BRISTAN FZ SHXMMCTFF C (D2) Shower Mixer Bar Instruction Manual
- June 6, 2024
- BRISTAN
Table of Contents
- Specifications
- Tools You’ll Need
- Prior to Installation
- Pack Contents
- Installation
- Isolation
- Operation
- Temperature Setting
- Maintenance – Cartridge Cleaning
- Servicing Intervals
- Spare Parts
- Riser Installation (not supplied with FZ SHXVOCTFF C)
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BRISTAN FZ SHXMMCTFF C (D2) Shower Mixer Bar
Please leave these instructions with the end user
Product Codes: FZ SHXMMCTFF C (D2)
FZ SHXVOCTFF C (D2)
Specifications
Tools You’ll Need
Prior to Installation
All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc.
This product must not be modified in any way as this will invalidate the guarantee.
Full access must be made available for future maintenance/servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This can be checked with the aid of an electronic detector.
If power tools are used do not forget to:
– Wear eye protection
– Unplug equipment after use
If in doubt, contact a registered plumber or your Local Water Authority or the
Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Pack Contents
Supplied with FZ SHXMMCTFF C only
Installation
-
Identify the required position of the valve and prepare the water supply pipes.
Supply pipes should be 150mm apart.
Using the backplate supplied with the wallmount, mark and drill holes.
-
Secure the rubber backplate ure the rubber backplate and backpla and backplate into place. te into place.
-
Secure the isolator ure the isolator onto the backplate o the backplate ensuring the oliv ensuring the olive is positioned o positioned over the ver the pipework correctly. work correctly.
-
Push shrouds to the ush shrouds to the back of the w back of the wall outlet, all outlet, securing them against uring them against the rubber fixing pla the rubber fixing plate.
-
Insert filt Insert filter washer and er washer and secure the shower to ure the shower to the wall mount.
Isolation
-
Remove the concealing emove the concealing cap from the shroud.
-
Rotate the shroud until otate the shroud until the opening aligns with the isola the isolation screw. tion screw.
Turn the screw to isolate urn the screw to isolate the water. Reverse the ater. Reverse the process when turning ocess when turning the water back on.
Operation
To override the 38° pre-set temperature, push the temperature control button
down and turn handle towards you to increase.
Temperature Setting
-
Turn the shower on, letting the temperature stabilise.
-
Remove the cap, screw and temperature handle.
-
Turn cartridge spindle clockwise to decrease the temperature.
Turn cartridge spindleanti-clockwise to increase the temperature.
-
Reverse steps 1-2 to reinstall the cartridge and handle.
Maintenance – Cartridge Cleaning
-
Remove temperature and flow handle.
-
Unscrew the flow valve.
-
Remove adaptor, nut and cartridge.
-
Remove O-rings and soak all components in de-scaler and wash off in clean water. Examine all seals and replace if needed.
Use WRAS approved silicon based grease on all seals.
-
Replace cartridge and turn spindle anti-clock anti-clockwise to maximum o maximum temperature.
-
Replace nut and adaptor.
Ensure the raised side is facing towards the back of the valve.
-
Turn cartridge spindle clockwise to decrease the temperature. Turn cartridge spindle anti-clockwise to increase the temperature.
-
Slide handle onto adaptor and turn clockwise until you meet resistance.
-
Reverse steps 1-2 to reinstall the valve and secure handles.
Servicing Intervals
To reduce the build up of limescale and to ensure this shower works to its maximum performance we recommend this shower is serviced every 6-12 months depending on the hardness of your water.
REMEMBER
To service your product! ✓
Spare Parts
To replace any spare parts for your shower why not scan the below QR Code and
search for your product.
Riser Installation (not supplied with FZ SHXVOCTFF C)
-
Assemble the riser, attaching the hose retainer, slider and both the top and bottom brackets.
-
Use the assembled riser to mark the desired position for the riser on the wall.
-
Drill the marked holes.
-
Slide top bracket onto riser and secure to wall.
-
Insert riser rail into lower bracket and secure to the wall.
-
Slide hose through hose retainer before attaching the handset to the shower.
Troubleshooting
Symptom | Cause | Remedy |
---|---|---|
No flow or low flow rate | Partially closed isolation valve. | Open |
isolation valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too
low.| Increase water flow rate or pressure through system.
Head of water is below the minimum distance required.| 2 meters minimum
required.
Hot or cold water being drawn off elsewhere causing pressure changes or
instantaneous boiler temperature changes.| Do not use other water outlets when
using the taps.
Airlock or partial blockage in the supply pipework.| Flush through pipework to
ensure removal of debris and any airlocks.
Water dripping from shower| This is normal for a short time after using
the shower.| This is caused by residual water tension, the build up of water
in the shower.
If water continues to drip, possibly due to the cartridge| Remove cartridge
and clean, refer to ‘Maintenance’ section before starting any maintenance.
Shower does not turn on| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.
At Bristan, we want to make things as easy as possible for our customers.
That’s why we offer solid guarantees on all our products, effective from the
date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
Read User Manual Online (PDF format)