Ring Keypad Z-Wave User Manual

June 6, 2024
Ring

Keypad Z-Wave
Technical Manual


Ring Keypad

Adding Keypad to a Z-Wave Network
Ring Keypad can be added via smart start or via classic inclusion mode –
Smart Start Inclusion Steps:

  1. Initiate add keypad flow in the Ring Alarm mobile application – Follow the guided add flow instructions provided in the application
  2. Scan the QR code found on the package of the keypad or the QR code found on the back of the keypad
  3. Plugin the keypad to line power
  4. When the inclusion process is incomplete, the LED on the keypad will be solid blue, then go out.
  5. Test the Keypad. Any button presses would beep

Classic Inclusion Steps:

  1. Initiate add keypad flow in the Ring Alarm mobile application – Follow the guided add flow instructions provided in the application
  2. Select add manually and enter the 5 digit DSK pin found on the package of the keypad or the QR code found on the back of the keypad
  3. Plugin the keypad to line power
  4. Press and hold the “1” key for three seconds
  5. When the inclusion process is complete, the LED on the keypad will be solid blue, then go out.
  6. Test the Keypad. Any button presses would beep

This is a SmartStart enabled product that can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing  SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
This product can also be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.
This product is not a main-operated device.
Wake up is not supported on this device

Removing a Keypad to a Z-Wave Network

Exclusion Instructions

  1. Initiate remove keypad flow in the Ring Alarm mobile application – Select the settings icon from the device details page and choose “Remove Device”
  2. Press and hold the “1” key for three seconds
  3. When the exclusion process is incomplete, the LED on the keypad will be solid blue, then go out.
  4. Test the Keypad. Any button presses would not beep

Ring Base Station – Reset

Factory Default Instructions

  1. Press and hold the “5” key and using a pointed end of a paperclip, gently press and release the reset button via the reset pinhole found at the back of the keypad
  2. Red network LED at the top left-hand corner will start to blink rapidly
  3. Wait for the red LED to stop blinking then release the “5” key

Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.

Ring Keypad EU – Notification Information

Notification Supported Report:
Keypad supports Heat Alarm (0x04) and Home Security (0x07) and Power Management (0x08) and System (0x09).
Event Supported Report:
Heat Alarm (0x04) : Clear State (0x00), OVERHEAT_DETECTED_UNKNOWN_LOCATION (0x02)
Home Security (0x07): Motion detection (0x08), State idle (0x00)
Power Management (0x08): State idle (0x00), Power has been applied (0x01), AC mains disconnected (0x02), AC mains re-connected (0x03), Battery is charging (0x0C) System (0x09): SYSTEM_SOFTWARE_FAILURE (0x04) with 0x55

Ring Keypad EU – Association Information

Association – Lifeline
This keypad has one Association group and Max 1 node. Group 1 is a lifeline group that will receive unsolicited messages relating to entry control notifications, notifications  reports, battery report notifications, and device reset locally notifications

Ring Key EU – Configuration Information
Ring Keypad offers a wide variety of advanced configuration settings. The below parameters can be accessed from the main controller’s configuration interface.

Parameter Size Default Value/Dec Description
1 (0x01) 2 70 Battery Report Interval: Default heartbeat check in time.

Avadat: e settings: 70-1440 mins.
2 (0x02)| 1| 1| Z-Wave Sleep Timeout: Time to wait after receiving ZW for more OTA messages. Available settings: 1-5 seconds
3 (0x03)| 1| 1| Co-Prot Is Alive: Base Station check to see if the co-proc is operational. 0 = No 1 = Yes
4 (0x04)| 1| 5| Proximity Timeout : Timeout when proximity is detected and no input is received. Available settings: 0-30 seconds
5 (0x05)| 1| 5| Button Press Timeout : Timeout when a button is pressed, but a sequence is not completed and buttons are no longer being pressed Available settings: 0-30 seconds
6 (0x06)| 1| 15| Status Change Timeout: Available settings: 10-60 seconds
7 (0x07)| 1| 0| Power Mode: Set the battery power saving mode for the keypad. 0= Extended Battery Life 1=Normal Battery Life
8 (0x08)| 1| 3| Key Backlight Timeout: Timeout for keypad LED backlight to stay on between key presses. Available settings: 1-15 seconds
9 (0x09)| 1| 100| Key Backlight Brightness: Adjusts the brightness of the keypad backlight Available settings: 0-100%
10 (0x0A)| 1| 8| Key Tone Volume: Volume, Tone Time, Frequency Available settings: 0-10
I 1 (0x0B)| 1| 5| Ambient Light Sensor Level: Light threshold where keypad will stop backlighting if higher than Available settings:0-100
12 (OxOC)| 1| 6| Siren Volume: Volume to produce loudest output, Needs to be calibrated Available settings: 0-10
13 (0x0D)| 1| 1| Proximity On/OFF: Turn On and Off the Proximity Detection. 0= off 1 = on
14 (0x0E)| 1| 100| Proximity Distance: Adjusts the proximity distance (CM) If applicable to the product.
Available settings: 0-100CM
15 (0x0F)| 1| 50| Extended Battery Life LED Brightness Adjustment: Percentage of brightness for all LEDs in “Power Mode’ = Extended (needs calibration)
Available settings: 0-100%
16 (0x10)| 1| 65| Reduced Battery Life LED Brightness Adjustment: Percentage of brightness for all LEDs in Tower Modes = Reduced (needs calibration)
Available settings:0-100%
---|---|---|---
17 (0x: 1)| 1| 5| Fast Blink Rate: LSB = 0.1 sec Fast Rate Type to blink the LEDs Available settings: 1-100
18 (0x12)| 1| 2| Slow Blink Rate: LSB = 0.5 sec Slow Rate Type to blink the LEDs Available settings: 1-100
19 (0x13)| 2| 1500| Supervision Report Timeout. settings: 503-5000 millisecond
20 (0x14)| 1| 1| Number of Re-transmissions Attempts. settings: 0-5
21 (0x15)| 1| 5| Wait Period Between Re-transmissions Attempts. settings: 1-60 seconds
22 (0x16)| 1| 0 (US English)| Available settings:0-31.
Set the languages to the keypad.
Get this configuration parameter and you can know the current Language used for this Keypad
Value/Decimal| Languages
0| US English
| UK English
2| French
3| German
4| Italian
| Spanish
o| Dutch
7| Danish
| Norwegian
9| Swedish
70| Finnish
71| Arabic
72-31| Undefined
23 (0x17)| 4| –| Read Only!
Configuration Report Value:
BYTE 0|
BYTE 1|
BYTE 2|
BYTE 3| Bit mask data for supported languages. LSB format. Detail in below.
 24 (0x18)| 3| –| Read Only!
Configuration Report Value:
BYTE C| Quantity of audio files
BYTE 1| Audio file version
BYTE 2| Audio file sub version

To review your warranty coverage, please visit www.ring.com/warranty.
© 2020 Ring LLC or its affiliates.
Ring, Always Home, and all related logos are trademarks of Ring LLC or its affiliates.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals