Important Safety Instructions: Read Before Installation

This luminaire is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty.

These instructions do not intend to cover all variations in installation, operation maintenance or mounting situations.

  1. Make sure that the power is turned OFF before installing or servicing this luminaire.
  2. Warning: risk of electrical shock. Install all luminaires 10 feet (3.05M) or more from pool, spa or fountain.
  3. This luminaire is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
  4. DO NOT INSTALL in walls where the capstones overhang the wall less than 3/4” [19mm] or under stairs where the tread overhangs the riser less than 3/4” (19mm).
  5. Wiring connections must be made with UL listed wire connectors that is suitable for outdoor use.
  6. Position the low voltage wire and UL listed wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminare, or fitting.
  7. The main low voltage cable is intended for shallow burial – less than 6 inches (152 mm).

Package Contents

A. (1) Luminaire
B. (2) Stainless Steel Screws

Product Dimensions

FIG 1 Product Dimensions

Optional: Install Glare Guard Before Installation

FIG 2 Product Dimensions

If you choose, you can attach the glare guard first before mounting the fixture.

Use the screws and washers to secure the glare guard onto the fixture. Tighten with a screwdriver.

Install Luminaire in Brick or Masonry Wall

1. Install Mounting Plate

FIG 3 Install Mounting Plate

Determine the desired location for each luminaire before construction of the wall is started.

Insert the stainless steel mounting plate (sold separately), in between the layers of hardscape material. If preferred, use an adhesive or mortar (sold separately), to secure the luminaire in place.

2. Install Luminaire

FIG 4 Install Luminaire

Route the luminaire wire through the wall to the main low voltage supply cable using standard masonry procedures. A “V” shaped notch can be cut into the hardscape material to aide in wire management.

Attach the glare guard and the luminaire to the stainless steel mounting plate by using mounting screws (ships with mounting plate).

3. Wire Connection

FIG 5 Wire Connection

Strip both leads from the luminaire pigtail. Using two UL listed wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads.

  • We recommend ace heat shrink style connectors for hardscape connections.

4. Adjust Lamp Direction

FIG 6 Adjust Lamp Direction

Using an Allen wrench, loosen the set screws on the ends of the lamp and then rotate the lamp to the desired direction. Always tighten the set screws after adjustments.

Install Luminaire in Railing, Deck Over-hang or Stair

1. Determine Luminaire Location

FIG 7 Determine Luminaire Location

Determine the desired location for the luminaire.
Place the luminaire to the mounting surface and mark two points on the mounting surface where the holes are on the ends of the luminaire. The marks will be used for self-tapping screws or wall anchors.

Note: Wall anchors are required for certain installation conditions (brick wall, concrete wall, etc.)

A wireway hole may be drilled through the decking fascia or other surface adjacent to the mounting surface.

  • Hold the luminaire in the desired mounting location. Mark the location where the wire exits the luminaire.
  • Drill a hole through surface (suggested 1/4” [6.5mm] hole).
  • Thread the wire through the drilled hole.

2. Install Luminaire

FIG 8 Install Luminaire

Install the luminaire and glare guard using provided self-tapping screws. If the screws are difficult to install, mark holes and drill 1/8” pilot holes.

If wall anchors are required, drill proper holes from the marks on the mounting surface and then insert the wall anchors. Then install the luminaire and glare guard and secure them with the selftapping screws.

Rubber washers are required during installation from the side.

NOTE: DO NOT OVER TIGHTEN SCREWS.

3. Wire Connections

FIG 9 Wire Connections

Strip both leads from the luminaire pigtail. Using two UL listed wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads.

  • We recommend ace heat shrink style connectors for hardscape connections.

4. Adjust Lamp Direction

FIG 10 Adjust Lamp Direction

Using an Allen wrench, loosen the set screws on the ends of the lamp and then rotate the lamp to the desired direction. Always tighten the set screws after adjustments.

Install Luminaire to Y Bracket

1. Determine Luminaire Location

FIG 11 Determine Luminaire Location

2. Install Riser

FIG 12 Install Riser

Pass the supply wire from the luminaire through the center hole on the Y bracket and the riser. Then thread the riser onto the Y bracket and hand tighten until snug.

3. Install Stake

FIG 13 Install Stake

Determine the desired location for mounting the stake. Hammer the stake into the ground until flange of stake is flush to grade. To avoid damage to the stake, place a board on top of the stake while hammering.

Note: If the ground is hard and the stake is difficult to install, make a crosscut in the ground using a flat shovel.

4. Intsall Riser to Stake

FIG 14 Intsall Riser to Stake

Clear away area in the ground at wireway slot on the top of the stake. Pass the fixture supply wire through the center hole of the stake and lay it into the wireway slots. Thread the riser onto the stake. Hand tighten until snug.

5. Wire Connections

FIG 15 Wire Connections

Strip both leads from the luminaire pigtail. Using two UL listed wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads.

  • We recommend ace heat shrink style connectors for hardscape connections.

6. Adjust Lamp Direction

FIG 16 Adjust Lamp Direction

Using an Allen wrench, loosen the set screws on the ends of the lamp and then rotate the lamp to the desired direction. Always tighten the set screws after adjustments.

www.voltlighting.com

Specifications and product details subject to change without notice.
© Copyright 2021, VOLT® Lighting, Lutz FL USA 33549 • All rights reserved. customersupport@voltlighting.com • 813.978.3700

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals