AIR INNOVATIONS HUMID61 Clean Mist Top Fill Ultrasonic Humidifier Instruction Manual
- June 6, 2024
- AIR INNOVATIONS
Table of Contents
C LEAN MIST® TOP-FILL
ULTRASONIC HUMIDIFIER
Instruction Manual and Warranty Information
READ AND SAVE THESE INSTRUCTIONS
If you have a respiratory condition, please contact your physician prior to use.
FCC STATEMENT
Potential for Radio/Television interference
This device complies with Part 18 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation. This product has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 18 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If the product does cause harmful interference to radio or television reception, which can be determined by turning the product on or off, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the product and the receiver.
- Connect the product into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS: Failure to follow all the instructions may result in electrical shock.
WARNING
- This appliance has a polarized plug (one blade is wider than the other) as a safety feature. If the plug does not fit fully into the outlet, reverse the plug. If it still doesn’t fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
- Before using the humidifier, extend the cord and inspect for any signs of damage; DO NOT use if the cord has been damaged.
- Keep cord away from heated surfaces and out of the way, where it cannot be stepped on or tripped over.
- NEVER use in an environment where explosive gases are present.
- Place humidifier on a stable level surface; DO NOT place on carpet, next to heating vents, under direct sunlight, in high-temperature areas, or near computers and electronic equipment.
- DO NOT place the humidifier directly on wood furniture or other surfaces which could get damaged by water.
- DO NOT direct the mist against a wall or home appliances.
- NEVER operate without water in the Tank; DO NOT use anything other than room temperature tap or distilled water.
- DO NOT touch the water in the Base during operation.
- DO NOT expose or immerse the Base in water when cleaning.
- DO NOT pour water into the base through the Air Outlet during cleaning and filling.
- NEVER block the Air Outlet or intake or cover the unit when it’s in operation
- DO NOT use any attachments not provided with the unit.
- Discontinue use if the humidifier makes loud noises or has a strange smell.
- DO NOT attempt to repair or adjust the unit; servicing must be performed by professional or qualified personnel.
CAUTION
- Only operate when fully assembled; only use as intended and described in this manual.
- Keep out of reach of small children.
- Always insert plug securely into the power source.
- Unplug the unit and empty the Water Tank and Base before carrying/moving.
- Only unplug when the humidifier is turned off; ensure hands are dry.
- Always turn off the unit before removing, emptying or filling the Water Tank.
- Perform regular maintenance of the Ultrasonic Nebulizer; NEVER scrape Nebulizer with a hard or sharp object.
- Dry the unit completely before storage; store in a cool, dry place.
- Do not drop, hit, or otherwise subject this product to excessive shock.
No More Dry Air
Thank you for choosing the Air Innovations® – Clean Mist® Top-Fill Ultrasonic
Humidifier and congratulations on taking this important step in improving the
quality of air in your home or office.
This Humidifier uses Ultrasonic Technology to create humidity instantaneously
while working silently to erase the discomforts of dry air.
Unpacking
Remove the humidifier from the box.
Remove all external and internal packing (refer to page 4.).
*Follow directions to fill and operate the humidifier.
Specifications
Parts & Contents
- Water Tank
- LED Light
- Water Reservoir / Base
- Power/Mist Control Knob
- Mesh Filter
- Water Window
- Air Inlet
- Ultrasonic Nebulizer
- Water Tank Cover
- Mist Outlet
- Water Sensor Float
- Water Sensor
**Filling The Water Tank
**
WARNING: If you have hard tap water, we recommend using ONLY filtered or
distilled water.
For first use:
-
Remove the Water Tank from the Base.
-
Remove the foam insert located above the Water Sensor Float.
-
Replace the Tank with the Mist Outletfacing forward.
-
Fill the Tank with clean, cool water. Do not allow water to enter the Mist Outlet.
About White Dust
The use of high mineral content water may cause a white mineral residue to
accumulate on surfaces in the room near the humidifier. The mineral residue is
commonly called “white dust” and is caused by minerals suspended in the water.
The higher the mineral content (or, the harder your water is), the greater the
potential for white dust. The dust is not caused by a defect in the
humidifier. To reduce white dust we recommend using filtered or distilled
water.
Operating Instructions
ON / OFF
Plug into a standard (120V AC) electrical outlet. Turn the Mist Control Knob
clockwise to turn the unit ON. The LED Light will illuminate blue. To turn
OFF, turn the Mist Control Knob counterclockwise until you hear a click and
the light turns off.
MIST OUTPUT
The unit will turn ON with the lowest mist setting. Turn the Mist Control Knob
clockwise to increase the mist output and turn the Mist Control Knob
counterclockwise to decrease. LOW WATER
When the tank is out of the water the LED Light will turn from blue to red and
the automatic safety shut-off will turn the Ultrasonic Nebulizer OFF. You may
hear the fan for a few seconds, this is normal.
Weekly Cleaning & Care
We recommend thoroughly cleaning the humidifier at least once a week.
To Clean the Tank
Remove the Water Tank and empty the water. Clean and wipe the Tank with a soft
damp cloth. If necessary a mild cleaning solution may be used. The Mesh Filter
Screws onto the base of the Tank. To clean, remove the filter, rinse with
water and replace.
To Clean the Base
Empty the water from the Base, pouring away from the Air Inlet. Wipe with a
soft cloth. To remove any scale or build-up in the Base or on the Ultrasonic
Nebulizer, pour a 50/50 mixture of vinegar and lukewarm water onto the
surface, then soak for five minutes. Clean with the provided brush and rinse.
Note: Never submerge the base in water or any liquid.
To Clean the Surface
Clean the surface of the humidifier with a clean, soft, damp cloth as often as
needed.
Storage
- Follow all cleaning instructions prior to storage.
- Dry all parts, including the inside of the Water Tank and the Water Reservoir.
- Preferably store in its original box, in a dry place away from high temperatures.
Troubleshooting
Problem | Solution |
---|---|
Weak or no mist output. | The water in the unit is too cold: Replace with cool |
but not cold water or set the output to High and wait 10-15 minutes.
The surface of the Ultrasonic Nebulizer is dirty: Clean Ultrasonic Nebulizer.
(see pg. 6)
Ultrasonic Nebulizer is not working: See Warranty.
White dust is forming on nearby furniture.| Hard tap water may deposit a
certain amount of dust.
To reduce white dust, we recommend filtered or distilled water.
Water is leaking.| A humidifier is not on a level surface: Place on a level
surface.
Condensation is forming around humidifiers or windows.| The mist output level
is too high for room size: Decrease the mist output.
Missing parts.| Call us toll-free at
844-600-1370, Monday thru Friday 8:30
am to 5 pm EST.
Please reference model: MH-419
Other Great Products
Warranty
1-YEAR WARRANTY – MH-419
Air Innovations® Clean Mist® Top-Fill Ultrasonic Humidifier comes with a 1-year manufacturer’s warranty. If this unit should become defective within 1-year from the date of purchase, or if you have any questions or comments regarding replacements for any of our products, please contact us directly at:
Call us toll-free at: 844-600-1370
Monday thru Friday 8:30 AM to 5:00 PM EST.
Visit us on the web at: www.Air-Innovations.com
e-mail us: sales@air-innovations.com
Or write us:
Great Innovations, LLC
Att: Quality Assurance Dept.
2301 SW 145th Ave.
Miramar, FL. 33027 USA
Please fill out the warranty card and
mail it back to the above address.
Or, register your warranty online today.
Simply go to:
www.Air-Innovations.com
NAME:
ADDRESS:
CITY:
STATE:
ZIP:
TELEPHONE:
E-MAIL:
DATE OF PURCHASE:
PLACE OF PURCHASE:
Please check here if you would not like to receive any solicitations from our company:
THIS UNIT COMES WITH A 1-YEAR WARRANTY SUBJECT TO THE FOLLOWING
CONDITIONS:
In the first year, all repairs will be performed free of charge or the unit
will be replaced. This warranty is not transferable, it is valid only for the
original purchaser. This warranty will be voided if the unit is subjected to
unauthorized repair or impact damage. If you have any questions please call
toll-free: 844-600-1370. This warranty
gives you specific legal rights, and you may also have other rights which vary
from state to state.
References
- innovations.com | Venture
- Air Innovations
- Lost Redirection
- Stylish Bags & Organizers For Your Lifestyle - Pursfection
- Best Cleaning Products | Shop Household Cleaning Products Now
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>