COOL center CoolLocker User Manual
- October 27, 2023
- COOL CENTER
Table of Contents
COOL center CoolLocker User Manual
Important safety instructions
- To obtain full use of the cabinet, we recommend reading this instruction manual.
- It is the user’s responsibility to operate the appliance in accordance with the instructions given.
- Contact your dealer immediately in case of any malfunctions.
- Place the cabinet in a dry and ventilated place.
- Keep the cabinet away from strongly heat-emitting sources and do not expose it to direct sunlight.
- Always keep in mind that all electrical devices are sources of potential danger.
- Do not store inflammable material such as thinner, gasoline etc. in the cabinet.
- We declare that no asbestos nor any CFC are used in the construction.
Electrical connecting
The cabinet operates on 230 V/50 Hz.
Unit is equipped with 3 m long connecting cable. The wall socket should be
easily accessible. Never use extension cord.
All earthing requirements stipulated by the local electricity authorities must be observed. The cabinet plug and wall socket should then give correct earthing. If in doubt, contact your supplier or authorized electrician.
Unit can be connected to a normal socket with 10A or 16 A fuse.
All electrical connections must be done by a skilled electrician.
Installation and Start-up of the cabinet
Note min. installation space!
this cooler can be integrated into a wall, but in order cooling system to work
without problems at least 30 mm space must be left above the unit to enable
warm air to flow out.
Before use, we recommend that the cabinet is cleaned, see the section on
maintenance and cleaning.
Thermostat
Unit is equipped with electronical thermostat. Electronical thermostat panel is located behind the bottom frontal panel. To have access on thermostat, bottom grille should be removed by using a screw driver, see fig. 2.0
ADJUSTING TEMPERATURE
Electronic temperature control unit
- Light switch (not in use in this specific model)
- Snowflake / defrost-button
- SET-button
- Temperature setting up/down
- Power switch (turns off the compressor) Does not work as a main switch!
Temperature can be changed as follows
-
Press “SET” button until “°C” starts to blink.
-
Choose the desired temperature by pressing up or down button.
New temperature is saved automatically. -
The display returns automatically showing cooler inner temperature.
-
It takes some time to reach the desired temperature.
-
New temperature appears on the panel when it is reached.
During the automatic defrost, snowflake icon appears on the screen.
This is a fully automatic operation and does not require any action from the
user.
Factory setting for the temperature is +5°C and difference 3 degrees.
Defrosting
The cabinet defrosts automatically. Defrosted water runs to a container placed in the compressor compartment and evaporates.
Maintenance and cleaning
When starting any maintenance, always remove plug from the socket.
The cabinet must be periodically cleaned. Clean the external and internal
surfaces of the cabinet with a light soap solution and subsequently wipe dry.
Do NOT use cleansers containing chlorine or other harsh cleansers, as these can damage the surfaces and the internal cooling system.
IMPORTANT!
Clean the condenser and the compressor compartment using a vacuum cleaner and
a stiff brush. Pull out the unit from its place and clean by removing its
backside plate. Looking the unit backside condenser is located on left side.
By regular condenser cleaning you can improve cooler´s cooling efficiency and
prolong it´s lifetime remarkably.
PIC 3:
WIRE CONDENSER IS LOCATED ON THE COOLER BACK WALL Do NOT hose the compressor
compartment with water as this can cause short circuits and damage on the
electrical parts.
Service
The cooling system is a hermetically sealed system and does not require
supervision, only cleaning.
If the cabinet fails to cool, check if the reason is a power shortcut.
If you cannot locate the reason for the failure, please contact your supplier.
Please inform model /type and serial number of the cabinet. You can find this
information on the product label, which is placed behind the bottom grille,
next to electronic thermostat, see pic 4.
Disposal
Disposal of the cabinet must take place in an environmentally correct way. Please note existing regulation on disposal. There may be special requirements and conditions which must be observed. Costs of recycling WEEE-waste are covered by the supplier and unit can be scrapped as WEEE-without costs.
Manufactured by:
Coolcenter Forssa Oy
Sipilänkatu 11
30100 FORSSA, Finland
www.coolcenter.fi