eutto Ear Otoscope with Screen User Manual

June 6, 2024
eutto

eutto Ear Otoscope with Screen User Manual
eutto Ear Otoscope with Screen

Thanks for purchasing eutto otoscope, please read all the instructions before using. eutto otoscope has a built-in screen which allows users to see real- time images, to take pictures and record videos. No extra Apps / drivers needed, this otoscope displays the inspection on its screen conveniently instead of connecting a smart phone, tablet or computer, etc.

PRECAUTIONS

  1. It is recommended to wipe the lens with alcohol cloth.
  2.  Before use, please observe the surroundings, do not use the product in the environment where someone is running, so as to avoid someone hitting your body by accident and causing ear injury.
  3.  Children are not allowed to use this product alone to avoid injury.
  4. The product has built-in rechargeable lithium battery. If it is not used frequently, please charge it once every 6 months.
  5.  During use, the temperature of the lens of the product will rise slightly (will not over 35°C), please feel free to use it.

PACKAGE CONTENTS

PACKAGE CONTENTS

What You Can Get In The Box

Otoscope *1 Alcohol Cloth * 2
User manual *1 Cleaning Cloth * 1
USB cable *1 EVA storage bag *1
Reset pin *1 Ear Pick * 2
TF Card *1 Lens Cap * 2

PRODUCT SPECIFICATIONS

Product Name Ear Otoscope With Screen
Product Model NTE600
Input Current 5V 2A
Scree Spec 178° View Angle 4.5” IPS Screen
Battery Type LIthium Battery
Battery Life 4-5H
Probe Diameter 3.9mm
Waterproof IP67 Waterproof for the Probe
LED 6*LED
Optimnm Focal Length 1-2cm
Operating Ambient Temperature 0-113°F

FAQs

  • Q1: Can I connect the computer by using the USB cable?
    A1: Definitely yes, but make sure the device was opened and with the TF card inside. After connection, get into the MenuUSB Mode- choose Card Reading Mode to check the files.

  • Q2: Can it be used for inspection when charging? Will it work normally?
    A2: Yes, it can be used. But be aware do not frequently used it in such situation, which may do damage to battery lifespan.

  • Q3: I can’t get the image of the camera, or it keeps showing no signal on the screen.
    A3: Please make sure the USB camera was connected correctly to the device before open it. Plus, if the USB camera fell apart from the body accidentally, you can try to reconnect it and wait for a few seconds. If it’s still showing no signal, you can shut down the device and opened it again. Or turn to reset function for the fastest response

Quick Overview of Your New Otoscope!

Mobile Button

Control the fill light on / off with the Button

Turn on the device by Holding the Button

Mobile Button
To start video record, please Hold the Button

To take a photo or end the video record, please Click the Button

Mobile Button

For more settings, enter the menu with Button

To adjust the lights of the camera, move the cursor in the menu, or switch to previous/ next files in the album, please Click the or Button

To confirm choices in the menu, please Click the Button

To open/ close the album (required TF card inside) please Hold the Button

Product Overview

To rotate the image 180°, please Hold the Button

TF Card Slot: Support up to 32G TF card

Reset Slot: Click to reset your device

Micro USB Charging Slot: Plug& charge your device with the Micro USB cable

Connecting Slot of the USB camera

FCC Requirement

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1.  This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operatio

Note:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help

Customer Support

Manufacturer:

SHENZHEN DEEPSEA EXCELLENCE TECHNOLOGY CO . , LTD

Address:
Fourth Layers, 4 Building, Jinhua hair Industrial Park, Sanlian community, Longhua District Longhua Street, Shenzhen, Guangdong, CHINA

E-mail:
US: support@eutto.com
UK: support.uk@eutto.com
JP: support.jp@eutto.com

Facebook:
@Eutto Official Official Website:
www.eutto.com

Logo Icon

FDA No.10061092 Made in China

eutto Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals