Ccl Electronics C3129A Wireless Lightning Sensor User Manual
- June 6, 2024
- CCL ELECTRONICS
Table of Contents
WIRELESS THERMO-HYGRO SENSOR
WIRELESS LIGHTNING SENSOR
Model: C3129A
User Manual
Thank you for selecting this wireless lightning sensor. This manual is used for the US version. Please read the instructions carefully according to the version you purchased and keep the manual well for future reference.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
” FCC RF Radiation Exposure Statement
Caution: To maintain compliance with the FCC’s RF exposure guidelines, place
the unit at least 20cm from nearby persons.”
IMPORTANT NOTE
– Read and keep these instructions.
– Do not cover the ventilation holes with any items such as newspapers,
curtains, etc.
– Do not clean the unit with abrasive or corrosive materials.
– Do not tamper with the unit’s internal components. This invalidates the
warranty.
– Only use fresh batteries. Do not mix new and old batteries.
– Do not dispose of old batteries as unsorted municipal waste. Collection of
such waste
separately for special treatment is necessary. – Attention! Please dispose of
used units or batteries in an ecologically safe manner. – Technical
specifications and user manual contents for this product are subject to change
without notice.
CAUTION
– Danger of explosion if the battery is incorrectly replaced. Replace only
with the same or equivalent type.
– Battery cannot be subjected to high or low extreme temperatures, low air
pressure at high altitude during use, storage, or transportation.
– Replacement of a battery with an incorrect type can result in an explosion
or the leakage of flammable liquid or gas.
– Disposal of a battery into fire or a hot oven, or mechanically crushing or
cutting of a battery, that can result in an explosion.
– Leaving a battery in an extremely high temperature surrounding environment
can result in an explosion or the leakage of flammable liquid or gas.
– A battery subjected to extremely low air pressure may result in an explosion
or the leakage of flammable liquid or gas.
– An appliance is only suitable for mounting at a height of 2m.
OVERVIEW
- Lightning indicator
- Noise indicator
- Transmission status LED
- Wall mounting holder
- [SENSITIVITY] slide switch to assign the sensor sensitivity to High / Mid / Low / Default
- [ RESET ] button
- Battery compartment
GETTING STARTED
- Remove the battery door.
- Slide the [ SENSITIVITY ] slide switch to choose a sensitivity mode.
- Insert 2 x AA-size batteries into the battery compartment according to the polarity mark on the battery compartment.
- Close the battery door.
- After inserting batteries, the transmission status LED will light up 1 sec.
NOTE:
– Once the sensitivity mode is assigned, you can only change it by removing
the batteries or resetting the unit.
– Avoid placing the sensor in direct sunlight, rain, or snow.
LED INDICATOR
Flashing mode | Description |
---|---|
One lightning strike was detected. | |
Noise signals were detected, reminding the user that the current location |
has high-level noise.
Please find another location with a lower noise level.
SENSITIVITY SLIDE SWITCH
– The sensor is intended to be installed outdoor under sheltered areas away
from noise generated by switches and household appliances that may trigger
false lightning.
– Default Setting (DF) is for sensitivity between high and mid-levels. If you
think the sensor picked up a lot of false lightning strikes, then please try
with sensitivity Mid (MI) or Low (LO). If the sensor missed lightning
detection, you may try with sensitivity High (HI).
PAIRING THE WIRELESS SENSORS WITH THE CONSOLE
The console will automatically search and connect to your lightning sensor.
Once your sensor pair up successfully, the sensor signal strength indication
and weather information will appear on your console display.
NOTE:
Every reading transmission, the transmission status LED will flash at once.
RESET THE SENSOR
In case of malfunction, press the [ RESET ] button to reset the sensor.
HOW TO PLACE THE SENSOR
– Choose a location on the exterior of the home where can shield the sensor
from direct sunlight or wet conditions for an accurate reading.
– Minimize obstructions such as doors, walls, furniture, etc.
– Hang it with the wall mount hole or place it directly on a flat surface, and
make sure the transmission is within 150 meters approx.
SPECIFICATIONS
Dimensions (W x H x D) | 125 x 58 x 19 mm (4.9 x 2.2 x 0.7 in) |
---|---|
Weight | 144g (with batteries) |
Main power | 2 x AA size 1.5V batteries (Lithium battery recommended for the |
low-temperature environment)
Weather data| Lightning strike and distance
RF frequency| 915Mhz (US)
RF transmission range| 150m (300feet) straight distance
Lightning detection range| 0 — 25 miles / 0 — 40 km
Transmission interval| 60 seconds
Operating temperature range| -20 — 60°C (-20 — 140°F)
Operating humidity range| RH 1% to 99 °A)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>