BRISTAN GLL RAPSNK3 SF C Gallery Rapid Boiling 3-in-1 ScaleFilter Sink Mixer Chrome User Guide
- June 6, 2024
- BRISTAN
Table of Contents
- Important Safety Information
- Specification
- Prior to Installation
- Pack Contents
- Installation Requirements
- Installation
- Operation
- Operation
- General Cleaning
- Maintenance
- Maintenance Schedule
- Troubleshooting
- Troubleshooting Continued
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Installation Instructions
and User Guide
Gallery Rapid Boiling 3-in-1
ScaleFilter Sink Mixer Chrome
Models Covered:
GLL RAPSNK3 SF C
Please keep this booklet for future reference.
The installer, when you have read these instructions please ensure you leave
them with the user.
Thank you for choosing Bristan, the UK’s leading tap and shower expert.
We have designed this product to be easy to install and use. It has also been
assessed to all of the relevant British Standards and conforms to UKCA and CE
Regulations.
These instructions are for your guidance to a safe and successful.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Important Safety Information
- Please read these instructions thoroughly and retain them for future use.
- All products manufactured and supplied by Bristan are safe provided they are installed, used correctly, and receive regular maintenance in accordance with these instructions.
- If you are in any doubt about your ability to install this product safely you must employ the services of an experienced qualified plumber/electrician.
- ~~~~Warning: The Boiling Water Tank is intended for domestic use only. Do not install the unit outdoors or where it might be subjected to damp or freezing conditions.
- Check the power rating of the Boiling Water Tank is suitable for the power rating of the electrical circuit that it is being installed on
- Check that no parts are missing or damaged on the Boiling Water Tank or Tap as per the instructions. If parts are missing or damaged, do not install and contact Customer Services
- Ensure the Boiling Water Tank is installed in a room/environment with an access point. This is required to prevent condensation from forming within the unit. Keep away from direct sunlight.
- This Boiling Water Tank is only intended for use with compatible Bristan Boiling Water Taps. Using this tank with any other tap will invalidate the guarantee.
- Do not attempt to open or modify the Boiling Water Tank as this will invalidate the guarantee.
- The filter supplied must be replaced every six months for the protection of your Boiling Water Tank. Failure to do so will invalidate your guarantee.
- To protect against electric shock, do not place the cord, plugs, or Boiling Water Tank near or in water/ other liquids. Do not operate the appliance or touch the plug with wet hands.
- Only use the power lead supplied with the product. If the power lead is damaged, stop using it immediately and contact Customer Services for a replacement. Do not attempt to fix it as this can result in serious injury or death.
- Do not remove the earthing terminal, reconstruct the plug, or disassemble the main box or any part for the power.
- The appliance must be installed vertically with the inlet and outlet connections at the top of the unit. Ensure that the front of the unit is visible and the touch-screen can be easily reached.
- ~~~~Warning: This appliance is not intended for use by children or persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge; unless they have been given supervision or instruction concerning the use of the appliance in a safe way, and understand the hazards involved.
- Children should not play with the appliance. Cleaning and maintenance should not be undertaken by children without supervision.
Specification
Prior to Installation
All products manufactured and supplied by Bristan are safe to use provided
they are installed, operated correctly and receive regular maintenance in
accordance with these instructions.
This product has been designed to comply with the Water Supply (Water
Fittings) Regulations 1999 and current bylaws.
For full Installation Requirements & Notes (IRN) please visit
wras.co.uk/directory.
Remove all packaging and check the contents for damage before starting any
installation.
Fitting isolation valves (not supplied) to the inlet feeds is required as
close as is practical to the inlet connections for ease of maintenance.
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder etc.
Ensure an electric socket is near the place of installation; if a socket needs
to be installed, please request the services of a qualified electrician.
Pack Contents
Tools You’ll Need
Installation Requirements
Positioning the Boiling Water Tank Place the tank in a suitable, well-
ventilated location that will not fall below 0°C.
Ensure that the tank is installed vertically on a level surface with adequate
space around the tank. Keep away from direct sunlight.
We recommend installing a Drain Pan and waste (not supplied) to protect
against water damage and for ease of emptying the tank.
Also, ensure that the Filter is in an easily accessible place for replacement
purposes.
Ensure that the tap tails and filter connections can reach the connection
points.
Connection Diagram
Installation
Test Strip
Colour| Yellow| Dark
Yellow| Orange| Dark
Orange| Red| Dark Red| Very
Dark Red
---|---|---|---|---|---|---|---
Alkalinity
Measurement
(PPM)| 0| 50| 120| 180| 250| 425| 1000
Filter Setting| 6| 5| 4| 3| 2| 1| 0
Using the result of the water test carried out in Step 7, push and turn the
pre-fitted blue key to the required filter setting.
The key must then be removed from the filter head and kept for future
adjustment.
Prime the Filter/Tank
Place a jug under the spout and expel all air from the system.
Check connections for any leaks.
Runoff at least 20 liters of water from the Boiling Water Touch Control
handle, resting the system every 30 seconds.
Your Tap is now Ready for Use.
Operation
Operation
General Cleaning
Your fitting has a high-quality finish and should be treated with care to
preserve the visible surfaces. All surfaces will wear if not cleaned
correctly, the only safe way to clean your product is to wipe with a soft damp
cloth. Stains can be removed using washing-up liquid.
All bath cleaning powders and liquids will damage the surface of your fitting,
even the non-scratch cleaners.
Note: Never use abrasive detergents or disinfectants or those containing
alcohol, hydrochloric acid, or phosphoric acid.
Optimum Temperatures
Temperature | Suitable For |
---|---|
75°C | Green Tea |
85°C | Instant Coffee/ Oolong Tea |
90°C | Oolong Tea/ Brewing Coffee |
95°C | Brewing Coffee |
96°C
97°C| Black Tea/Herbal Tea
98°C
Operation – Boiling Water
Maintenance
Cleaning Outlet
Emptying the Boiling Water Tank
Changing the Filter
Maintenance Schedule
We have included this maintenance schedule in order to help keep track of when to replace your filter; which can be ordered using RAP SCALE FILT on the Bristan website. Please ensure your plumber fills in the date of installation.
Date Installed/Replaced | Date Installed/Replaced |
---|---|
/ /____ | |
Notes
Troubleshooting
Symptom | Cause | Remedy |
---|---|---|
‘99’ flashing in the ‘Set Temperature’ display. | The boiling Water Tank is |
empty at first
switch-on.
| Follow the Preparation for Use section.
The boiling Water Tank isn’t holding water.| Check connections for any
leaks/blockages. Contact Customer Services.
E3 Error Code in the ‘Set Temperature’ display.| No Water in Tank after first
use
E4 Error Code in the ‘Set Temperature’ display.| Thermistor Fault| Please
contact Customer Services.
Water/Steam is spitting from the spout.| Unit is boiling.| Turn the Instant
Hot Water Tap handle and release the water.
Adjust the water temperature to a lower setting – See Operation.
Check the aerator isn’t blocked.
Follow the Preparation for Use section to remove any airlocks.
The water is not hot.| The Boiling Water Tank is unplugged.| Make sure the
appliance is plugged in and the display is lit.
Make sure the circuit breaker and fuse are working correctly.
The Boiling Water Tank is not switched-on.| Follow the Start-Up steps (pg10)
and wait until the Status Arc is fully lit before use.
The water hasn’t finished heating up.
The water is too hot.| The water temperature is set too high.| Set the water
temperature to a lower setting – See Operation.
Water is dripping from the spout.| Residual water tension.| This is caused by
the build-up of water in the tap body and is normal for a short period of
time.
The Expansion Chamber isn’t draining correctly.| Draw off 500ml of water to
clear and prime the system. Avoid drawing off less than 150ml peruse.
Blocked spout.| See Maintenance Section to Clean Aerator.
Slow flow from the spout.| Water Filter needs changing.| Refer to the
Maintenance Steps to change the water filter. This must be changed every 6
months or it will invalidate the guarantee.
Water doesn’t flow straight away.| This appliance is designed for non-
pressurized operation. There will be a slight delay until the instant hot
water appears.| After a large volume of water has been drawn off, there may be
a slightly longer delay in water appearing from the Instant Hot Water spout.
No water flowing.| Closed/Partially closed isolation valves.| Make sure
isolation valves are fully open.
Flexible tails kinked/blocked.| Ensure pipes are not twisted or kinked to
restrict flow.
The boiling Water Tank may be blocked.| Contact Customer Services.
Troubleshooting Continued
Symptom | Cause | Remedy |
---|---|---|
Error Code 8 | The program needs resetting | Restart the tank |
Error Code 8 after restarting the tank | Error with the circuit board | Replace |
the tank
| |
Bristan Group Ltd.
Birch Coppice Business Park
Dordon
Tamworth
Staffordshire
B78 1SG
Web: www.bristan.com
Email: enquire@bristan.com
A Masco Company
At Bristan, we want to make things as easy as possible for our customers.
That’s why we offer solid guarantees on all our products, effective from the
date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your
product.
Alternatively, visit
www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where
our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-
centre/guarantees.
We Know & We Care