Guide

June 6, 2024
VK MEDI

VK MED - LOGO

AIR STERILISER
USER GUIDE AND INSTRUCTIONS

VK MEDI Air Steriliser 120V-V1.1

120V-V1.1

Dear Customer
Thank you for purchasing the VK Medi Air Purifier, this is clean air technology at its best. This product is packed with power and technology to provide fast and efficient clean air. We hope that you enjoy using your new unit!
The Viruskiller technology was tested against the following major airborne viruses: Poliovirus, Influenza Virus, Adenovirus, and Coronavirus DF2 by the Institute  of Medical
Sciences, School of Medicine National  Kangwon University. Testing proves a near 100% reduction for these viruses. The results for these airborne pathogens are the same for all of the Viruskiller range.
Radic8’s Viruskiller range (Hextio, VK 401, VK 102, VK 103, and VK Medi) is not FDA-cleared /FDA-approved.

READ ALL INSTRUCTIONS BEFORE USING YOUR UNIT
When using your VK Medi, basic safety precautions should be observed, including the following:

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY

  • Use the unit only for its intended use.
  • To protect against the risk of electric shock, do not immerse any part of the system in water or in any other liquids.
  • This appliance is NOT a toy.
  • This appliance is NOT to be used by children or persons with reduced physical, sensory or mental capabilities.
  • Children should be supervised at all times.
  • Never look directly at a burning ultra-violet light, as this may permanently damage your eyes.
  • To reduce the risk of an electric shock or damage to the unit, switch them off and unplug them before cleaning or performing any maintenance to the unit.
  • Heed all warnings
  • There are no UV risks associated with the devices in use. The UV reactor chambers and fans are sealed to ensure there is no risk of harm and UV exposure. Indoor air quality sensors on the devices also highlight when the filters on units need to be cleaned and replaced.

USER GUIDE AND INSTRUCTIONS

| Warning – Indicates important safety instructions that must be followed to avoid injury.
---|---
| Caution – Indicates important information to your attention to avoid the risk of injury or damage to the unit
| Prohibited – Indicates forbidden action

INSTALLATION SAFETY

Should the unit emit smoke, unusual odors, or make any strange noises, immediately switch off the unit unplug it. Contact your distributor. No form of water or liquid should enter the unit. Should this occur, immediately switch off the unit and unplug it. Contact your distributor.VK MEDI Air
Steriliser 120V-V1.1 - unit unplug 1 Do not place any heavy objects on the power cord as this may cause a fire and/or an electric shock. Make sure the power cord is plugged firmly into the outlet. If the power is not plugged in correctly, this may cause a fire.VK MEDI Air Steriliser 120V-V1.1 - power
cord Do not touch the plug with wet hands, as this may cause serious injuries.VK MEDI Air Steriliser 120V-V1.1 - power
cord 1 Do not block the air inlet of the unit, as this will reduce the airflow and result in poor performance and damage the unit. Do not spray inflammable materials near the unit, as this is a fire hazard. Do not sit, stand or place heavy objects on the unit, as this may result in injury and/or damage to the unitVK MEDI Air Steriliser
120V-V1.1 - materials 2

Do not move the product while it is switched on. as this may cause a fire and/or an electric shock.VK MEDI Air Steriliser 120V-V1.1 - materials
3

Do not alter or modify the plug or cord of this unit as it could cause a fire or an electric shock.

Use the proper power cable and outlet, do not overload the outlets with several cords simultaneously.

Keep the product away from inflammable gases, liquids, or other combustible substances, as this could cause an explosion.

To protect against the risk of electric shock, do not immerse any part of the system in water or in any other liquids.

Do not attempt to repair or replace any part of this equipment unless it is specifically recommended in this manual. All other services should be referred to a qualified technician.

Plug the unit into a 120V AC outlet only, if unsupervised, it may cause an electric shock.

Switch the unit OFF, when cleaning a room. After cleaning, it is important to ventilate the room properly before switching the unit back ON.

Switch the unit OFF, while cooking. Oils released while cooking may reduce the life span of the sterilizer. After cooking, the room must be ventilated to remove oils. You may ow switch the unit ON to remove any smells.

Airflow must NOT be restricted or obstructed, by large items such as furniture, electronic items, or curtains.

Daily room ventilation for at least 30 minutes. The unit is designed to purify and sterilize your indoor air and will do this effectively when used correctly. Good indoor air quality also requires room ventilation. We recommend opening windows and doors or operating the air conditioning, for a least 30 minutes a day.
Position the unit at least 3 meters away from the bed, to avoid excessive cooling caused by sleeping indirect airflow. Use a dedicated power outlet. Lightning or static electricity could affect the circuit and may cause a fire or damage the unit. To avoid this, plug the unit into a dedicated,  grounded outlet

KEY PARTS AND COMPONENTS

THE UNIT

VK MEDI Air Steriliser 120V-V1.1 - KEY PARTS

VK MEDI Air Steriliser 120V-V1.1 - KEY PARTS 1

DISPLAY AND MONITORING

VK MEDI Air Steriliser 120V-V1.1 - MONITORING

Name

|

Function

---|---
Display and Monitoring| Changes the information displayed on the LED in the following order: UV Lamp Time, Current Temp, Fan Speed.
Remote Control Sensor| Point your remote control at the sensor in order to use your remote ope­rate the unit.
Reactor Replacement Alarm| When this LED turns from blue to red, it is time to replace the reactor cell.
Filter Replacement Alarm| When this LED turns from blue to red, it is time to replace the filters.
VOC’s Static Display| Discontinued
Dust Static Display| The color indicates air quality: blue – good, yellow – normal, red – poor
Timer| Sets a working time for the unit. The unit will stop after the specified time has passed.
LED ON/OFF| Hold the “lamp(‘ button down for a few seconds in order to switch the LED lights ON/OFF.
UVC ON/OFF| Turns the UVC lamps ON or OFF. (Keep this on for air sterilization, keep it off for simple air purification through the mechanical filters)
Fan Speed| Press the sup- button to increase the fan speed. Press the “down” button to decrease the speed. Fan speeds: FAN 1(Quiet), FAN 2 (Normal), FAN 3 (High Speed).
Power button ON/OFF| To switch the unit ON/Off. You will hear a beep sound.

REMOTE CONTROL

VK MEDI Air Steriliser 120V-V1.1 - REMOTE CONTROL

No

| Name|

Function

---|---|---
1)| Power ON/OFF| To switch the unit ON/Off. You will hear a beep sound.
2)| Fan Speed| Increase the fan speed. Fan speeds: FAN 1 (Quiet), FAN 2 (Normal), FAN 3 (High Speed). Decrease fan speed.
3)| Mode| Changes the information displayed on the LED in the following order: UV Lamp Time, Current Temp, Fan Speed
4)| Timer| Sets a working time for the unit. The unit will stop after the specified time has passed.
5)| LED Lamp ON/OFF| Used to switch the blue LED Lamp ON/OFF on the unit.

CLEANING AND MAINTENANCE

CLEANING THE PRE-FILTER

The plastic pre-filter is reusable. To clean it, follow this procedure:

  1.  Pull out the bottom filter case ①
  2. Remove pre-filter ② from filter case ① and separate from carbon filter ③ and HEPA filter ④.
  3. Clean the pre-filter with a vacuum cleaner.
  4. Place the filter back into the filter case.
  5. Repeat the process for the top filter case ⑤

VK MEDI Air Steriliser 120V-V1.1 - CLEANING THE PRE-
FILTER

Replacing the HEPA filter

VK MEDI Air Steriliser 120V-V1.1 - Replacing the HEPA
filter

When the Filter LED light changes to RED, it is time to replace the HEPA and Carbon filters. The HEPA and Carbon filters are not reusable and should be replaced. Please contact your distributor to purchase replacement HEPA and Carbon filters. Depending on the levels of pollution, the lifetime of the HEPA filter may be longer or shorter than the recommended use times below:

HEPA filters (hrs) 6000 Carbon filters (hrs) 6000
  1. Pull out the bottom filter case ①
  2. Separate the carbon filter ③ and HEPA filter ④ from the pre-filter ②
  3. Replace them with new filters.
  4. Place them back into the filter case.
  5. Repeat the process for the top filter case ⑤
  6. Press the UP button on the Display for at least 5 seconds, to reset the Filter timer to zero.

VK MEDI Air Steriliser 120V-V1.1 - HEPA filters
\(hrs\)

Replacing the Reactor Chamber

VK MEDI Air Steriliser 120V-V1.1 - Reactor

In order for the VK Medi to remain functional, the reactor chamber must be replaced every 8000 hours. Your unit will indicate that a change is required by displaying a “-0001”  code on the LED Display.

1. Disconnect all wires from the PCB board ①.

2. Unscrew the 4 screws holding the PCB board to the reactor cell and remove the PCB board. You will need to install this on the new reactor chamber.
3. Remove the component marked with ②, by unscrewing the 2 screws, and disconnecting it from the reactor chamber. You will need to install this on the new reactor chamber.
4. You can now remove the old reactor chamber, by unscrewing the 5 screws holding it to the main unit (marked with arrows). Make sure no wires are still connected to the main unit.
5. Next, place the new reactor chamber inside the main unit and secure it with the 5 screws.
6. Install the PCB board and the component marked with ②, and connect all the wires back. (see a diagram of all the  connections on the last page of this manual)
7. You can now switch your VK Medi back on, press and hold the down button for 14 seconds, to reset the warning timer.  Your VK Medi is ready for the next 8000 hours.

VK MEDI Air Steriliser 120V-V1.1 - still connected

ERROR MESSAGES

VK MEDI Air Steriliser 120V-V1.1 - eactor ChamberThe lifespan of the Reactor Cell is 8000 hours of use. When this time has passed, the timer on the unit will display with a minus (-). When you see this warning message, it is time to replace the Reactor Cell.

UV Lamp malfunctionVK MEDI Air Steriliser 120V-V1.1 - UV Lamp
malfunction

This is an error message that refers to a malfunction of the UV lamps. Turn the unit off and contact customer service.

Circuit overheat errorVK MEDI Air Steriliser 120V-V1.1 - Circuit overheat
error

This is an error message that refers to overheating of the circuit board. Turn the unit off and contact customer service.

Fan errorVK MEDI Air Steriliser 120V-V1.1 - Fan error

This error indicates that the fan is not working properly. Turn the unit off and contact customer service.

TROUBLESHOOTING

Before you call for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defects in workmanship or materials.

Problem

| Possible cause|

Solution

---|---|---
The product will not turn on| The plug is not properly inserted- ed in the grounded outlet.| Plug the device into a working grounded outlet.
The remote control is out of battery power| Replace the batteries according to the polarity.
The voltage of the AC outlet is too low| Make sure you plug the unit into its de bdi- cared, grounded 120 AC outlet.
Weak airflow and noise from the
product.| The pre-filter has accumulated too much dust.| Clean the pre-filter to avoid this problem Also change the HEPA filter when due.
The timer preset does not work,| The timer function has not been activated.| Set the timer, according to the instructor- lions in this manual.
The air purifying function does not work properly.| The indoor air is heavily contaminated| The room requires ventilation.
The pre-filter is blocked| Clean the pre-filter.
The HEPA filter is blocked| Replace the HEPA filter.
The room is too large for the unit| Select the right Viruskiller according to the room size.
The airflow is restricted| Make sure there is enough clearance around the product and that the air inlet and outlet of the unit are unobstructed.
A strange smell is emitted from the device.| New product odor| The antimicrobial coating of the reactor cell might release a small amount of harmless odor. It should disappear in
one to two weeks.
Moist filters| When cleaning the pre-filter with water, make sure it is completely dry before reinstalling.
The product has been used in environments with a high concentration of food odors.| Food odors are oily and can penetrate into the filter or the sterilizing module. Use proper ventilation.
The product has been used in environments with a high concentration of smoke.| In areas emitting too much smoke, the performance of the sterilizing module may be affected. Use proper ventilation.

CUSTOMER SERVICES

In this manual, you will find a card containing details of your limited warranty. Please contact your distributor if you encounter issues with your unit or to procure replacement filters or reactor chamber when these reach their end of life.
Damage or malfunction caused by negligence, abuse, unauthorized repairs or use not in accordance with the User, Guide will not be covered. All warranties are rendered void  and the cost of repair will be payable by the user in the case of damages caused by:
– putting in foreign objects (such as water, liquids, fragrance oils, toys, etc.) in or out of the unit;
– transportation or handling;
– use of products such as benzene or thinners;
– incorrect power supply or output voltage;
– breakdown or loss of part caused by unauthorized disassembling or modifications;
– repair or replacement is undertaken by unauthorized persons
– non-adherence to the instructions provided in this user guide, and as given by the local customer service center;
– careless or improper use; and
– caused by operating the product in a corrosive or moist environment.

SPECIFICATIONS

The company reserves the right to make changes to the design and specifications of the product without prior notice.

Description

|

Air Sterilizer

---|---
Brand| VIRUS KILLER
Model No| VK Medi
Max. Elec. Consumption| 340 watt
Net Weight| 55 Kg

121 Lbs

Dimensions| H 1590 x D 400 x L 510 mm H 62.6 x D 15.7 x L 20 in
Noise (dB)| 41 – 50
Airflow (CFM)| 300 – 635
UVC Lamps| 8 x 8W (253.7 nm)
TiO2 Hexagon Filters| _35 Extra large
Power cord length| 1.2 m 4 ft

PCB BOARD CONNECTIONS

VK MEDI Air Steriliser 120V-V1.1 - PCB BOARD
CONNECTIONS

VK MEDI Air Steriliser 120V-V1.1 - airflow 1

VK MEDI Air Steriliser 120V-V1.1 - FIG

Sales & Design: First Floor, Columbia Mill, Bedford Street, Bolton, BL1 4BA
Tel : +44 (0) 1204 238823,
E-mail: info@radic8.com,
Manufacturer: INBair Korea LTD
3~4F, 72, Jomaru-or 411 Beon-girl, Bucheon-si, Gyeonggi-do, South Korea
E-mail: inbair01@naver.com, www.inbair.com
Made in Korea | Designed in England

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals