Product profile

Product components

Midea Faucet Filtration Product components

  1. Filter base
  2. Filter cartridge cover
  3. Mounting nut
  4. Thread adapter
  5. Silicone washer
  6. Stainless steel filter screen
  7. Watter purifier main unit
  8. Purified water and raw water switch display
  9. Key switch

List of parts

Midea Faucet Filtration Filter cartridge x1 Midea Faucet Filtration Universal connector x1
Filter cartridge x1   Universal connector x1    Adapters x6

   Midea Faucet Filtration Teflon tape x1

Accessory kit x1           Teflon tape x1    Instructions for Use x1

Installation precautions

Before using the water purifier, please read this Manual carefully and keep it for future reference.

  1. To avoid damage to your body, use municipal tap water;
  2. During initial use, please let the purified water flow for at least 60 seconds;
  3. Before use every day, please let the purified water flow for at least 10 seconds before use (to drain stagnant water);
  4. When the water purifier is not used for more than two days, please let the purified water flow for at least 60 seconds before use (to keep the water outlet clean);
  5. Please use “Contained Purified Water” as soon as possible. Because there is no residual chlorine in purified water, the bacteria may breed easily, put it into a clean container with a cover and store it in the refrigerator.
  6. Please do not touch the “Purified Water” outlet to avoid bacterial growth;
  7. If there is a lot of turbidity in tap water (e.g. the water tank is cleaned or tap water is not used for a long time, etc.), please allow the tap water to flow for some time before use of “purified water” to shorten the life of filter cartridge;
  8. This product is a household water purifier, please never use it for any purpose other than cooking or drinking;
  9. Never connect a special faucet to other machines such as gas water heaters
  10. Please do not install the machine near flame or high temperature;
  11. When the flow of purified water becomes less, please replace the filter. The filter shall be replaced regularly;
  12. Please press slowly when adjusting the raw water and purified water buttons to avoid damage to the machine body;
  13. When used in areas with high water pressure, please turn down the water flow before using. In case of large flow of water, water purification capacity may be affected, and too high water pressure can cause damage and leakage. The conventional water pressure of the product is 0.1-0.4MPa;
  14. To avoid damage to the container, never freeze the product;
  15. When using “purified water”, never use hot water exceeding 38 degrees. If hot water passes through the water purifier accidentally, there may be temporary smell in water sometimes;
  16. Do not plug the water outlet, or have it connected with other device to avoid damage to the water purifier body;
  17. Do not use steel balls, cleaning agents or aggressive liquids (such as gasoline or alcohol) for scrubbing. These substances may cause product rupture, scars, discoloration or deformation;
  18. Please do not disassemble the water purifier body and the filter (if there is
    to avoid damage to other machines; any abnormality, please refer to the catalog, Page 9: Abnormal condition and troubleshooting).
Precautions in use
  1. Some faucets can not be installed;
    Six adapters and 1 universal connector supplied with the water purifier may be easily mounted on majority of threaded faucets;
    Faucets that cannot be installed are: sprinkler pull-our faucets, faucets with rectangular or elliptical outlets, sensing faucets, or faucets in diameter out of 15-24mm with a throat depth less than 15mm;

  2. The replacement period of a filter may vary with water amount consumed, water quality and water pressure;

  3. It shall not be installed on a hot and cold faucet;

  4. The water purifier shall not be in a position exposed to direct sunlight, as this may cause deformation and discoloration;

  5. Hard water cannot be converted into soft water, and salt (sea water) or metal ions dissolved in water cannot be removed;

  6. The filter cartridge shall be cleaned and replaced on a regular basis.

Installation method

Before installing the water purifier, make sure you have the required faucet mounting adapter.

Install Type A adapter for threaded faucets in diameter of 19.5mm, 21.5mm or 23.5mm.

1. Remove the mounting nut from the main unit.

Midea Faucet Filtration Installation method 1

2. Remove the faucet bubbler, and select the appropriate adapter.

Midea Faucet Filtration Installation method 2

3. With the mounting nut facing up, attach the external thread adapter to the faucet.

Midea Faucet Filtration Installation method 3

4. Tighten the mounting nut to secure the body. Complete.

Midea Faucet Filtration Installation method 4

Install Type B adapter for threaded faucets in diameter of 20.5mm, 21mm or 22.5mm.

1. Remove the mounting nut from the main unit.

Midea Faucet Filtration Installation method type B 1

2. Remove the faucet bubbler, and select the appropriate adapter.

Midea Faucet Filtration Installation method type B 2

3. With the mounting nut facing up, attach the internal thread adapter to the faucet.

Midea Faucet Filtration Installation method type B 3

4. Tighten the mounting nut to secure the body. Complete.

Midea Faucet Filtration Installation method type B 4

Install the universal connector for faucets in diameter of 15-24mm.

1. Remove the faucet bubbler, and select the appropriate adapter.

Midea Faucet Filtration Installation method type C 1

2. With the mounting nut facing up, attach the internal thread adapter to the universal connector.

Midea Faucet Filtration Installation method type C 2

3. Put the universal connector into the faucet and tighten the steel rim with a screwdriver.

Midea Faucet Filtration Installation method type C 3

4. Tighten the mounting nut to secure the body. Complete.

Midea Faucet Filtration Installation method type C 4

Install the water purifying filter.

1. Open the filter cartridge cover, peel off the filter film and reinstall the filter into the filter cartridge.

Midea Faucet Filtration Installation method type D 1

2. Align the filter cartridge connector with the main unit interface.

Midea Faucet Filtration Installation method type D 2
3. Insert the filter cartridge into the main unit interface and fix the filter after rotating it 90 degrees upward.

Midea Faucet Filtration Installation method type D 3
4. Complete.

Midea Faucet Filtration Installation method type D 4

Instructions for use

After installation of the faucet, the tap water is opened, and the water purifier key is switched to the water purification level, with the filtered purified water discharged from the water outlet; after the water purifier key is switched to the raw water level, the unfiltered tap water is discharged from the raw water outlet.

Purified water                           Raw water

Midea Faucet Filtration Instructions for use Purified
water     Midea Faucet
Filtration Instructions for use Raw water

Filter replacement

1. Rotate the filter cartridge 90 degrees backward to remove the filter.

Midea Faucet Filtration Filter replacement 1
2. Open the filter cartridge cover, take out the old filter, peel off the new filter film, and reinstall the filter into the filter cartridge.

Midea Faucet Filtration Filter replacement 2

3. Insert the filter cartridge into the main unit interface fix the filter after rotating it 90 degrees upward.

Midea Faucet Filtration Filter replacement 3

4. Complete.

Midea Faucet Filtration Filter replacement 4

Filter configuration
Filter name Recommended life expectancy Effect Quantity
Carbon fiber filter 6-12 months Efficient filtration of impurities in water,
heterochrome, odor and residual chlorine 1 pc
Basic parameters
Product model MC122-2
Purified water flow 2L/min
Rated total purified water 1200L
Applicable water quality Municipal tap water
Appearance difference White body, blue trim strip
Work pressure 0.1-0.4MPa
Water treatment process map

MC122-2

Midea Filter Water treatment process map

Troubleshooting
Abnormal condition Possible causes Solutions
Main unit head leaks Is it properly installed on the faucet? Re-

install
Is front end of the faucet aging?| Repair the faucet
Is the seal aging?| Change the seal
Water pipe port leaks| Is the water pipe firmly connected?| Reconnect correctly
Main unit body leaks| Is the cartridge hose securely connected?| Reconnect correctly
Water purifier main unit machine whether there is water?| Please wipe with a dry towel
Main unit head leaks| Is the head lock hose nut tight?| Reconnect correctly
Is the main unit head seal washer damaged?| Change the seal
The flow of raw water is less and not uniform| Is there any dirt in the filter screen?| Please rinse with a clean toothbrush disinfected in hot water.
Is raw water outlet clean?
Flow of purified water is less| Is the water supply hose bent?| Please restore the water supply hose.
It is possible that the filter is clogged| Please replace the filter (the flow of water will be reduced when water pressure is low).
Smell| Is the filter in place?| Please carry out installation in the correct method.
Is the filter in place?| Please replace the filter.