TANDD RTR501B Recorder Thermo Wireless User Guide

June 6, 2024
TANDD

Wireless Thermo Recorder
RTR501B / 502B / 503B / 507B
User’s Manual

Thank you for purchasing our product.
To ensure safe and proper operation, please read this guide thoroughly before use.

Overview

The RTR501B, RTR502B, RTR503B and RTR507B are wireless data loggers designed to measure and record temperature and humidity.
Recorded data is then automatically collected by the Base Unit via wireless communication and downloaded for archive and analysis.
RTR501B / 502B / 503B / 507B require a Base Unit to carry out wireless communication. (Compatible Base Units: RTR500BC, RTR500BW, RTR500BM, RTR500DC, RTR- 500MBS-A, RTR-500, RTR-500NW/AW)
For the operation and configuration of the Base Unit, refer to the instruction manual attached to the Base Unit or the RTR500B Series Help available on T &D Website.
Wireless Thermo Recorder RTR501B / 502B / 503B / 507B is referred to as the “(data) logger” or “device” in this manual.

Package Contents

RTR501B
Internal Temp Sensor| RTR502B
Temp Sensor
TR-5106 (Included)| RTR503B
Temp-Humidity
Sensor
TR-3310 (Included)| RTR507B
High Precision
Temp-Humidity Sensor
SHB -3101 (Included)
---|---|---|---

TANDD RTR501B Recorder Thermo Wireless - Package
Contents

Common Accessories

  • Lithium Battery LS14250 (or Large Capacity Battery Kit RTR-500B1 for L type model)
  • Strap (Not included with L type model)
  • Manual Set (Warranty Included)

Part Names

TANDD RTR501B Recorder Thermo Wireless - Part Names

Battery Installation

Install the battery as shown below. The recording will start automatically with the default or previous settings.

TANDD RTR501B Recorder Thermo Wireless - Battery
Installation

Default Settings

Recording Mode Endless
Recording Interval 10 minutes
Recording Start Method Immediate Start
  • Make sure to use the proper type and size screwdriver. (Phillips head #1 screwdriver is recommended.)
  • Insert the supplied battery with the tube attached. When using a  CR2 lithium battery, the tube is not necessary.
  • Before closing the cover, check the rubber packing for dust or scratches, as they can reduce the water-resistance of the rubber.
  • Be sure to completely close the cover. Make sure not to over-tighten the screws.
  • Appropriate Tightening Torque: 20N·cm to 30N·cm (2Kgf·cm to 3Kgf·cm)

Battery Replacement

When it is time for the battery to be replaced, a battery warning mark will appear. Please change the battery as soon as possible if this mark appears.TANDD RTR501B Recorder Thermo Wireless - Battery
Replacement

If you continue to use the logger without changing the battery, the current temperature and [bAtt] will be displayed alternately and wireless communication will stop. (Recording  will continue.)

TANDD RTR501B Recorder Thermo Wireless - Battery Replacement
2

  • If the battery is further left unchanged, the display will automatically shut off and all previously recorded data will be lost.
  • Although the logger continues to work for a period after the battery has been removed, leaving the device without a battery until the LCD display goes blank will cause all recorded data to be lost.
  • After the battery installation, the battery warning mark may not disappear from the logger’s LCD for 10 to 60 minutes. This is due to the characteristic of the lithium battery and is not a malfunction of the logger or the battery.

Remote Unit Registration and Settings

Via Software and Optical Communication
Connect the Base Unit to a PC with a USB cable, and place the data logger face down to align the communication areas as shown below.

TANDD RTR501B Recorder Thermo Wireless - Remote Unit Registration and
Settings

Via Mobile App and Bluetooth® Communication
When the Base Unit is an RTR500BW or RTR500BM, it is possible to make Base Unit and Remote Unit settings from nearby mobile devices using Bluetooth.

TANDD RTR501B Recorder Thermo Wireless - Remote Unit Registration and
Settings2

How to Read the LCD Display

When being used in very hot or cold environments the display may become difficult to read. This is not a malfunction.

TANDD RTR501B Recorder Thermo Wireless - How to Read the LCD
Display

1. [REC] Mark| Shows the recording status.
ON: Recording in progress
BLINKING: Waiting for programmed start
OFF: Recording stopped
---|---
2. [ONETIME] Mark| Shows the recording mode.
ON: One Time
OFF: Endless
3. Battery Warning Mark Indicates it is time for the battery to be replaced.
4. Measurement /Message Area| Measurements or operational messages are shown here.
TANDD RTR501B Recorder Thermo Wireless - How to Read the LCD Display
2| When Recording Mode has been set to “One Time” and the logger reaches its logging capacity, recording will automatically stop and in the LCD the measurement and the word [FULL] will alternately appear.
TANDD RTR501B Recorder Thermo Wireless - How to Read the LCD Display
3| The measurement and the word [SEnd] will alternately appear when data is being sent via wireless communication to the Base Unit. The recording will continue during wireless transmission.
5. [Ir] Mark| Indicates that the logger (Remote Unit) has not been registered to the Base Unit or the wireless communication is stopped (inactive radio).
6. [COM] Mark| This indicates that the device is in Bluetooth communication.
7. Unit of Measurement Shows the unit of measurement.

Specifications

Model| RTR501 B / 501 BL| RTR502B / 502BL| RTR503B / 503BL| RTR50713 / 507BL
---|---|---|---|---
Measurement Channels| Temperature 1ch| Temperature 1ch| Temperature 1ch, Humidity 1ch| Temperature 1ch, Humidity 1ch
Sensor| Thermistor (Internal)| Thermistor| Thermistor i Polymer Resistance| Thermistor| Polymer Resistance
Measurement Range| -40 to 80°C| -60 to 155°C| 0 to 55°C| 10 to 95%RH| -25 to 70°C| 0 to 99 %RH (1)
Accuracy| Avg. ±0.5°C| Avg. ± 0.3°C
at -20 to 80°C
Avg. ±0.5°C
at -40 to -20°C, 80 to 110°C
Avg. ± 1.0°C
at -60 to -40°C, 110 to 155°C| Avg. ± 0.3°C| ±5 %RH
at 25°C, to 0%RH| ±0.3°C
at 10 to 40°C ±0.5°C
Others| ±2.5 %RH
at 15 to 35°C, 30 to 80%RH
Measurement Resolution| 0.1°C| 0.1°C| 0.1°C| 1 %RH| 0.1°C| 0.1 %RH
Responsiveness| Thermal Time Constant: Approx. 15 min.
Approx. 25 min. (L Type) Response Time (90%): Approx. 35 min.
Approx. 47 min. (L Type)| Thermal Time Constant:
Approx. 30 sec. (in air)
Approx. 4 sec. (in agitated water) Response Time (90%):
Approx. 80 sec. (in air)
Approx. 7 sec. (in agitated water)| Response Time (90%): Approx. 7 min.| Response Time (90%): Approx. 7 min.
Logging Capacity| 16,000 readings| 16,000 readings| 8,000 data sets (One data set consists
of readings for multiple channels)| 8,000 data sets (One data set consists of
readings for multiple channels)
Recording Interval| 1, 2, 5, 10, 15, 20, 30 sec. 1, 2, 5, 10, 15, 20, 30, 60 min. (Total of 15 choices)
Recording
Mode (
2)| Endless: Overwrite the oldest data when capacity is full One Time: Stop recording when capacity is full
Communication Interfaces| Short Range Wireless Communication
Frequency Range: 869.7 to 870 MHz
RF Power: 5 mW
Transmission Range: Approx. 150 meters if direct and unobstructed Bluetooth 4.2 (Bluetooth Low Energy) (3)
Optical Communication
Power| Lithium Battery LS14250 x 1
L Type: Large Capacity Battery Adaptor Kit (RTR-500B1) (
4) External Power Adaptor Kit RTR-500A2 (5)
Battery Life (
6)| Approx. 10 months, L Type: About 4 years
Dimensions| H 62 mm x W 47mm x D 19 mm, L Type: H 62 mm x W 47 mm x D 46.5 mm (excluding protrusions and sensor) Antenna length: 24 mm
Weight| Approx. 50 g, L Type: Approx. 65 g
Operating Environment| -40 to 80°C
-30 to 80°C during wireless communication
Waterproof Capacity| IP67 (immersion proof)| IP64 (splash-proof / rated for use in daily life) (7)
Compatible Base Units| RTR500BC, RTR500BW, RTR500BM
RTR-500DC, RTR-500MBS-A, RTR-500NW/AW (
8)(9) RTR-500 (9)

  1. When continually used in environments with temperatures above 60 ̊C, the accuracy of humidity measurements will decrease over time. Also, humidity cannot be measured at temperatures below -20 ̊C.

  2. Only “Endless” is available when using the RTR500BW, RTR500BM, RTR-500NW/AW, or RTR-500MBS-A as a Base Unit.

  3. Bluetooth is available when using the RTR500BW or RTR500BM as a Base Unit and making device settings in the mobile app (T&D 500B Utility).

  4. When using RTR-500B1 it is necessary to purchase a Lithium Battery (LS26500). For details, contact your local authorized distributor.

  5. RTR-500A2 should not be used with the RTR501B, as it will cause the RTR-501 to display a higher than actual temperature reading of up to 3°C.

  6. The listed battery life is based on the following usage conditions: Recording at 10 second (or longer) intervals, Current Readings Transmission every 10 minutes, and Recorded Data Trans-
    mission once a day. Battery life also varies depending on ambient temperature, radio environment, frequency of communication, etc.

  7. This is the waterproof capacity of the data logger with the sensor connected. Note that the temperature-humidity sensor is not water-resistant.

  8. A firmware update is required to an RTR500B series compatible version.

  9. A software update is required to an RTR500B series compatible version.

The specifications listed above are subject to change without notice.

T&D Corporation

tandd.com
© Copyright T&D Corporation. All rights reserved.
2021.11 16508160005 (2nd Edition) Printed on recycled paper.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals