MONTIGO RX 100 Proflame 2 Upgrade Kit NG/LP Installation Guide
- June 6, 2024
- Montigo
Table of Contents
MONTIGO RX 100 Proflame 2 Upgrade Kit NG/LP
- The installation of this kit must be done by a qualified and certified gas appliance installer.
- Check local codes and read all instructions prior to installation.
CAUTION
Ensure that all power to the appliance is off at the electrical breaker or fuse before beginning installation. Ensure gas is turned off at the shutoff valve before beginning installation.
WARNING
When installing the fireplace – gas lines, fittings, accessories or any other objects cannot impede the proper movement of the door buckles.
WARNING
Some materials used in the manufacturing process of this product can expose
you to Benzene which is known in the State of California to cause cancer and
birth defects or other reproductive harm. For more information go to
www.P65warnings.ca.gov
Warning: If the information in these instructions is not followed
exactly, a fire or explosion may result causing property damage, personal
injury or loss of life.
◆ Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
◆ What To Do If You Smell Gas:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
◆ Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
General Information
This blower kit is for installation with the models listed above.
KIT # | Contents |
---|---|
RX100NG | Remote Control, Stepper Motor-NG, Manual Override switch with harness |
and bracket, backup battery pack, Proflame 2 operations manual, hardware and
batteries
RX100LP| Remote Control, Stepper Motor-LP, Manual Override switch with harness
and bracket, backup battery pack, Proflame 2 operations manual, hardware and
batteries.
Before You Begin
Ensure that the power supply has been turned off at the breaker or fuse before
beginning the installation.
Shut off the gas supply at the shut-off valve, and ensure that the main burner
and pilot light have been turned off and the fireplace has been cooled off for
at least two hours before installation.
Note: You may remove the front cover (See Figure 2), or the burner assembly to
access the control module and wiring. If removed, please ensure it is re-
installed properly and all gas connections are leak tested.
General Information
This upgrade kit contains the necessary components for field upgrade of an
approved Montigo fireplace from Proflame 2 standard control system to Full
Load with remote.
The installation of this unit must also conform with local codes or, in the
absence of local codes, with the American National Fuel Gas Code, ANSI Z223.1,
or the Canadian Installation Code, CAN / CGA B149.
WARNING!
This upgrade kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions are not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with this kit
Note
Upon successful installation of this upgrade kit, the following features are available for the user:
- Thermostatic and smart thermostatic control of the fireplace
- Main burner flame modulation (6 levels)
- Choice of Standing or Intermittent pilot (CPI switch or jumper required)
- Comfort fan speed modulation (Remote Fan Kit RFK50-R required)
- Battery backup for the main burner during power outage
Tool Required
T20 Torx bit
Impact gun / Drill
1/4 ” Nut driver bit
Installation
A. Disconnecting Wall Switch Harness:
- Remove valve blind and glass door.
- Disconnect the wall switch harness from X4 Control Module and discard.
B. Stepper Motor Installation:
-
Using a Torx T20 or slotted screw driver, remove the two screws that are attached to the Hi-Low knob on the Gas Control Valve (Figure 4) and discard the screws and the knob (Figure 5). Remove gasket and discard.
-
Ensure the prefitted rubber gasket is properly positioned (Figure 8 – D). Otherwise, fit the gasket as shown
-
Position the stepper motor on the gas control valve as shown in Figure 9 – E
-
Manually thread the two supplied mounting screws into the valve body. Use a torque screw driver with Torx T20 bit, to tighten the two screws to a torque setting of of 25 lb-in +/- 5%
-
Install the enclosed identification label to the valve body Figure 9 – G.
C. Main ON/OFF Switch Installation:
-
Position the Main ON/OFF Switch bracket on the right leg of the firebox as shown in Figure 12 and Figure 13.
-
Use the two supplied selftapping screws to attach the bracket. See Figure 13.
-
Feed the switch and the wires through the slot in the bracket as shown and install the switch to the bracket. See Figure 15.
-
Secure the wires to the floor of the fireplace using the supplied cable tie and cable tie mounts.
-
Attach the “Main ON/OFF” label supplied to the valve bracket.
D. Battery Holder Installation:
-
Secure the battery holder to the fireplace floor using the supplied velcro strips. See Figure 16.
Note: The velcro strips act as an electrical isolation, do not attach the battery holder to any metal part without using the velcro strips, or the control module will be damaged. -
Connect the red and black wires from the battery holder to the red and black wires from the valve harness. See Figure 17
E. Stepper Motor and ON/OFF Switch:
-
Connect the Manual ON/OFF switch to X4 of the control module.
-
Connect the stepper motor harness to X6
F. Operation with Backup Battery:
-
Install the four supplied AA batteries to the battery holder.
CAUTION: Please note battery orientation while installing them. Incorrect orientation may damage battery, cause fire hazard and the fireplace may not function properly. -
Follow the instructions on the “Proflame2 Operation and Maintenance Manual- XG0677” to install batteries on the remote control.
-
Turn the gas supply ON.
-
Program the remote control to the control module (see “Proflame2 Operation and Maintenance Manual- XG0677”).
-
Check the stepper motor for gas leaks and ensure no leak.
-
Turn the fireplace ON and modulate the flame using the remote control and ensure proper operation (see “Proflame 2 Operation and Maintenance Manual XG0677”).
G. Operation with MAIN Power:
- Remove the four batteries from the battery holder
- Plug the Control Module Power cord to the PPO box. See Figure 3.
- Turn the fireplace ON using the remote control and confirm operation with main power ON.
Note: You may re-install the backup batteries to the battery holder at this point to ensure that fireplace is operational during power outage. It is recommended to check and replace the backup batteries at least once a year. More frequent battery replacement may be required in case of extended operation on backup batteries.
CPI [Continuous Pilot Ignition] / IPI [Intermittent Pilot Ignition] Jumper Cable Installation (only available for SIT Electronic Ignition Systems)
“Why use CPI mode”?
CPI means “Continuous Pilot Ignition” or “Standing Pilot” as it is commonly
known. IPI means “Intermittent Pilot Ignition”, which only initializes the
pilot when you are going to be using the appliance.
There are several reasons why you may choose to use CPI mode. When a flue is cold it can be difficult to light the appliance. It can take a bit of time (particularly on tall vents) to initialize vent action. This can result in “lifting” or “ghosting” of the flames during the first two to three minutes of operation. It is also possible to encounter times when the fireplace fails to light successfully. The fireplace will then attempt to re-light a second or third time depending on prevailing temperatures or altitude. When in CPI mode the pilot also keeps the system warm. During a “cold” start, condensation will normally form on the inner glass surface of the door. This condensation will quickly dry, however, the condensation tends to run down the glass and cause some streaking. CPI mode helps to resolve this issue. If CPI mode is used during the winter months the energy it takes to run the pilot is partially recovered as heat into the building, so it does not waste as much energy as running a pilot in the off season.
If you use a wall switch:
A connector is supplied with this unit that can be plugged into the wire
harness connected to the controller. When the CPI jumper is connected, the
pilot will light and remain lit continuously. Use the wall switch to turn the
main burner on or off. To switch back to IPI mode you must unplug the CPI
jumper.
If you use the remote:
A connector is supplied with this unit that can be plugged into the wire
harness connected to the controller. This Jumper Cable gives the Remote
Control the ability to operate the CPI / IPI switch and set the unit to
operate in either condition.
The difference between IPI and CPI:
IPI (Intermittent Pilot Ignition) Mode: is a fuel saving mode in which
the pilot is only used when the main burner is on.
CPI (Continuous Pilot Ignition) Mode: The Pilot runs continuously even
when the main burner is off.
Installing the CPI Jumper Cable
-
Access the controller (refer to the installation and maintenance manual for your model).
-
Remove the bag containing the Jumper Cable from the wiring harness connected to the controller as shown in Figure 19.
-
Find the corresponding plug attached to the control wire harness and connect the CPI jumper.
-
See remote operation manual to turn remote into CPI mode.