COOL CENTER CoolCellar 100 6D Lockers User Manual
- June 13, 2024
- COOL CENTER
Table of Contents
User manual
CoolCellar 100 6D
CoolCellar 100 2D
IMPORTANT SAFETY INSTRUCTIONS
- To obtain full use of the cabinet, we recommend reading this instruction manual.
- The user’s responsibility is to operate the appliance in accordance with the instructions given.
- Contact your dealer immediately in case of any malfunctions.
- Place the cabinet in a dry and ventilated place.
- Keep the cabinet away from strongly heat-emitting sources and do not expose it to direct sunlight.
- Always keep in mind that all electrical devices are sources of potential danger.
- Do not store inflammable material such as thinner, gasoline etc. in the cabinet.
- We declare that no CFC is used in the construction.
INTENDED USE
The device is designed for cold storage of products. It consists of two
separate parts:
– lockers (bottom)
– refrigeration unit (top)
ELECTRICAL CONNECTING
The cabinet operates on 230 V/50 Hz.
Unit is equipped with 3 m long connecting cable. The wall socket should be
easily accessible. Never use extension cord.
Unit can be connected to a normal grounded socket. Fuse min. 10 A.
INSTALLATION AND START-UP OF THE CABINET
The manufacturer’s responsibility is the installation of the product (unless
otherwise agreed). The customer is responsible for preparing the installation
site and should have received an installation drawing from the manufacturer to
prepare the installation site. All electrical work at the installation site
must be carried out by an authorized electrician.
The installation drawing includes instructions for
– the number of grounded sockets to be installed
– location of the sockets
– required size of the fuse
– minimum installation distances required for air circulation (above and
behind)
– theoretical heat load W / day of equipment
Before use, the manufacturer recommends that the cabinet is cleaned. See the
section on maintenance and cleaning.
Refrigeration unit always produces heat while operating. This is normal
operation of the equipment.
ADJUSTING TEMPERATURE
Unit is equipped with electronical thermostat. In addition, the device is
equipped with a digital temperature display. Manufacturer has set the device
at +5°C.
All the lockers of the device operate at the same temperature. It is not
possible to set different temperature per locker.
The temperature control panel (electronical thermostat) is located at the top
of the equipment, behind the front panel, picture 1. An additional display is
located at the lower corner of the front panel.
Electronic temperature control unit (Dixell XR77CX)
PICTURE 2: ELECTRONICAL THERMOSTAT DIXELL XR77CX
Temperature can be adjusted as follows:
-
Press “SET” button until “°C” starts to blink.
-
Choose the desired temperature by pressing up or down button.
New temperature is saved automatically. -
The display returns automatically showing inner temperature of the cooler.
-
It takes some time to reach the desired temperature.
-
New temperature changes on the panel when it is reached.
During the automatic defrost, snowflake icon appears on the screen (see
picture 2, button 2).
This is a fully automatic operation and does not require any action from the
user.
Factory setting for the temperature is +5°C and maximum difference 3 degrees.
DEFROSTING
The cabinet defrosts automatically. Defrosted water runs to a container located under the device and evaporates.
MAINTENANCE AND CLEANING
Never cover the top or bottom air circulation panels of the equipment.
When starting maintenance operations, always unplug the device first.
The lockers must be cleaned regularly. Clean the inner and outer surface of
the lockers with mild cleaner and dry them. Don’t use any cleaners containing
chlorite or other strong cleaning agents, as they might damage surfaces.
IMPORTANT! The condenser in the refrigerating system of the equipment
must be cleaned of dust regularly. Regular cleaning of condenser increases the
operating lifetime of the device, as well as improves refrigeration capacity.
In case scheduled maintenance program is applicable, the manufacturer is
responsible for the cleaning of the condenser at necessary intervals.
The condenser is in the compressor compartment behind the front panel.
Clean the condenser at least once a year by vacuuming and using a brush
lightly, more often depending on the conditions. Be careful not to damage the
thin lamels of the condenser!
Never splash the compressor with water, as this may cause short circuits and
damage electrical parts.
SERVICE
The cooling system is a hermetically sealed system and does not require
supervision.
If the equipment fails to cool, check if the reason is a power shortcut.
If you cannot locate the reason for the failure, please contact manufacturer’s
maintenance. Please inform model /type and serial number of the cabinet. You
can find this information on the product label, which is placed behind the top
panel, next to electronic thermostat, see pic 4.
DISPOSAL
Disposal of the refrigeration equipment must be carried out in accordance with
the Regulation on the Decommissioning of Electrical and Electronic Equipment
(WEEE).
This equipment can be delivered to the WEEE waste recycling centre free of
charge.
TECHNICAL INFORMATION
Height | 2040 – 2078 mm |
---|---|
Width | 1078 mm |
Depth | 688 mm |
Voltage | 230 V / 50 Hz |
Temperature range | +4°C…+10°C |
Input power | 405 W |
Refrigerant | R290 (propane) |
Weight (net) | 210 kg |
Gross/Net volume of locker | CoolCellar 100 6D 6pcs 129 / 106 l |
CoolCellar 100 2D 2pcs 387 / 365 l
Temperature classification| 3 (max. +25 °C / 60% relative humidity)
MANUFACTURED BY