SAFETY INFORMATION
Important notes! Be sure to keep!
Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use. Should you give this device to another person, it is vital that you also pass on these instructions for use
The thermometer contains small parts that could be swallowed by children. Do
not let children handle the thermometer
without adult supervision.
Only use the thermometer for measuring body temperature under the tongue
(oral), in the armpit (axillary) or in the
anus (rectal). Do not use the the thermometer in the ear.
Do not place the thermometer near extreme heat. There is a danger of explosion
of the battery!
The device must be tested for accuracy (calibrated) after 2 years. Please send the complete device to the service centre.
If the thermomter is not going to be used for a long period, remove the battery.
Do not shake, bend or tap the thermometer. Do not drop it. It is not shock- resistant.
Protect the device from direct sunlight, extremely high or low temperatures, high humidity, dirt and dust
Do not open up the device. If a fault occurs, please do not try to repair the
unit yourself. Discontinue further use of the
unit. Contact your dealer and only have repairs carried out by the service.
The device complies with the EN 60601-1-2 standard for electromagnetic compatibility. It is subject to particular precautions in regard to electromagnetic compatibility. Please note, that portable and mobile HF communication systems may interfere with this unit. Please check the appendix for more details on this.
WARNING! Please ensure that polythene packing is kept away from the reach of children! Risk of suffocation!
Remove/insert battery
The medisana TM 700/710 thermometer is ready to use out of the package as the battery is already pre-inserted. However, if after a certain period of operation, a battery symbol appears on the display, the battery must be replaced. To do this, pull off the cap 4 of the battery compartment and remove the battery compartment about 10 mm from the thermometer. Use a suitable tool, such as a ballpoint pen tip, to loosen the button cell battery carefully. Insert the new button cell battery with the “+” symbol pointing upwards. Slide the battery compartment back into the thermometer. Close the battery compartment again with the cap.
Change the unit of measure
You can measure the temperature in ° Celsius or in ° Fahrenheit. Please proceed as follows to select the unit of measure:
- The device has to be switched off.
- Press and hold the ON/OFF -button for approx. 4 seconds to change the current setting.
- The actual selected unit of measure ( °C or °F ) appears in the upper right corner of the display
Use
Press the ON/OFF -button to switch the unit on. All display symbols will appear shortly and a signal tone will be emitted, followed by the last measured temperature. If the temperature is below 32°C (90°F), “ Lo ” is displayed – if the temperature is above 42,9°C (109.9°F), “ Hi ” is displayed. The Medisana thermometer TM 700 / TM 710 is now ready to take a temperature reading. Position the sensor tip in oral, axillary or rectal position: ORAL READINGS : Place the sensor tip of the thermometer under the tongue and close your mouth. Breathe through your nose while taking the reading in order to avoid inaccurate results. RECTAL READINGS : Many patients find rectal measurement uncomfortable, but it delivers precise results. To quickly and reliably determine body temperature, carefully insert the sensor tip approx. 1 cm into the rectum.
ARMPIT READINGS: Wash the armpit before taking a reading. Insert the tip of the thermometer into the armpit. Lower the arm and press it lightly against the body while the reading is being taken. The thermometer will now automatically begin to take a reading. During the reading, the “°”-sign flashes constantly. After the reading, you multiple tones will be emitted for approx. 10 seconds and the measurement result will be displayed. If you continue to measure even after the signal tones have been emitted, the readings will get more accurate. If you measure the body temperature on the armpit, the measurement duration should be at least 10 minutes in order to get a reliable result. If the reading is > 37,8°C (100°F), the thermometer will indicate fever alarm by announcing mutiple beep sounds (short beeps). The thermometer will switch off automatically ten minutes after taking the reading. To prolong the life of the battery, however, you should switch off the thermometer manually by pressing the ON/OFF-button.
Cleaning and disinfection
The medisana TM 700/710 thermometer is waterproof and easy to clean and
disinfect. Before and after each measurement, clean the thermometer with a
cloth soaked in a mild alcohol solution. You can also place the thermometer in
a suitable disinfectant solution. Your specialist dealer will gladly recommend
suitable cleaning products and advise you regarding their use. Do not ever
boil the thermometer!
Instructions for disposal
Do not throw this thermometer away in ordinary household waste. Consumers are legally obliged to bring all used batteries, rechargeable or otherwise, whether they contain harmful substances or not, to a collection site in their community so that they can be transferred to the proper channels for disposal. Remove the batteries before disposing of the device. Do not throw used batteries in ordinary household waste, but instead only with other hazardous waste or at a battery collecting station at a specialist shop. Contact your local authority or dealer regarding disposal.
Technical information
The CE marking refers to the EU Directive 93/42/EEC. The design and manufacture were carried out in compliance with the following European standards: EN 80601-2-56 (Medical thermometers), EN ISO 15223, EN 60601-1 (Electrical safety for medical devices). Electro-magnetic compatibility: The device meets the requirements of EN 60601-1-2 for electromagnetic compatibility. Contact medisana to request details about these measurement data.
Warranty and repair conditions
In case of a warranty claim, please contact your specialist shop or take the thermometer directly to the service point. Should you have to return the device, please state the defect and enclose a copy of the purchase receipt or invoice.