GARO CV12-NPST Non-Priority Boards
Non-Priority Shower
Board CV12-NPST
Garo Shower Boards are designed to facilitate the use of two electric showers
which are being supplied from a domestic 63A single phase supply. Both showers
may continually use <3kW of power each, however, when one exceeds this power
use the Board will automatically cut the power to the second shower thus
protecting the main supply fuse. This model also includes a timer with a 5
minute and 10 minute function to limit the shower run time.
TECHNICAL DATA
- Degree of protection IP40
- Resistance to impact IK08
- Auto-extinguishing degree HB (UL94)
- Test of resistance 650° C
- Ball pressure test 70° C
According to 2006/95/CE directive and EN 61439-1 and UNE-EN 61439-3 norms on affected parts.
NOTES:
- BOTH SHOWERS MUST BE DRAWING OVER 3KW FOR LOAD RELAY TO OPERATE.
- BOTH SHOWER NEUTRALS TO BE CONNECTED TO MAIN NEUTRAL BAR
- MAINS CABLE TO BE CONNECTED TO THE BOTTOM OF 40A RCBO
- K1 – 40A 1/P CONTACTOR (SHOWER NO.1)
- K2 – 40A 1/P CONTACTOR (SHOWER NO.2
- K3 – CURRENT SENSING RELAY (SHOWER NO.1)
- K4 – CURRENT SENSING RELAY (SHOWER NO.2)
NOTE: UNITS MUST BE DRAWING AT LEAST 11-12 AMPS TO OPERATE TIMER HAS 3 FUNCTIONS – 6 MIN, 10 MIN, OFF