global sources HY369 TRV Thermostatic Radiator Valve User Manual

June 6, 2024
global sources

HY369 TRV Thermostatic Radiator Valve User Manual

Search for ” Smart RM or Smart life ” Download the Wifi App with the following icon.
Remark: The phone and the gateway must be connected to the same router| After the actuator stroke detection is completed, long-press the key combination “ ” and “ ” Activate WIFI distribution network icon is flashing
---|---

APP  need to connect to  gateway,then  connect  to device  Initial

Setting

| | |
---|---|---|---
First-time open thermostat, it displays all icons for 3s| blinking. Press to set minutes hour, week. Press, to change value. Press
to confirm.| ,
Test One. “ADA” displays. Press . If batteries, gear reducer, and valve is fine, as shown in the picture| Test Two. Finished

! Adjustment Error(If solved errors restart by pressing )
Er1 Short route: the pin was stuck which is away from terminus 2mm
Er2 The temperature sensor is disconnected or damaged
Low battery, the icon of battery is blinking After putting batteries inside, is on display then mean okay, if flashing, then breakdown.

Technical Data

Power: 32 AA 1.5V alkaline batteries Maximum current:90mA
Working temperature::-10~60°C Display accuracy::0.5℃
The default range of temperature adjustment:5~35°C Probe sensor::NTC(10k)1%
Range of temperature display::0~70°C Thread size: M30*1.5
Insulating condition: Normal environment Size(mm):6652100mm
Running program: Set per 1 week as a cycle Maximum route:4.5mm

Displays & Buttons

NO Explain
A 7 days program 6 times period, Low battery icon   Child lock ****
B Energy-saving mode (, comfort mode C.)
C

Holiday mode Manual mode , Auto mode M. BOOST mode,
D|
Clock , Manual  MODE Setting temperature SET
E| Room temperature , Valve status *, Open widow detection
I:|  I )Press to switch auto mode, manual mode

2 Long press 3s to access programmable mode

G|   1) Decreasing Key

  1. Long press to activate force close valve (display (OFF] )

H|      1) Press to set comfort mode or energy-saving mode
                      2) Press (:) Ci for 3s, press **** Yto set comfort mode, again press @and press ID or ( ko set energy-saving mode
I|           I) Increasing Key

  1. Long press to activate force open valve (display OP)

J| | 1)Confirm function
2)BOOST is the quick heating mode, short press BOOST to open or close quick heating mode, press exits this mode, and it will turn back to original work state
3)Long press to unlock ( about 10min will auto-lock)
---|---|---

Function

1) Time Setting
Long press for 3s to access Time Setting. Press to switch, then press to confirm. Press,  to change minutes, hours, week. Press to confirm.

2) Holiday Mode
Press to switch into Holiday Mode. Press to confirm. Press,   to change temperature and days. Press to confirm, short press switch to manual mode or auto model, and exit holiday mode

3) Open Window Detection
It is the default that the open window function was closed after being put into batteries and display – – ,
And open it on advance setting A2 (once change batteries, should set it again)
When room temperature suddenly drops into temp threshold (adjust range 5 ℃-25℃), the valve closes for 15 minutes (adjust range 5-60 min). After finishing, if the room temp is still lower than the temp threshold, it will keep this mode.

4) Programmable Mode
P2 5+2 days programmable (Default)
Long press for 3s to access Programmable Mode. Press to switch into P (5+2 Days, 6+1 Days, 7 Days). Press to confirm.Press, to change value.
P0 Manual Programmable(Default)

Period Default Period Default temperature
1 6:00-8:00 20℃
2 8:00-11:30 15℃
3 11:30—12:30 15℃
4 12:30—17:30 15℃
5 17:30—22:00 20℃
6 22:00—6:00 15℃

Advanced Options

Long press for 3-5 to access Advanced Option. Press to switch into. Press to confirm. Press , to change value. After 10s will save and exit

NO| Description| Range|

Default

---|---|---|---
 Al| Temperature Calibration| -9-+9°C| 0.5°C
A3| Open Window Detection| I open and set open window temperature: – – mean closed it ,press IA ,display 5 °C,mean open it ,and setting range :5-25°C

2 Valve closing time(running time of open window): 0: 05-1: 00 (press one time ,change 5min) , after time is 0,then closed it

| 1 Temp threshold:

– – °C( Default:Close )

2 0:15 mean valve

close time

Auto be locked| 0: cancel this function 1: open this function| 0
A4| MM Temperature| 1-15°C| 5°C
AS| Max Temperature| 16-70°C| 35°C
A6| BOOST Extension
Per press , CI add 100s/time| 100s-900s| 300
A–| Valve Opening| 100 mean valve opening100% 5 mean valve opening 5%|
A8| Temperature Tolerance| 0.5-1.5°C| 1℃
A9| | Factory Default| | BOOST

Display Ao, press **** whole

|
Display Ao, press **** whole  display 88 , press, press change it to 00

RISK OF ELECTRICAL SHOCK
Please arrange for a professional technician to install the product according to drawings and instructions. Disconnect the power supply before making any connection. Contact with components carrying hazardous voltage can cause electrical shock.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

global sources User Manuals

Related Manuals