microbeau FLUX S Spektra Wireless Cartridge Machine User Manual

June 6, 2024
microbeau

microbeau Logo

microbeau FLUX S Spektra Wireless Cartridge Machine

microbeau FLUX S Spektra Wireless Cartridge Machine

SAFETY NOTICE

CLASS III SYMBOL

A Class III appliance is designed to be supplied from a separated/safety extra-low voltage (SELV) power source. The voltage from a SELV supply is low enough that under normal conditions a person can safely come into contact with it, without risk of electrical shock. The extra safety features built into Class I and Class II appliances are therefore not required. For medical devices, compliance with Class III is not considered sufficient protection, and further more-stringent regulations apply to such equipment.

TECHNICAL DATA
Operating Voltage 5 – 12 V DC
Current 1A
Stitch Frequency 25 -160 Hz
Stroke 3 mm
Connection USB-C
Drive Brushless 9-Watt motor
Operating Mode Continuous Operation
Ambient Temperature +10 to +35°C
Relative Humidity 30 to 75%
Dimensions (Ø X L) 35 x 125 mm
Weight Approx. 170 g
BARRIER PROTECTING YOUR MACHINE

Although the grip is autoclavable, we strongly suggest the use of barrier products to protect your machine. For a visual demonstration of many barrier protection methods, please visit our YouTube
channel Microbeau.
“This machine is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge”.

MACHINE OVERVIEW

MACHINE OVERVIEW 01

MACHINE OVERVIEW 02

MACHINE OVERVIEW 03

THE SPEKTRA FLUX S

Unleash your Power
The first wireless pen-style machine featuring a detachable battery, complete Bluetooth connectivity, and a whole new level of freedom.

THE GRIP

Spektra Flux S Grip

THE GRIP

Autoclavable Ergonomic Grip DesignAutoclavable Ergonomic Grip
Design

Compatible with most membrane needle cartridges on the marketCompatible
with most membrane needle cartridges on the market

THE GRIP

The Flux S grip allows artists ratcheting control over needle depth. The standard Grip has a diameter of 28mm. Other grip options will be available soon. The Grip is crafted from a solid rod of 6061 T6 aircraft-grade aluminum. This polished and anodized grip is safe to be sterilized under steam, in an autoclave or sprayed with cold sanitation solutions.

THE BODY

Spektra Flux S Body
Spektra Flux S Body 01

Spektra Flux S Body 02

THE BODY

The Body is the core of the machine. Constructed from a solid rod of 6061 T6 aircraft- grade aluminum, this module should be sanitized by wiping it with cold sterilization solutions only. Caution: Avoid getting fluids into the housing.

Body Isometric View
Body Isometric View

Body Posterior View
Body Posterior View

THE POWERBOLT

Flux S PowerBolt
Flux S PowerBolt

THE POWERBOLT
LED indicator:
Solid Color = Whole Value
Blinking Color = Half Increment
Ex. Solid green indicates 10V
Flashing green indicates 10.5V

Battery Level Check: Press and hold power button till white. A blinking colored light indicates remaining charge.

LED Indicator

Note: LED flashes while battery charges. Once < 15% is reached, red light will blink alternately with voltage.

Working with modes: Modes work by pressing and releasing the power button.
Bluetooth – Hold the power button until a blue light appears and immediately release the power button. A blue blinking light indicates pairing mode is available for 60 seconds. To deactivate Bluetooth, hold the power button and release when the yellow light flashes.
Travel Mode (Shutdown) – Press and hold the power button until the red light flashes. This mode is for when you want to avoid unnecessary discharge and / or comply with travel laws. To reactivate, connect / disconnect to a USB-C port.

PowerBolt Top Bottom Views

Reset (Factory Settings) – Should you experience abnormal behavior, hold the power button and the voltage down button at the same time, then quickly release.
Device Reset: POWER + DOWN Button

DETACHING THE POWERBOLT

DETACHING THE POWERBOLT

DETACHING THE POWERBOLT

To detach your PowerBolt, ensure you have a firm grip on the Body and Grip. Turn the PowerBolt counter clockwise and pull out. To attach the PowerBolt, push in while twisting clockwise. Ensure lock mechanism moves freely. PowerBolt must sit correctly to ensure power leads align correctly. Avoid contact with the PowerBolt leads while recharging or servicing.

USB-C CONNECTION

USB-C CONNECTION

This connecting terminal is compatible with most USB-C cables on the market. We recommend you use the included cable for recharging the PowerBolt.

USB-C Darklab Supplied Cord

CONNECTING YOUR MACHINE

  1. Plug the USB-C cord into the PowerBolt connector.
    CONNECTING YOUR MACHINE 01

  2. Best connection.

  3. Improper connection.
    CONNECTING YOUR MACHINE 03

Insert the provided USB-C cable into the back of the PowerBolt and connect to a Hover or power socket. Make sure the cable is properly seated and is fully inserted into PowerBolt. The PowerBolt is not meant to operate while plugged in. The USB-C connection is meant only for recharging your PowerBolt. PowerBolt can be recharged whether or not it is connected to the Flux S. If connecting to a Hover, the charge speed will be up to 1.0 A.

ADJUSTING NEEDLE DEPTH

To adjust needle depth, hold the machine body and PowerBolt while turning the Grip. A counter clockwise turn decreases depth, while a clockwise turn increases depth (also known as needle hang). Each time you turn the grip you can feel the tactile feedback of the ratcheting mechanism. Each “click” displaces your needle 0.2mm and allows you to set your needle precisely without involuntarily turning while tattooing.

Increases Needle Depth Increases needle depth Turning the grip as shown increases needle depth.

Decreases Needle Depth
Turning the grip as shown decreases needle depth.

ADDITIONAL INFORMATION

VOLTAGE PARAMETERS

While voltage is a parameter that will vary from artist to artist, this machine has been tested to operate at a minimum voltage of 5 Volts and a maximum voltage of 12 Volts.
Depending on the type of needle configuration or brand you use, feel free to adjust the voltage to obtain the desired performance.

ACCEPTED NEEDLES

Use only cartridge needles with an internal membrane. This will avoid accidental contamination inside your machine. Fluids such as ink, water or oil will void warranty of the device and may require replacement of internal parts.

MAINTENANCE
  • Flux S is sold pre-lubricated from the factory and does not need internal lubrication.
  • Prevent any type of external elements from entering inside the machine as they will disrupt the motion of the component and contaminate lubrication.
  • The grip of the machine is autoclavable. Use only steam autoclaves at temperatures no higher than 270° Fahrenheit or 132.222° Celsius. Add a hint of ointment or PTFE grease around internal opening of grip or on stabilizing friction O-rings for optimal functionality after autoclaving. Refer to page 5 for additional information.
  • Machine Body and PowerBolt can be sanitized from the outside with cold sterilization products.
  • Never spray the surface directly to prevent fluids from entering the machine. Always use pads or disposable paper towels to apply sterilization products.
  • DO NOT DISASSEMBLE MACHINE.
WARRANTY
  • All the housing components (Grip, Machine Body and PowerBolt) are covered by a lifetime warranty.
  • Internal parts are subject to wear and the motor itself will be covered by a 1 year warranty from the date of purchase.
  • Motor warranty is void if motor shows signs of being dropped, of internal fluids entering the motor, and/or IF motor shows signs of being tampered with in any way.
HANDY TIPS

The following tips will help you get the most out of your Spektra Flux S and avoid potential issues:

  • Always secure your machine. Dropping the machine can cause damage to the magnets, bearings and brushes of the motor.
  • Use only cartridges with membranes to avoid contamination.
  • Rinse your needle frequently to avoid pigment drying up and slowing down your cartridges. When rinsing your needle, ensure to dip only the tip of the cartridge to avoid back flow of fluids.
  • Inspect your needles prior to use.
  • Avoid scratching the surface of the embodiments.
  • Use only FDA-approved cold sterilization solutions for disinfection.
  • Do not lubricate machine unless instructed otherwise.
  • Store your machine in a secure place.
  • Before first use, charge battery for a minimum of 3 hours.

TROUBLESHOOTING

  1. Machine Manufacturer
    Microbeau Int.: 1771 NW 79th Avenue, Doral, Florida 33126

  2. Servicing Your Machine
    Just like any mechanical device subject to use, Microbeau strongly suggests that you service your product at least once a year to ensure that a proper diagnosis of all working parts is conducted. This ensures the optimal condition of all working parts including internal machine clean up and fresh lubrication. Routine servicing will ensure that your machine remains functioning like the very first day. Service is subject to fees.

  3. Warning
    Disconnect machine from any power before making any adjustments.

For service inquiries, please contact service@microbeau.com.
For additional tips and tutorials, please visit Microbeau’s YouTube channel.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals