PRODUCT INFORMATION
- This product meets the requirements regarding interference suppression on radio and TV.
- After the product has been repaired, it should function properly and has to meet the safety requirements as officially laid down at this moment.
TECHNICAL INFORMATION
- Voltage : 220 – 240 V
- Frequency : 50 – 60 Hz
- Power consumption : 1450 W
- Standby power : 1 W
- Contents reservoir : 1200 cc
- Colour setting : Dark stroke
- Sap coding : HD7860/60
OPTIONAL (accessories)
No specific issues
DISASSEMBLY- AND REASSEMBLY ADVISE
To be able to open the appliance please follow bellows steps:
- Make sure all accessories like tank, podholders, drip tray, spout, and collector are removed.
- Remove the two screws at the backside of the appliance.
- Place the appliance on it’s back and remove the front panel by unlocking the two snap locks. (see picture)
- To remove the side panels unlock the 2 snap locks at eachside and gently pull of the panels.
- Once the front and side panels are removed the inner components can be reached.
To be able to reach the inner parts of the lid assy follow below steps:
- Remove the two screws A which are holding the lid. (see picture)
- To remove the lid cover, start with unlocking the 4 snap locks B. (see picture)
- The lid cover is still fi xed with two snap locks C, which can be reached with a screwdriver from the backside of the appliance. (see pictures)
- Once the lid cover has been removed the inner parts can be reached.
- To reassembly, please follow steps backward.
REPAIR INSTRUCTION
Descaling
Descaling is an important element in Senseo maintenance. It should be done at
least once every 3 months, up to 6 times a Year
This will prolong the life of your appliance and will guarantee optimal
brewing results for a long time.
Use the correct descaling agent.
Only citric acid-based descalers are suitable for descaling the SENSEO®
machine. This type of descaler descales the appliance without damaging it. For
the correct amount, see under ‘Descaling procedure’ below. Each descaling
mixture can be used only once. After use, the descaling mixture is no longer
active.
We advise you to use the special SENSEO® Descaler
(HD7006). Read the instructions on the package of the descaling agent.
Never use a descaling agent based on mineral acids such as sulphuric acid,
hydrochloric acid, sulphamic acid and acetic acid (e.g. vinegar). These
descaling agents may damage your SENSEO® coffee machine.
- Follow the steps in the section headed “Descale the appliance” see DFU (Direction for Use manual)
Volume adjustment
The PCB circuit board makes it possible to adjust the volume output by means
of pushing the one-cup and two-cup user controls.
How to adjust the volume output:
- Be sure the boiler is fi lled properly, other wise perform fi ll procedure see DFU for instructions.
- Switch appliance on and wait until the unit is ready to brew.
- Be sure a pod holder is placed, but without a Coffee POD. (Only adjusting with plain water)
- Place a cup on the drip tray cover and push the one-cup button.
- When the appliance has fi nished it is stabilized to perform the volume adjustment.
- Empty the cup, podholder and push again for one cup setting, measure the volume output with a graduated beaker. In the table you can fi nd the requirements for the minimum / maximum volume output cc/mL values depending from the country version:
One-cup setting, Including Pod holder, water spec. (Without Coffee pod)
| Min. water cc/mL| Max. water cc/mL
France version| 104| 120
General version| 125| 141
7. Unplug the appliance from the mains.
8. Press the 1- and 2 cup button simultaneously and plug the mains on.
9. When above step succeeded the led will turn on continuously.
10. Depending if the volume has to de- or increase you have to push the one-
or two cup button.
Every time you push the 1- or 2 cup button the LED will turn off for 0.5
second (feedback to user) and the pump time will be shortened or lengthened
for 0.5 seconds depending which button was pushed.
Pushing 1 cup button pump, time will be shorten with 0.5 sec is approximately
− 3.5 cc/mL (less coffee) Pushing 2 cup button pump, time will be lengthen
with 0.5 sec is approximately + 3.5 cc/mL (more coffee) When the volume has to
increase with 10 cc for example, push the 2 cup button 3 times.
The new value will be stored when you switch the appliance off by pushing the
main switch. (LED will turn off)
11. Turn appliance on again and brew one cup, measure the volume. In case the
volume is not within specifi cation repeat steps 6 – 11.
12. End.
Automatic filling procedure
The Senseo PCB contains a automatic filling procedure software routine.
This fi ll routine is only meant for back-up.
Normally the consumer has to follow the guidelines stated in the DFU.
The filling procedure functions as follows:
-
The consumer has to fi ll the water container and has to plug the appliance on the mains.
-
When the Senseo main switch has been pushed the main switch LED will light continuously. This is only the case when the Senseo has not finished the filling procedure completely! (First use)
-
When the consumer pushes the one or two-cup button, the Senseo will start automatically the pump to fill the boiler.
-
When the boiler is filled the pump stops pumping.
(Pump time approximately 22 seconds) -
When the filling procedure has been successful the software will clear a Boiler_empty_fl ag in the Eeprom.
-
By means of this Boiler_empty_flag the system knows the boiler is fi lled or not!
-
When the Senseo is switched off or disconnected from the mains, the value of the Boiler_empty_fl ag is stored in the Eeprom chip.
Restoring the Boiler_empty_fl ag to production default:
- Some times it is needed that the boiler of the Senseo have to be emptied.
- This for instance in wintertime were the possibility exists that the boiler becomes frozen during transport e.g.
- For those occasions it is handy to restore the Boilerempty fl ag again to production default.
- Bringing the Senseo back into production status, has the benefi t the fl ush routine will be activated automatically when installed by the consumer, see topic Automatic fi lling procedure.
To SET the Boiler_empty_flag can be done by:
Keep the 1-cup button pressed while plugging in the power cord of the
appliance.
The main switch LED will blink very rapidly for approximately 1 second.
To check if the Boiler_empty_fl ag is really set, you should reconnect the
power cord a second time to the net and push the main switch.
The main switch LED should light continuously.
PARTS LIST
Pos | Service code | Description |
---|---|---|
1 | 4222 259 44210 | Padholder assy 1-cup |
Deep Black
2| 4222 259 44220| Padholder assy 2-cup
Deep Black
3| 4222 240 00460| Driptray cover
4| 4222 247 61890| Driptray
Deep Black
5| 4222 259 43280| Water container assy Translucent Dark Purple
6| 4222 259 45330| Lid-Button assy
Deep Black
7| 4222 240 01410| Slider spring
8| 4222 240 05990| Ejector pin
9| 4222 247 06810| Brew chamber seal
10| 4222 247 41920| Distribution disk
11| 4222 259 43430| PCB hall sensor lid close
12| 4222 247 61270| Spout
Deep Black
13| 4222 247 61900| Spout cover
Deep Black
14| 4222 247 61590| Decorative spout cover
15| 4222 247 61870| Left panel
Deep Black
16| 4222 247 61880| Front panel
Deep Black
17| 4222 247 61280| Collector
Deep Black
18| 4222 247 61860| Right panel
Deep Black
19| 4213 247 05250| Foot
20| 4222 247 61940| TCO cap
21| 4222 247 43690| Boiler pin cover
22| 4222 259 44270| Boiler assy TCO
V7.0 – 230 V
23| 4222 259 43310| Valve assy
HD7860
24| 4222 259 43420| PCB hall sensor water container
25| 4222 247 05130| NTC O-ring
26| 4222 259 35500| NTC assy
27| 4222 259 37240| Pump ULKA HF 230 V
~50 Hz
28| 4222 259 43330| PCB assy main
29| 4222 247 61310| Push rod
| 9965 100 47409| Epcos 470 nF X2 capacitor
31| 4222 247 61601| Housing brew chamber detection sensor
32| 4222 259 51211| Water container housing panel assy
Deep Black