Shenzhen Medica Technology Development M8701W Sleep Tracker User Manual
- June 6, 2024
- Shenzhen Medica Technology Development
Table of Contents
Shenzhen Medica Technology Development M8701W Sleep Tracker User Manual
Product Introduction
Please read this manual carefully before using the product and keep it properly. The product has the functions of real-time sleep monitoring, sleep data recording, sleep report, abnormal reminder, etc. The product is composed of a main monitoring pad and an extended monitoring pad. It can be divided into a single bed version (with main monitoring pad only), or a single bed extended version/double bed version (with extended monitoring pad). Users can choose according to different usage scenarios.
Main Monitoring Pad
**Extended Monitoring pad
**
Installation Instruction
Step 1: Acquire the bed width from the bed manufacturer or the actual
measurement of the bed width, then refer to the installation location
requirements and select the appropriate location for installation (see Figure
1-3 for the installation location of each version), please note that the
monitoring pad needs to be fixed at 50 – 60cm away from the bed head position,
with the LOGO facing up.
Single Bed Version Installation(Figure 1)
Single Bed Extended Version Installation (Figure 2)
Double Bed Version Installation (Figure 3)
Step 2 : Fix the monitoring pad. (Choose the following fixing method
according to the actual situation of the bed board). Method 1: Use adhesive to
fix. On the back of the monitoring pad, a 3M adhesive is attached to each
positioning frame (see Figure 4). Attach the device horizontally to the bed
board, the device’ s adhesive position should be pressed to ensure the device
is firmly attached to the bed board. Method 2: Use screws to fix and lock the
holes on the left and right sides of the monitoring pad, so that the device is
stably fixed on the bed board.
Main Monitoring Pad
Extended monitoring pad (Figure 4)
Step 3 : Connect the USB power cable (single bed extended version and
double bed version need to connect the extended monitoring pad’ s signal
cable), then connect the power supply and other devices to start the network
connection configuration. Step 4: Cover with mattress to complete the
installation (see Figure 5).
Precautions for installation and use
- This product is suitable for foam mattresses, spring mattresses, latex mattresses with the thickness of 6-30 cm. The use of water beds, air mattresses, and high-hardness mattresses may cause lower monitoring accuracy or function failure.
- The single bed version and the single bed extended version are only suitable for single person usage, and the double bed version is only suitable for double person usage. Please choose according to the actual situation.
- The product needs to be fixed on the hard bed frame (bed board) flatly and stably. There can be properly soft materials (such as soft cloth) between the equipment and the hard bed board. The soft material’ s thickness is recommended to not exceed 3mm.
- Please ensure that no vibration source is close to the sensor belt, so that the sensor belt can accurately monitor the user’s sleep. Vibration caused by electric fans, washing machines, loud music, etc. may cause misjudgment of this product.
App Search
“SleepNote” in the App Store or Google Play to download and install the SleepNote App. Supported mobile phone system versions: Android 4.4 and above, iOS 9.0 and above. Add and use the devices as the App prompts.
Indicator Light
Power On
| Green light is on
---|---
Power Off
| Red light is on and turns off in 3 seconds.
Network Disconnected|
Red light is blinking
Firmware Upgrading|
Green light is blinking
Specifications
Power Supply
Power Input| DC 5V lA
Rated Power|
5W
Bluetooth
Specification
|
V4.2 BR/EDR+BLE
Frequency Range|
2.4 GHz – 2.5 GHz
Wi-Fi
Specification
| 802.11 b/g/n
Frequency Range|
2.4 GHz – 2.5 GHz
Working Environment
Operating Temperature
| 0°C-40°C
Storage Temperature
|
-10°C-50°C
Humidity|
5%90% RH
Precautions
Please note, this device is not a medical device and cannot be used to prevent sudden death. This product is not suitable for people who wear pacemakers, please notice! This product is also not suitable for sleep monitoring of toddlers, children, developing teenagers
Safety Notice
- Please keep the product away from high-temperature equipment, and do not use the product when using an electrical blanket.
- Do not touch the metal end of power plug when plugging into power socket.
- Please power the device off if for a long term non-using.
- Do not let the device come in contact with liquids. It is not waterproof.
Warranty
Please contact your dealers for warranty service. For more information about the product, warranty or service, please go to www.sleepace.com
Disclaimer
To protect your legal rights, please read the instructions, disclaimers, important notices and safety items provided with this product before using this product to understand your legal rights, responsibilities and safety precautions. Otherwise, it may bring you property damage, personal safety hazards or accidents. Shenzhen Med ica Technology Development Co., Ltd. (Medica) reserves the right to update this document. Please be sure to operate this product in accordance with the instructions and safety instructions. Once using this product, you are deemed to have understood, approved and accepted all terms and conditions of the product’s instructions, disclaimers, important notices and safety matters, and have undertaken to be responsible for your actions and allconse-quences arising therefrom.
The user must also undertake to use the product solely for legitimate purposes and agree to abide by these terms and any other relevant policies or guidelines that may be specified by Medica. You understand and agree that if you do not use this product in accordance with the requirements of this product manual, Medica will not be able to provide you with after-sales service.
When using this product, please strictly observe and implement the requirements including but not limited to the instructions, disclaimers, important notices and safety matters. Any personal injury, accident, property or other loss and related legal disputes caused by any violation of this product manual and safety instructions or due to force majeure, and all other adverse events that may cause conflicts of interest shall be borne by the user. Medica will not be responsible for any related liabilities and losses. Due to the user’s failure to follow or strictly follow the instructions in this product manual, all losses caused by the use of this product shall be borne by the user. Medica shall not be liable for any losses.
In compliance with laws and regulations, Medica has the final rights to interpret this document and this product manual. Medica reserves the rights to update, modify or terminate this document without prior notice.
The contents of this manual are protected by copyright laws and regulations. It is strictly forbidden to copy, transmit, distribute and use any of the contents of this manual in any form without the written permission of the company. This disclaimer statement became effective on November 1, 2019.
FCC Warnning
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.