BRISTAN GLL RAPSNK3 SF C Gallery Rapid Boiling 3-in-1 ScaleFilter Sink Mixer Chrome User Guide

June 6, 2024
BRISTAN

Installation Instructions
and User Guide
Gallery Rapid Boiling 3-in-1
ScaleFilter Sink Mixer Chrome

Models Covered:
GLL RAPSNK3 SF C
Please keep this booklet for future reference.
The installer, when you have read these instructions please ensure you leave them with the user.

Thank you for choosing Bristan, the UK’s leading tap and shower expert.
We have designed this product to be easy to install and use. It has also been assessed to all of the relevant British Standards and conforms to UKCA and CE Regulations.
These instructions are for your guidance to a safe and successful.

Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

Important Safety Information

  • Please read these instructions thoroughly and retain them for future use.
  • All products manufactured and supplied by Bristan are safe provided they are installed, used correctly, and receive regular maintenance in accordance with these instructions.
  • If you are in any doubt about your ability to install this product safely you must employ the services of an experienced qualified plumber/electrician.
  • ~~~~Warning: The Boiling Water Tank is intended for domestic use only. Do not install the unit outdoors or where it might be subjected to damp or freezing conditions.
  • Check the power rating of the Boiling Water Tank is suitable for the power rating of the electrical circuit that it is being installed on
  • Check that no parts are missing or damaged on the Boiling Water Tank or Tap as per the instructions. If parts are missing or damaged, do not install and contact Customer Services
  • Ensure the Boiling Water Tank is installed in a room/environment with an access point. This is required to prevent condensation from forming within the unit. Keep away from direct sunlight.
  • This Boiling Water Tank is only intended for use with compatible Bristan Boiling Water Taps. Using this tank with any other tap will invalidate the guarantee.
  • Do not attempt to open or modify the Boiling Water Tank as this will invalidate the guarantee.
  • The filter supplied must be replaced every six months for the protection of your Boiling Water Tank. Failure to do so will invalidate your guarantee.
  • To protect against electric shock, do not place the cord, plugs, or Boiling Water Tank near or in water/ other liquids. Do not operate the appliance or touch the plug with wet hands.
  • Only use the power lead supplied with the product. If the power lead is damaged, stop using it immediately and contact Customer Services for a replacement. Do not attempt to fix it as this can result in serious injury or death.
  • Do not remove the earthing terminal, reconstruct the plug, or disassemble the main box or any part for the power.
  • The appliance must be installed vertically with the inlet and outlet connections at the top of the unit. Ensure that the front of the unit is visible and the touch-screen can be easily reached.
  • ~~~~Warning: This appliance is not intended for use by children or persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge; unless they have been given supervision or instruction concerning the use of the appliance in a safe way, and understand the hazards involved.
  • Children should not play with the appliance. Cleaning and maintenance should not be undertaken by children without supervision.

Specification

Prior to Installation

All products manufactured and supplied by Bristan are safe to use provided they are installed, operated correctly and receive regular maintenance in accordance with these instructions.
This product has been designed to comply with the Water Supply (Water Fittings) Regulations 1999 and current bylaws.
For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory.
Remove all packaging and check the contents for damage before starting any installation.
Fitting isolation valves (not supplied) to the inlet feeds is required as close as is practical to the inlet connections for ease of maintenance.
Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc.
Ensure an electric socket is near the place of installation; if a socket needs to be installed, please request the services of a qualified electrician.

Pack Contents

Tools You’ll Need

Installation Requirements

Positioning the Boiling Water Tank Place the tank in a suitable, well- ventilated location that will not fall below 0°C.
Ensure that the tank is installed vertically on a level surface with adequate space around the tank. Keep away from direct sunlight.
We recommend installing a Drain Pan and waste (not supplied) to protect against water damage and for ease of emptying the tank.

Also, ensure that the  Filter is in an easily accessible place for replacement purposes.
Ensure that the tap tails and filter connections can reach the connection points.

Connection Diagram

Installation

Test Strip
Colour| Yellow| Dark
Yellow| Orange| Dark
Orange| Red| Dark Red| Very
Dark Red
---|---|---|---|---|---|---|---
Alkalinity
Measurement
(PPM)| 0| 50| 120| 180| 250| 425| 1000
Filter Setting| 6| 5| 4| 3| 2| 1| 0

Using the result of the water test carried out in Step 7, push and turn the pre-fitted blue key to the required filter setting.
The key must then be removed from the filter head and kept for future adjustment.

Prime the Filter/Tank

Place a jug under the spout and expel all air from the system.
Check connections for any leaks.
Runoff at least 20 liters of water from the Boiling Water Touch Control handle, resting the system every 30 seconds.
Your Tap is now Ready for Use.

Operation

Operation

General Cleaning

Your fitting has a high-quality finish and should be treated with care to preserve the visible surfaces. All surfaces will wear if not cleaned correctly, the only safe way to clean your product is to wipe with a soft damp cloth. Stains can be removed using washing-up liquid.
All bath cleaning powders and liquids will damage the surface of your fitting, even the non-scratch cleaners.
Note: Never use abrasive detergents or disinfectants or those containing alcohol, hydrochloric acid, or phosphoric acid.

Optimum Temperatures

Temperature Suitable For
75°C Green Tea
85°C Instant Coffee/ Oolong Tea
90°C Oolong Tea/ Brewing Coffee
95°C Brewing Coffee

96°C
97°C| Black Tea/Herbal Tea
98°C

Operation – Boiling Water

Maintenance

Cleaning Outlet

Emptying the Boiling Water Tank

Changing the Filter

Maintenance Schedule

We have included this maintenance schedule in order to help keep track of when to replace your filter; which can be ordered using RAP SCALE FILT on the Bristan website. Please ensure your plumber fills in the date of installation.

Date Installed/Replaced Date Installed/Replaced
/ /____

Notes

Troubleshooting

Symptom Cause Remedy
‘99’ flashing in the  ‘Set Temperature’ display. The boiling Water Tank is

empty at first

switch-on.

| Follow the Preparation for Use section.
The boiling Water Tank isn’t holding water.| Check connections for any leaks/blockages. Contact Customer Services.
E3 Error Code in the ‘Set Temperature’ display.| No Water in Tank after first use
E4 Error Code in the ‘Set Temperature’ display.| Thermistor Fault| Please contact Customer Services.
Water/Steam is spitting from the spout.| Unit is boiling.| Turn the Instant Hot Water Tap handle and release the water.
Adjust the water temperature to a lower setting – See Operation.
Check the aerator isn’t blocked.
Follow the Preparation for Use section to remove any airlocks.
The water is not hot.| The Boiling Water Tank is unplugged.| Make sure the appliance is plugged in and the display is lit.
Make sure the circuit breaker and fuse are working correctly.
The Boiling Water Tank is not switched-on.| Follow the Start-Up steps (pg10) and wait until the Status Arc is fully lit before use.
The water hasn’t finished heating up.
The water is too hot.| The water temperature is set too high.| Set the water temperature to a lower setting – See Operation.
Water is dripping from the spout.| Residual water tension.| This is caused by the build-up of water in the tap body and is normal for a short period of time.
The Expansion Chamber isn’t draining correctly.| Draw off 500ml of water to clear and prime the system. Avoid drawing off less than 150ml peruse.
Blocked spout.| See Maintenance Section to Clean Aerator.
Slow flow from the spout.| Water Filter needs changing.| Refer to the Maintenance Steps to change the water filter. This must be changed every 6 months or it will invalidate the guarantee.
Water doesn’t flow straight away.| This appliance is designed for non- pressurized operation. There will be a slight delay until the instant hot water appears.| After a large volume of water has been drawn off, there may be a slightly longer delay in water appearing from the Instant Hot Water spout.
No water flowing.| Closed/Partially closed isolation valves.| Make sure isolation valves are fully open.
Flexible tails kinked/blocked.| Ensure pipes are not twisted or kinked to restrict flow.
The boiling Water Tank may be blocked.| Contact Customer Services.

Troubleshooting Continued

Symptom Cause Remedy
Error Code 8 The program needs resetting Restart the tank
Error Code 8 after restarting the tank Error with the circuit board Replace

the tank
| |

Bristan Group Ltd.
Birch Coppice Business Park
Dordon
Tamworth
Staffordshire
B78 1SG
Web: www.bristan.com
Email: enquire@bristan.com

A Masco Company
At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively, visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service- centre/guarantees.

http://www.bristan.com/service-centre/product- registration?channel=bristan&sid=fniFJaHIZjqhnFJ6J61h3xLfmrplEr

We Know & We Care

Read User Manual Online (PDF format)