Unpacking and moving the package
The rims are removed, the film and cardboard corners are removed. The product
can be tilted to the side of the handle when taking off the base (be careful
not to open the door). Transfer to its place (with hand truck). The product
has wheels underneath, so you can move it on a flat surface. By tightening the
adjusting legs on the front edge of the product, the cabinet remains in place.
If the product must be tilted horizontally during transport, the product must
be in an upright position 2 h before starting.
Important safety instructions
- To obtain full use of the cabinet, we recommend reading this instruction manual.
- The user’s responsibility is to operate the appliance in accordance with the instructions given.
- Contact your dealer immediately in case of any malfunctions.
- Place the cabinet in a dry and ventilated place.
- Keep the cabinet away from strongly heat-emitting sources and do not expose it to direct sunlight.
- Always keep in mind that all electrical devices are sources of potential danger.
- Do not store inflammable material such as thinner, gasoline etc. in the cabinet.
- We declare that no asbestos nor any CFC are used in the construction.
Electrical connecting
The cabinet operates on 230 V/50 Hz.
Unit is equipped with 5 m long connecting cable. The wall socket should be
easily accessible. Never use extension cord.
All earthing requirements stipulated by the local electricity authorities must
be observed. The cabinet plug and wall socket should then give correct
earthing. If in doubt, contact your supplier or authorized electrician.
Unit can be connected to a normal socket with 16 A fuse.
All electrical connections must be done by a skilled electrician.
Installation and Start-up of the cabinet
Note min. installation space!
this cooler can be integrated into a wall, but in order cooling system to work
without problems at least 50 mm space must be left above the unit to enable
warm air to flow out.
It is recommended to clean the cabinet before use. (See the section on
maintenance and cleaning.)
Thermostat
Unit is equipped with electronical thermostat. Electronical thermostat is
located behind the bottom frontal grille. To have access on thermostat, bottom
grille should be removed by using a screwdriver, see fig. 2.0
ADJUSTING TEMPERATURE
Electronic temperature control unit
- Light switch (not in use in this specific model)
- Snowflake / defrost-button
- SET-button
- Temperature setting up/down
- Power switch (turns off the compressor) Note! Power switch does not work as a main switch!
Temperature can be changed as follows
- Press “SET” button until “°C” starts to blink.
- Choose the desired temperature by pressing up or down button. New temperature is saved automatically.
- The display returns automatically showing inner temperature of cooler.
- It takes some time to reach the desired temperature.
- New temperature changes on the panel when it is reached.
During the automatic defrost, orange defrost- icon starts to blink and display
shows the temperature.
This is a fully automatic operation and does not require any action from the
user.
Factory setting for the temperature is +5°C and difference 3 degrees.
Defrosting
The cabinet defrosts automatically. Defrosted water runs to a container
placed in the compressor compartment and evaporates.
Maintenance and cleaning
When starting any maintenance, always remove plug from the socket.
The cabinet must be periodically cleaned. Clean the external and internal
surfaces of the cabinet with a light soap solution and subsequently wipe dry.
Do NOT use cleansers containing chlorine or other harsh cleansers, as these
can damage the surfaces andthe internal cooling system.
IMPORTANT!
Clean the condenser and compressor compartment of the refrigeration unit
regularly, at least once a year by vacuuming and using a light brush, more
often depending on the conditions. Pull out the unit from its place and clean
by removing its backside plate. Looking the unit backside condenser is located
on left side. By regular condenser cleaning you can improve cooler´s cooling
efficiency and prolong it´s lifetime remarkably.
PIC 3:
WIRE CONDENSER IS LOCATED ON THE COOLER BACK WALL
Do NOT hose the compressor compartment with water as this can cause short
circuits and damage on the electrical parts.
Service
The cooling system is a hermetically sealed system and does not require
supervision, only cleaning.
If the cabinet fails to cool, check if the reason is a power shortcut.
If you cannot locate the reason for the failure, please contact the
manufacturer’s maintenance. Please inform model /type and serial number of the
cabinet. You can find this information on the product label, which is placed
behind the bottom grille, next to electronic thermostat, see pic 4.
Disposal
**** Disposal of the cabinet must take place in an environmentally correct
way. Please note existing regulation on disposal. There may be special
requirements and conditions which must be observed.
Costs of recycling WEEE-waste are covered by the supplier and unit can be