Overview

Altronix eBridge8PCRM/16PCRM and eBridge1PCTX or eBridge1ST are CAT5 to Coax cable Ethernet adapters/ Media converters that deliver data and power over the coax cable in a PoE+ compliant format. The paired set enables fast 10/100Base-T Ethernet digital communication to be transmitted over Coax cable. eBridge8PCRM/16PCRM receiver is powered by a UL Listed limited power source, PoE midspan or endspan product, such as a NetWay8M and NetWay16M, and sends its power over the coax to the eBridge1PCTX or eBridge1ST transmitter under PoE protocol. This enables the eBridge8PCRM/16PCRM to be used in a managed manner, allowing for remote camera reset. The eBridge1PCTX or eBridge1ST, in turn, delivers that PoE+ compliant power to a PoE enabled camera or IP device. The eBridge8PCRM/16PCRM will not deliver power to non-compliant devices, thus avoiding damage to improperly connected analog cameras. These plug and play units facilitate system upgrades from analog to IP cameras/devices utilizing existing legacy Coax and eliminating the costs and labor associated with installing new network cabling. In addition, data transmission and power over the Coax is possible up to 500m in comparison to 100m Ethernet maximum distance (see Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 6). A maximum range from head end to the PoE camera/device is 700m taking into consideration that up to 100m of structured cable may be deployed at each end.

Features

Agency Listings:

  • UL 60950-1 Information Technology Equipment.
  • CE European Conformity.
  • C-Tick C-Tick compliant.

Compatible Transceivers:

  • Bridge1PCTX: PoE/PoE+ compliant transceiver.
  • Bridge1ST: PoE/PoE+ compliant mini transceiver

Input:

  • Powered by a UL Listed limited power source, PoE midspan or endspan.

Ethernet:

  • Connectivity: RJ45, auto-crossover.

  • Wire type: 4-pair CAT5 or better structured cable.

  • Distance: up to 100m.

  • Speed: 10/100BaseT, half/full duplex, auto negotiation.
    PoE compliant to IEEE 802.3af (15W) and PoE+ compliant to IEEE 802.3at (30W) delivered to camera by eBridge1PCTX or eBridge1ST. Power provided by eBridge8PCRM/16PCRM to eBridge1PCTX or eBridge1ST by PoE protocol.

  • Throughput is rated to pass 25Mbps of data at distances up to 500m. With proper headend equipment this supports Megapixel, HD720, HD1080.

Coax:

  • Distance: up to 500m (see Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 6) for power delivery of coax.
  • Connectivity: BNC, RG-59/U or similar.

LED Indicators:

  • eBridge8PCRM/16PCRM:
    Blue LED – Coax link connection.
    Green – PoE ON.
    Green – Power ON.

  • eBridge8PCRM/16PCRM, eBridge1PCTX,
    eBridge1ST:
    Yellow and Green LED (RJ45) IP Link status,
    10/100Base-T/active.

LED Indicators (cont’d):

  • eBridge1PCTX and eBridge1ST:
    Blue LED – Coax link connection.
    Green LED – PoE from eBridge8PCRM/16PCRM.
Environmental
  • Operating Temperature:
    eBridge8PCRM/16PCRM:
    – 20ºC to 49ºC (– 4ºF to 120.2ºF)

eBridge1PCTX:
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
For 30W: – 40ºC to 49ºC (– 40ºF to 120.2ºF).
eBridge1ST:
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
For 30W: – 40ºC to 65ºC (– 40ºF to 149ºF)

  • Storage Temperature:
    30ºC to 70ºC (– 22ºF to 158ºF).

  • Humidity: 20 to 85%, non-condensing.

Functions:

  • Auto detection and protection of legacy non-PoE cameras/devices.

Applications:

  • Retrofit digital IP cameras in an analog CCTV installation.
  • Works with Megapixel, HD720, HD1080 and VGA (SD) cameras (see note, pg. 3).
  • Extend Network link distance in an industrial environment over 610m (see note, pg. 3).
  • Upgrade deployed CCTV Coax to a digital network in Retail, Hospitality, Arenas, Casinos, Airports, Schools, Hospitals, Transportation, etc.

Mechanical:

  • Dimensions (H x W x D approx.):
    eBridge8PCRM/16PCRM dimensions:
    1.625” x 19.125” x 8.5” (42mm x 486mm x 216mm)
    eBridge1PCTX dimensions:
    1” x 2.5” x 4.375” (25.4mm x 63.5mm x 111.1mm).
    eBridge1ST dimensions:
    2.27” x 2.645” x 1.12” (57.7mm x 67.2mm x 28.4mm).

Installation Instructions

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. eBridge8PCRM/16PCRM is not intended to be connected to outside plant leads and should be installed indoors within the protected premises. The eBridge8PCRM/16PCRM and eBridge1PCTX are intended for indoor use only. Elevated Operating Ambient – If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.

Reduced Air Flow – Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Do not obstruct any air vents on the unit. It is recommended to leave half space above and below the unit.

Mechanical Loading – Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

Circuit Overloading – Consideration should be given to the connection of the equipment to supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring.

Appropriate consideration of equipment nameplate rating should be used when addressing this concern.

Reliable Earthing – Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).

  1. eBridge8PCRM/16PCRM installation:

  2. Attach mounting brackets to eBridge8PCRM/16PCRM unit for rack installation (Fig. 4, pg. 8).
    Affix rubber pads to eBridge8PCRM/16PCRM for shelf installation (Fig. 6, pg. 8).
    Unit should be located in proximity to ethernet switch/network, NVR or video server.
    b.Connect structured cable from ethernet midspan or endspan device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 5).

  3. Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 4).
    Connection instruction
    Connection instruction

  4. eBridge1PCTX installation:

    • Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole.
      Unit should be mounted in proximity of camera/device.

    • Connect structured cable from IP camera/device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 5).

    • Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 5).
      Installation instruction
      Altronix eBridge8PCRM 8 Port Ethernet Over Caox Receiver Installation
Guide

  5. eBridge1ST installation:

    • Secure unit to the desired mounting surface with a proper fastening device utilizing the case’s mounting hole (Fig. 3, pg. 6). Unit should be mounted in proximity of camera/device.
    • Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Fig. 2a, pg. 5).
    • Connect Coax cable from eBridge8PCRM/16PCRM to BNC tether cable marked [Coax] (Fig. 2a, pg. 5)

Note: eBridge8PCRM/16PCRM is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixelation and latency. It is advisable to pretest system if unsure.
Alternatively, frame rate and resolution may be reduced to accommodate system equipment.

Technical Specifications

Parameter Description
Connections BNC for Coax link. RJ45 for ethernet link.
Input Power Requirements Midspan or endspan port connected.
Indicators Blue:    Coax Link.

Yellow (RJ45 connector):  On – Link, Off – No Link, Blinking – Activity.

Green (RJ45 connector):    On – 100Base-TX, Off – 10Base-T.

Green: Power.

Environmental Conditions| Operating Ambient Temperature (UL60950-1): eBridge8PCRM/16PCRM:    –20ºC to 49ºC (–4ºF to 120.2ºF). eBridge1PCTX:   For 15W: –40ºC to 75ºC (–40ºF to 167ºF).

For 30W: –40ºC to 49ºC (–40ºF to 120.2ºF).

eBridge1ST:        For 15W: –40ºC to 75ºC (–40ºF to 167ºF).

For 30W: –40ºC to 65ºC (–40ºF to 149ºF). Storage Temperature:  –30ºC to 70ºC (–22ºF to 158ºF). Relative humidity: 20 to 85%, non-condensing.

Operating Altitude: –304.8 to 2,000m.

Regulatory Compliance| UL/cUL Listed for Information Technology Equipment (UL 60950-1). CE European Conformity. C-Tick compliant.
Weights (approx.)| eBridge8PCRM:  Product: 5.8 lb. (2.63 kg) | Shipping: 7.8 lb. (3.54 kg)

eBridge16PCRM: Product: 7.2 lb. (3.27 kg) | Shipping: 9.2 lb. (4.17 kg)

Multiple PoE Camera Connection

eBridge8PCRM shown. eBridge16PCRM is similar, with twice as many channels.
Camera Connection

Maximum Length of Coax Type vs. Camera Power/PoE Class

Camera Power/| RG59/U (23AWG)| RG59/U (22AWG)| RG59/U (20AWG)| RG59/U (18AWG)| RG6/U (18AWG)|
---|---|---|---|---|---|---
PoE Class|
Max. Length (meters)|
13W/0| 261| 336| 500| 500| 500|
4W/1| 500| 500| 500| 500| 500|
6.5W/2| 500| 500| 500| 500| 500|
13W/3| 261| 336| 500| 500| 500|
19W| 153| 199| 316| 500| 500|
25W| 119| 152| 240| 366| 366|

Dimension

Enclosure Dimensions (H x W x D approximate):
1.625” x 19.125” x 8.5” (42mm x 486mm x 216mm)
eBridge16PCRM shown. eBridge8PCRM is similar.
Dimension

Mounting Options

Rack Mount Installation
  1. Remove and discard factory installed screws from both sides of rack chassis (Fig. 4a).

  2. Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B)
    (included) (Fig. 4b).

  3. Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 4c).

Wall Mount Installation

  1. Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 5a).
  2. Place unit at desired location and secure with #6 size screws or larger (not included) (Fig. 5b).
    Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically.
    Wall Mount Installation
    Dotted lines indicate studs behind sheetrock.

Shelf Installation

  1. Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 6).
  2. Place unit in desired location.
    Shelf Installation
    Altronix is not responsible for any typographical errors.

Mounting Hardware (Included)

  • Two (2) mounting brackets

  • Six (6) flat head screws for mounting brackets.

  • Four (4) rubber pads.

Support

140 58th Street, Brooklyn, New York 11220 USA | 718-567-8181 | fax: 718-567-9056
website: www.altronix.com |
e-mail: [email protected] |
Lifetime Warranty
IIeBridge8PCRM/16PCRM

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals