OVERVIEW
1. LCD display | 5. [ CH1 ~ 4 ] slide switch |
---|---|
2. [ MODE ] key | 6. [ RESET ] key |
3. [ CHECK ] key | 7. Battery compartment |
4. Wall mounting holder | 8. DC adapter USB power port |
BATTERY INSERTION
- Unscrew and remove the battery door of sensor with a screwdriver.
- Insert the 3 rechargeable batteries (included) into the battery compartment in the following order:
- Screw the battery door compartment on
- After inserting batteries, all LCD segment will be shown for 1
Note:
- Please prepare a screwdriver for removing and close the battery
GETTING STARTED
- Slide [ CHANNEL ] to set the channel number for your sensor(s).
- Use a pin to press [ RESET ] key for run the channel
Note:
- If there are more than one sensor in use, ensure to assign different channels number for each sensor to enable the measurement to displayed correctly on the console (purchase of separately).
LCD DISPLAY
- 5 / PM10 display mode 4
- 5 / PM10 concentration value 1 5
- 5 / PM10 concentration level
- Sensor Wireless channel number 6
- Transmission signal 2
- Battery power indicator
DISPLAY MODE
Press [ MODE ] to toggle the display mode between PM10 and PM2.5.
MEASUREMENT INTERVAL
Powered by DC adapter
The device measures PM2.5 or PM10 concentration every minute automatically
when powered with a DC adapter.
Manual detection
User can press [ CHECK ] button anytime to get an updated measurement
of PM2.5 or PM10 concentration readings. (It takes approximate 10-12s to
detect, the readings indicated by blinking PM2.5/PM10 icon.)
Operated by batteries
When powered by batteries, it’s detecting every 10 minutes by default. To
maximize the battery life, user can also change the detection interval from 10
minutes to 20 or 30 minutes.
Setting default measurement interval
- Press and hold [ CHECK ] for 2 seconds until the display is flashing
- Press [ MODE ] to choose which interval
- The setting sequence: 10m 20m 30m
- Press [ CHECK ] to finish the setting and back to normal display.
Detection interval
( Minute )
| Description
---|---
1(when connected to adapter)| The sensor will detect the PM value every 1
minute
10 (default)| The sensor will detect the PM value every 10 minutes
20| The sensor will detect the PM value every 20 minutes
30| The sensor will detect the PM value every 30 minutes
PM2.5/PM10 CONCENTRATION
For easy visualization of air quality, the device spreads the concentration readings over 6 level scale.
The following provides some gives health guidelines on activities between good and hazardous air quality
PM2.5| PM10| Health persons| Elderly, Children, Pregnant women| Persons with
chronic disease or heart disease
---|---|---|---|---
0~35| 0~50| Continue with normal activities| Continue with normal activities|
Continue with normal activities
36~53| 51~75| Continue with normal activities| Continue with normal
activities| Continue with normal activities
54~70| 76~100| Reduce prolonged or strenuous outdoor physical exertion|
Minimize prolonged or strenuous outdoor physical exertion| Minimize prolonged
or strenuous outdoor physical exertion
71~150| 101~350| Avoid prolonged or strenuous outdoor physical exertion|
Minimize outdoor activity| Avoid outdoor activity
151~250| 351~420| Minimize outdoor activity| Avoid outdoor activity| Avoid
outdoor activity
251+| 420+| Avoid outdoor activity| Avoid outdoor activity| Avoid outdoor
activity
Always consult/check with your doctors for any medical advices concerning the air quality and your health.
Note:
This 6 level scale of PM2.5 / PM10 concentration is not the same as Air
Quality Index (AQI).
BATTERY POWER STATUS
The device is powered by rechargeable batteries, and comes with battery power indicator. The battery life of the device from fully charged batteries is determined by the number of detections it performed, either through set intervals or manually activated by user.
When battery power fails to below 20%, user should recharge the batteries by connecting to a USB port using the cable provided.
Note:
When the wireless PM2.5/PM10 air quality sensor’s battery power is below 20%,
its detection function will temporary suspension.
CHARGING BATTERY
You can use the micro USB cable to charge the wireless PM2.5/PM10 sensor if
the battery states show in “Low battery”. When Micro USB port plug in the
micro USB cable for charging, the LCD will display and flashing battery icon.
Note:
Charged to full capacity from <20% battery power status require 24 hours.
REPLACE THE RECHARGEABLE BATTERIES
Over time, the batteries may degrade in terms of holding the highest capacity for which it was designed for. If you find the device’s battery power is not lasting as it used to be, it’s probably a good time to change them.
-
Unscrew and remove the battery door of sensor with a screwdriver
-
Pull the black ribbon lying under the batteries. All batteries can be removed together.
-
Insert new 3 x AA size rechargeable batteries into the battery compartment according to the polarity mark inside battery compartment.
-
Screw the battery door compartment on tightly.
-
After inserting batteries, all LCD segment will be shown for 1 second.
Note:
Please prepare a screwdriver for removing and close the battery door.
PAIRING WIRELESS SENSORS TO CONSOLE DISPLAY
This Wireless PM2.5/PM10 Air Quality Sensor can connect to the Air Quality Display console.
- After power up the wireless air quality sensor, it will automatically enter registration mode for 10 minutes until which it can be paired by the display
- Once the connection is successful, the signal strength indication and PM2.5/ PM10 information will appear on the display console.
Note:
- If you need to re-assign the sensor channel, slide the channel slide switch to the new channel position, then use a pin to press [ RESET ] key to restart the
- To avoid the sensor(s) and console pairing failure during new channel number assigned and setup, please power up the sensor(s) first, and then press [SENSOR ] key on the main
- After connected to the console display, the reading will transmit every 12 seconds in the first 5 minutes. Every reading transmission, the symbol of signal transmission,will flash 0.5 seconds at once.
VIEW DATA ON CONSOLE
You can view the readings of your PM2.5/PM10 sensor(s) on the console
receiver to which the sensor(s) is linked to. Readings can then be analyzed
into averages of past 24 hours or maximums of past 1 hour, 24 hours, or since
its last reset.
DATA TRANSMISSION
The device transmits its updated reading at fixed interval of 60 seconds to
the paired console receiver.
RESET THE SENSOR
In case of malfunction, use a pin to press [ RESET ] button to reset
the sensor.
SENSOR INSTALLATION
The sensor is designed for desktop or wall mount for easy viewing. Follow
the guidelines below for the sensor placement.
- Choose an open area away from any emissions source of pollutants, heat source, or with air flow greater than 1m/s.
- Place the wireless PM2.5/PM10 sensor at least 1.5m to 2m above the ground to better illustrate the detection of air quality in the human breathing zone.
- Do not expose the sensor to direct sunlight.
Wall mounting
Place a screw on the wall where you wish to hang for sensor. Hang the sensor on to the screw with or without the mounting adaptor.
Note:
– Higher siting may also be appropriate if the sensor is representative of a
large area.
SPECIFICATIONS
WIRELESS PM2.5/PM10 AIR QUALITY SENSOR
Dimensions (W x H x D)| 82 x 120.5 x 41mm (3.2 x 4.7 x 1.6 in)
Main power
| 3 x AA size 1.2V NiMH rechargeable batteries USB charging (5V500mA)
1m/1.2m USB charging cable included
Operating temperature range| -10°C to 40°C ( -14°F to 140°F )
Operating humidity range| RH 1% to 90 %
PM2.5/pm10 Unit| ug/m³
RF frequency| 915MHz
RF transmission range| 100 meters (300 feet) line of sight
Number of channels| 4 (CH1~4)
Detection interval| 1 minute, 10 minutes (default), 20 minutes, 30 minutes
Transmission interval| 60 seconds
Mass concentration precision
| PM2.5:
±15 μg/m³ @ 0 to 100 μg/m³ (at 25°C)
±15% @ 100 to 1000 μg/m³ (at 25°C ±5°C )
PM10:
±30 μg/m³ @ 0 to 100 μg/m³ (at 25°C)
±30% @ 100 to 1000 μg/m³ (at 25°C ±5°C )
Mass concentration range| 1 to 1000 μg/m³
Mass concentration resolution| 1 μg/m³
Particle detection size range
| Mass concentration: PM2.5 and PM10 Number concentration: PM2.5 and PM10
Lower limit of detection| 0.3 μm
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving
- Increase the separation between the equipment and
- Connect the equipment into an outlet on a n a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for “ FCC RF Radiation Exposure Statement
Caution: To maintain compliance with the FCC’s RF exposure guidelines,
place the unit at least20cm from nearby persons.”
Thank you for purchasing the Wireless PM2.5/PM10 Air Quality Sensor. Please
read the instructions carefully according to the version you purchased and
keep the manual well for future reference.
IMPORTANT NOTE
-
Read and keep these instructions.
-
Do not cover the ventilation holes with any items such as newspapers, curtains etc
-
Do not clean the unit with abrasive or corrosive materials
-
Do not tamper with the unit’s internal This invalidates the warranty.
-
Only use fresh batteries. Do not mix new and old batteries.
-
Do not dispose old batteries as unsorted municipal Collection of such waste separately for special treatment is necessary.
-
Attention! Please dispose of used unit or batteries in an ecologically safe manner.
-
Technical specifications and user manual contents for this product are subject to change without notice.
-
CAUTION: Risk of explosion if the battery is replaced by an incorrect
-
High or low extreme temperatures that a battery cannot be subjected to during use, storage or transportation and low air pressure at high altitude.
-
Replacement of a battery with an incorrect type that can defeat a safeguard.
-
Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion or the leakage of flammable liquid or gas.
-
Leaving battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas
-
A battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas.
-
The sensor is intended for use only with the rechargeable Ni-MH batteries provided: Manufacturer: BPI
Model: BPI-50AA2000EHmAh (with marking 50AA2000mAh) -
This device is only suitable for mounting at height < 2m.