global sources HY369 TRV Thermostatic Radiator Valve User Manual
- June 6, 2024
- global sources
Table of Contents
HY369 TRV Thermostatic Radiator Valve User Manual
Search for ” Smart RM or Smart life ” Download the Wifi App with the following
icon.
Remark: The phone and the gateway must be connected to the same router|
After the actuator stroke detection is completed, long-press the key
combination “ ” and “ ” Activate WIFI distribution network icon is flashing
---|---
APP need to connect to gateway,then connect to device Initial
Setting
| | |
---|---|---|---
First-time open thermostat, it displays all icons for 3s| blinking. Press to
set minutes hour, week. Press, to change value. Press
to confirm.| ,
Test One. “ADA” displays. Press . If batteries, gear reducer, and valve is
fine, as shown in the picture| Test Two. Finished
! Adjustment Error(If solved errors restart by pressing )
Er1 Short route: the pin was stuck which is away from terminus 2mm
Er2 The temperature sensor is disconnected or damaged
Low battery, the icon of battery is blinking After putting batteries inside,
is on display then mean okay, if flashing, then breakdown.
Technical Data
Power: 32 AA 1.5V alkaline batteries | Maximum current:90mA |
---|---|
Working temperature::-10~60°C | Display accuracy::0.5℃ |
The default range of temperature adjustment:5~35°C | Probe sensor::NTC(10k)1% |
Range of temperature display::0~70°C | Thread size: M30*1.5 |
Insulating condition: Normal environment | Size(mm):6652100mm |
Running program: Set per 1 week as a cycle | Maximum route:4.5mm |
Displays & Buttons
NO | Explain |
---|---|
A | 7 days program 6 times period, Low battery icon Child lock **** |
B | Energy-saving mode (, comfort mode C.) |
C |
Holiday mode Manual mode , Auto mode M. BOOST mode,
D|
Clock , Manual MODE Setting temperature SET
E| Room temperature , Valve status *, Open widow detection
I:| I )Press to switch auto mode, manual mode
2 Long press 3s to access programmable mode
G| 1) Decreasing Key
- Long press to activate force close valve (display (OFF] )
H| 1) Press to set comfort mode or energy-saving mode
2) Press (:) Ci for 3s, press **** Yto set comfort mode,
again press @and press ID or ( ko set energy-saving
mode
I| I) Increasing Key
- Long press to activate force open valve (display OP)
J| | 1)Confirm function
2)BOOST is the quick heating mode, short press BOOST to open or close quick
heating mode, press exits this mode, and it will turn back to original work
state
3)Long press to unlock ( about 10min will auto-lock)
---|---|---
Function
1) Time Setting
Long press for 3s to access Time Setting. Press to switch, then press to
confirm. Press, to change minutes, hours, week. Press to confirm.
2) Holiday Mode
Press to switch into Holiday Mode. Press to confirm. Press, to change
temperature and days. Press to confirm, short press switch to manual mode or
auto model, and exit holiday mode
3) Open Window Detection
It is the default that the open window function was closed after being put
into batteries and display – – ,
And open it on advance setting A2 (once change batteries, should set it
again)
When room temperature suddenly drops into temp threshold (adjust range 5
℃-25℃), the valve closes for 15 minutes (adjust range 5-60 min). After
finishing, if the room temp is still lower than the temp threshold, it will
keep this mode.
4) Programmable Mode
P2 5+2 days programmable (Default)
Long press for 3s to access Programmable Mode. Press to switch into P (5+2
Days, 6+1 Days, 7 Days). Press to confirm.Press, to change value.
P0 Manual Programmable(Default)
Period | Default Period | Default temperature |
---|---|---|
1 | 6:00-8:00 | 20℃ |
2 | 8:00-11:30 | 15℃ |
3 | 11:30—12:30 | 15℃ |
4 | 12:30—17:30 | 15℃ |
5 | 17:30—22:00 | 20℃ |
6 | 22:00—6:00 | 15℃ |
Advanced Options
Long press for 3-5 to access Advanced Option. Press to switch into. Press to confirm. Press , to change value. After 10s will save and exit
NO| Description| Range|
Default
---|---|---|---
Al| Temperature Calibration| -9-+9°C| 0.5°C
A3| Open Window Detection| I open and set open window temperature: – – mean
closed it ,press IA ,display 5 °C,mean open it ,and setting range :5-25°C
2 Valve closing time(running time of open window): 0: 05-1: 00 (press one time ,change 5min) , after time is 0,then closed it
| 1 Temp threshold:
– – °C( Default:Close )
2 0:15 mean valve
close time
Auto be locked| 0: cancel this function 1: open this function| 0
A4| MM Temperature| 1-15°C| 5°C
AS| Max Temperature| 16-70°C| 35°C
A6| BOOST Extension
Per press , CI add 100s/time| 100s-900s| 300
A–| Valve Opening| 100 mean valve opening100% 5 mean valve opening 5%|
A8| Temperature Tolerance| 0.5-1.5°C| 1℃
A9| | Factory Default| | BOOST
Display Ao, press **** whole
|
Display Ao, press **** whole display 88 , press, press change it to 00
RISK OF ELECTRICAL SHOCK
Please arrange for a professional technician to install the product according
to drawings and instructions. Disconnect the power supply before making any
connection. Contact with components carrying hazardous voltage can cause
electrical shock.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>