Miele PDR 908 HP Heat-Pump Dryer Installation Guide
- June 6, 2024
- Miele
Table of Contents
- Machine dimensions – measurements in inches-
- Installation -measurements in inches-
- Washer-dryer stack -measurements in inches-
- Machine dimensions – measurements in millimeters-
- Installation -measurements in millimeters-
- Washer-dryer stack -measurements in millimeters-
- Installation -measurements in millimeters-
- Technical data
- Installation and planning notes
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Installation Plan
PDR 908 HP
Heat-Pump Dryer
Always read the operating and installation instructions before setting up,
installing, and commissioning the machine.
This prevents both personal injury and damage to the machine.
Legend:
| Connection required| | Connection optional or required,
depending on model
---|---|---|---
AL| Vented| KLZ| Cooling air intake
ASK| Condensate drain hose| PA| Equipotential bonding and grounding
B| Machine anchoring| SLA| Peak-load connection
EL| Electrical connection| APCL SST| Closed plinth
F| Machine feet, adjustable| APCL OB| Open plinth
KG| Payment system| APCL 001| Washer-dryer stacking kit
KGA| Payment system connection| XKM| Communication module
KLA| Cooling air vent| ZL| Air intake
Machine dimensions – measurements in inches-
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Installation -measurements in inches-
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Washer-dryer stack -measurements in inches-
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Installation -measurements in inches-
* The distances between the machine and the wall are recommendations to
help make it easier to carry out service work. If installation space is
limited, the machine can also be pushed up against the wall.
Machine dimensions – measurements in millimeters-
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Installation -measurements in millimeters-
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Washer-dryer stack -measurements in millimeters-
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Installation -measurements in millimeters-
- The distances between the machine and the wall are recommendations to help make it easier to carry out service work. If installation space is limited, the machine can also be pushed up against the wall.
Technical data
| PDR 908 HP| PDR 908 HP
---|---|---
Drying system| Heat pump| Heat pump
Drum volume| 34.3 gal| 130 l
Capacity| 17.6 lb| 8.0 kg
Door opening diameter| 14 9/16″| 370 mm
Electrical connection (EL )
Standard voltage CND & USA | 2 AC 208-240 V | 0 |
---|---|---|
Frequency | 60 Hz | 60 Hz |
Total rated load | 1.2 kW | 1.2 kW |
Fuse rating | 2 x 30 A | 2 x 30 A |
Wire min. cross-section | 3 x AWG10 | 3 x AWG10 |
Wire with plug NEMA L6-30 | ||
Wire length | 82 3/4″ | 2,100 mm |
Non-standard voltage MAR 208-240 (Marine) | 2 AC 208-240 V | 2 AC 208-240 V |
---|---|---|
Frequency | 60 Hz | 60 Hz |
Total rated load | 1.2 kW | 1.2 kW |
Fuse rating | 2 x 30 A | 2 x 30 A |
Wire min. cross-section | 3 x AWG10 | 3 x AWG10 |
Wire with plug NEMA L6-30 | ||
Wire length | 82 3/4″ | 2,100 mm |
Condensate drain hose (ASK )
Max. drainage temperature | 158 °F | 70 °C |
---|---|---|
Max. transient flow rate | 0.95 gal/min | 3.6 l/min |
On-site hose sleeve for drain hose | 10 x 30 mm | 10 x 30 mm |
Drain hose (internal diameter) | 3/8″ | 10 /DN 10 mm |
Length of drain hose | 59 1/16″ | 1,500 mm |
Max. delivery head (from lower edge of machine) | 39 3/8″ | 1,000 mm |
Potential equalization (PA)
Machine connection (separate kit required)| |
---|---|---
XCI box / XCI AD interface| O| O
Payment system connection (K GA)
Connection of payment systems (with XCI box / XCI AD)| O| O
Communication module (XK M)| |
---|---|---
Communication module XKM 3200 WL PLT| O| O
Installation on machine feet (F )
No. of machine feet | 4 No. | 4 No. |
---|---|---|
Machine foot, height-adjustable with thread | ± 3/16″ | ± 5 mm |
Machine foot diameter | 1 1/4″ | 31.7 mm |
Anchoring g (B )
Anchoring of Miele Plinths
Miele Plinth installation (fasteners included)| o| o
Required anchor points| 4 No.| 4 No.
Wood screws according to DIN 571| 8 x 65 mm| 8 x 65 mm
Rawl plugs (diameter x length)| 12 x 60 mm| 12 x 60 mm
Plinth floor anchoring (to be provided on site)
Machine installation on on-site plinth (concrete or masonry)| o| o
Min. plinth installation footprint (W/D)| 23 5/8″ / 25 9/16″| 600/650 mm
Wood screws according to DIN 571| 6 x 50 mm| 6 x 50 mm
Rawl plugs (diameter x length)| 8 x 40 mm| 8 x 40 mm
| PDR 908 HP| PDR 908 HP
---|---|---
Machine data
Overall machine dimensions (H/W/D)| 33 7/16″ / 23 13/16″ / 30 9/16″|
850/605/777 mm
Casing dimensions (H/W/D)| 33 7/16″ / 23 7/16″ / 29″| 850/596/737 mm
Site-access dimensions (H/W)
Min. site-access opening (excl. packaging)| 35 7/16″ / 23 13/16″| 900/605 mm
Installation dimensions
Side gap| 13/16″| 20 mm
Recommended side gap – washer-dryer stack| 11 13/16″| 300 mm
Recommended distance to the opposite wall from the front of the machine| 39
8/8″| 1,000 mm
Weights and floor loads
Machine weight (net weight)| 161 lb| 73 kg
Max. floor load in operation| 925 N| 925 N
Emissions
Sound pressure level (in accordance with EN ISO 11204/11203)| < 70 dB(A)| < 70
dB(A)
Heat dissipation rate to installation site| 950 W| 950 W
Installation and planning notes
Installation requirements
The tumble dryer should only be connected to a power supply provided in
accordance with all appropriate local and national legislation and
regulations.
In addition, all regulations issued by the appropriate utilities as well as
standards relating to occupational safety and all applicable valid regulations
and technical standards must be observed.
General operating conditions
Ambient temperature in installation room: +35°F to +95 (+2°C to +35°C).
Air drawn in for use in the drying process will be warm when it is expelled
back into the room. You must therefore ensure that the room is sufficiently
ventilated, particularly if the dryer is located in a small room.
Make sure that the room temperature is not too high. If there are other heat-
producing appliances in the room in which the dryer is located, make sure the
room is well ventilated and switch the other appliances off, if possible.
Otherwise, running times and energy consumption could be increased.
Electrical connection
This tumble dryer is supplied with a power cord and plug ready for connection.
The machine may only be connected to an electrical system that conforms to
national and local codes and regulations.
The tumble dryer should never be connected by an extension cable, e.g., power
strips, to avoid the risk of fire.
The data tag indicates the nominal power consumption and the appropriate fuse
rating. Compare the specifications on the data tag with those of the
electrical power supply.
If the machine is hard-wired, a dual circuit breaker must be provided on-site.
When switched off, there must be an all-pole contact gap of at least 3 mm in
the isolator switch (including circuit breakers, breakers, and relays
according to IEC/EN 60947).
The plug connector or isolator switch should be easily accessible at all
times. If the machine is disconnected from the electricity supply, the
isolator must be lockable or the point of disconnection must be monitored at
all times.
New connections, modifications to the system, or servicing of the ground
conductor, including determining the correct fuse rating, must be carried out
by a qualified electrician, as they are familiar with the pertinent
regulations and the specific requirements of the electric utility company.
References to cable cross-sections in the technical data refer only to the
required power cord. Please consult relevant local and national regulations
when calculating any other wire gauges.
Condensate drain hose
The condensed water is pumped away through the drain hose which is located at
the back of the dryer.
The condensate is drained via a drain pump with a 3′ 3 3/8″ (1 m) delivery
head. For the water to drain freely, the hose must be installed free of kinks.
The swivel elbow at the end of the hose can be turned in either direction or
removed as needed.
In certain situations, this tumble dryer must be equipped with a non-return
valve (optional accessory). Without a non-return valve, water could flow back
into the tumble dryer or be drawn back and leak out. This can cause damage.
Drainage options:
-
Direct connection to a plastic drain pipe with a rubber sleeve.
Use a non-return valve if the end of the hose could possibly become submerged in water. -
Connected securely to a sink with a plastic nipple.
Always use a non-return valve. -
Connected securely to a floor drain (gully).
Always use a non-return valve. -
Directed into a sink or basin.
Secure the drain hose carefully (e.g., by tying it) to make sure it cannot slip. Otherwise, water may escape and cause damage.
Use a non-return valve if the end of the hose could possibly become submerged in water.
Equipotential bonding and grounding
If necessary, an equipotential bond with a good contact connection must be
provided in accordance with all appropriate national and local regulations.
Connection material for equipotential bonding and grounding must be provided
on-site or using a kit available from Miele Technical Service.
Peak load/Energy management
The tumble dryer can be connected to a peak-load or energy-management system
using an optional kit.
When the peak-load function is activated, the heating is deactivated.
A message appears in the display to inform you of this.
Payment system
The tumble dryer can be equipped with a single-machine payment system as an
optional accessory using an optional kit (XCI box / XCI AD).
The programming required for connecting a payment system can be carried out
during the initial commissioning process. After initial commissioning, changes
may only be carried out by your Miele dealer or Miele Technical Service.
Interface
The tumble dryer can be installed with an XKM 3200 WL PLT communication
module.
This module can be used as a WiFi or LAN interface.
The LAN interface provided via the module complies with SELV (Safety Extra Low
Voltage) in accordance with EN 60950. Connected appliances must also comply
with SELV. The LAN connection uses an RJ45 connector in accordance with
EIA/TIA 568-B.
Installation and anchoring
The machine must be installed on a perfectly smooth, level, and firm surface
which is able to withstand the quoted loads.
The floor load created by the machine is concentrated and transferred to the
installation footprint via the machine’s feet.
The tumble dryer should be leveled in both directions with the aid of the
adjustable feet.
Plinth installation
The tumble dryer can be installed on a machine plinth (open or box plinth,
available as an optional Miele accessory) or on a concrete plinth to be
provided on-site.
The quality of the concrete and its strength must be assessed according to the
machine load. Ensure that any raised concrete plinth is adequately bonded to
the floor below.
Washer-dryer stack
The tumble dryer can be installed as a washer-dryer stack together with a
Miele Washing Machine. A stacking kit (optional accessory) is required for
this.
Installation of the stacking kit should be performed by Miele Technical
Service or an authorized Miele service technician.
Please have the model and a serial number of your machine available when
contacting Technical Service.
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
Fax: 609-419-4241
www.mieleusa.com/professional
proinfo@mieleusa.com
Technical Service & Support
Phone: 800-991-9380
Fax: 800-220-1348
proservice@mieleusa.com
Miele & Cie. KG
Carl-Miele-Straße 29, 33332 Gütersloh, Germany
References
- professional.com.au
- Miele Official UAE | Premium Domestic Appliances Online.
- Miele Professional UK | Discover our Commercial Solutions
- Miele | Home Appliances South Africa
- Miele Professional AU | Discover our Commercial Solutions
- Home
- Miele India | Luxury Home Appliances, Buy Kitchen Appliances Products
- Miele Singapore - Premium and Luxury home appliances
- Miele Professional CA-en | Discover our Commercial Solutions
- Miele Professional US | Discover our Commercial Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>