MIPRO ACT580H Digital Handheld Transmitter User Guide

June 6, 2024
MIPRO

MIPRO logo

(ACT-800H UHF Digital
ACT-700H/ACT-500H/ACT-300H UHF Analog
ACT-240H/2.4GHz, ACT-58(8-175.8GHz Digital
Handheld Wireless Microphone
User Guide 0 °

This Confidential document is for the purposes of repairing MIPRO products only. Sp forbidden to modify, add, sell, print, copy, improperly use or offer to third parties. Otherwise, MIPRO will reserve the right to proceed with legal action

Handheld Wireless Microphone

All rights reserved. Do not copy or forward without prior approvals MIPRO.
Specifications and design are subject to change without notice. YM 021/05

  1. Microphone  Capsule Module
  2. Upper Housing
  3. LCD Panel
  4. Power Switch
  5. Mute Button
  6. Power Switch  Block Latch
  7. (ACT-800H / ACT-700H only) SET Button
  8. MODE Button
  9. Battery Holder
  10. USB Type-C Nicc: Charging Port
  11. Charging Indicator
  12. ACT Sync Window
  13. Rear Cap
  14. Lower Housing,
  15.  Channel Identification Ring

II. Battery Insertion and Replacement

  1.  Battery Insertion. Fig. 2: (A) Turn to detach the lower housing 0. (B) Insert one 18500 lithium battery or two M batteries. (C) 18500 lithium battery insertion: insert one into the left holder with + pole upward. (D) AA batteries insertion: insert one into the right holder with — pole upward, and then insert another into the left holder with + pole upward.
  2. Check battery polarity was inserted correctly if battery power is sufficient but unable to turn on the transmitter.
  3. Power off to conserve battery power. Remove the battery when it will not be used for an extended period of time.

|
---|---

4. This device can charge only one ICR-18500 lithium battery via USB Type-C. Cautions during charging:
(A) Before charging, make sure the inside battery is an ICR-18500 lithium battery.
(B)Confirm the battery polarity is inserted correctly.
(C) Turn off the power first and then charge.
(D) Do not charge AA batteries or NiMH batteries. Any damage caused by incorrect batteries is excluded from the warrant
(E) The charging port doesn’t supply the power ft* the device. . e”
(F) Do not remove the lithium battery during charging status. Detach the charging cable before removing the lithium battery.
(G) Indicator: Amber (charging); C) Green (full).
(H) Check the 18500 lithium battery inserted correctly if the indicator doesn’t glow.

Operating Instructions

  1.  Power On/Off (A) Push the power switch upward to turn on. The LCD panel glows when power is on. Push the power switch downward to turn off. Fig. 3, 4
    (B) The LCD shows OFF… during power off. Fig. 5

MIPRO ACT580H Digital Handheld Transmitter sat button

  1. Press the MODE button to select functions.

  2. Press the SET button, the parameter blinks, press the SET button again to change the parameter. Fig. 3

  3. Battery Level Status: Replace with a charged battery once the level falls to 10%. The device will power off automatically with an OFF message once the power level falls too low. Fig. 6

  4. How to Prevent from Accidental Power On/Off: (ACT-800H / ACT-700H only)
    To prevent users from powering off the microphone F\ accidentally, switch the Power Switch Block Latch(+t left to block the power switch. Fig. 7 AC)
    MIPRO ACT580H Digital Handheld Transmitter - power
    Switch the latch left to block the power switch Fig. 7

IV. LCD and Operating Instructions

1. LCD Display. Fig. 7:
MIPRO ACT580H Digital Handheld Transmitter - fig9
Functions
Parameters
Battery Status
Audio Signal Level Bar
2. ACT-800H LCD. Fig. 8:
(A) Group (GRP) I Channel (CH) I Frequency (FREQ.). Fig. 9:
(1) Group / Channel / Frequency is synced,cre from the receiver, and cannot be changed.
(2) To change Group / Channel / Frequency, do it at the receiver and then press the ACT CP button to sync. ![MIPRO ACT580H Digital Handheld Transmitter

(3) The specific group and channel set via PC will display X – X I . Fig. 10

MIPRO ACT580H Digital Handheld Transmitter - display6
(B) AF L-CUT: AF Low-Cut Setting. Fig. 11.
(1) Select L-CUT or FLAT.
(2) L-CUT: the frequency response at 100Hz will decrease about 3dB with a slope of -6d B/Octave.
MIPRO ACT580H Digital Handheld Transmitter - battary
(C) AF LIMIT: Audio Input Limit Setting. Fig. 12 (1) Select YES or NO. (2) YES: the maximum output of the receiver is limited to 1V.
MIPRO ACT580H Digital Handheld Transmitter - fig11
(D) ENCRYPTION: Display Encryption Information. Fig. 13 The ENCRYPTION function must be set at the receiver first then using ACT to program the transmitter. (Refer to ENCRYPTION function of the receiver,
MIPRO ACT580H Digital Handheld Transmitter - fig12
(E) RF POWER: RF Power Setting. Fig. 14
(1) Select HIGH or LOW.
(2) HIGH has 50mW transmitting power. LOW has 10mW transmitting power. Set appropriate power to meet region/country regulations.
MIPRO ACT580H Digital Handheld Transmitter - fig13

(F) MUTE MODE: Mute Setting. Fig. 15
(1) Select MAN, AUTO or DIS.
MIPRO ACT580H Digital Handheld Transmitter - mute
(2) MAN (Manual): the mute function is controlled by the MUTE button. Fig. 16
(a) Press the MUTE button to mute the transmitter and the Audio Signal Level Bar **19** shows AF MUTE and blinks. 2 Press again to unmute and the blink stops.
(b) AF MUTE will be disabled automatically when power is off.

MIPRO ACT580H Digital Handheld Transmitter - fig14

3. AUTO (Automatic): the mute button has no effect. The handheld transmitter microphone determines to MUTE and UNMUTE automatically.
(a) Audio mutes automatically when the microphone head points toward the floor (down). Audio unmutes automatically when the microphone dit>C1 head points toward roof (up).
(b) Audio is muted automatically if sitting idled for over 4 seconds. Audio is unmuted when moved.
(4) DIS (Disabled): Mute is disabled and can NOt\ be muted in any method.

(G) Error codes:

  1.  ROM-ER -> Channel wasn’t programmed or internal data error.
  2. ERROR1 -+ RF frequency targeting circuitry is failed.
  3. NO—-03 -> The set frequency exceeds the upper band. The transmitter frequency will not be changed but it can be operated as long as the power switch is toned on again.
  4. NO—-04 NC The set frequency exceeds the ICT lower band. The transmitter frequency will not be changed but it can be operated as long as the power switch is turned on agin.

(H) MUTE Button. Fig. 17:

  1.  Press the MUTE button to enter MUTE status, t\’ the Audio Signal Level Bar 0 shows # AFMUTE and blinks, and all operations 9 and the ACT function are still workable.
  2. Press the MUTE button again to unmute. AF rQMUTE will be disabled automatically when 10 2 power off. ‘
  3. The MUTE button is only workable under MAN (Manual Setting) mode.MIPRO ACT580H Digital Handheld Transmitter - fig17

ACT-240H / ACT-580H LCD:

GR (Group) — CH (Channel) — ID (ID Code). Fig. 18:

  1.  Group / Channel / ID Code messages are ,c)!\ displayed only and cannot be changed.

  2. To change Group / Channel / ID Code, do it at the receiver and then press ACT button to sync.

  3.  ACT-240H: GROUPStH 1-12, ID 1-6•1 ACT-580H: GROUP A, B1, B2, CH 1-12, ID 1-64, and GO pairing mode.

 ACT-700H / ACT-500H / ACT-300H LCD. Fig. 19:

MIPRO ACT580H Digital Handheld Transmitter - fig19

(A) Group (GRP) / Channel (CH) / Frequency (FREQ.). Fig. 20:

  1. Group / Channel / Frequency messages are displayed only and cannot be changed. 4-)

  2. To change Group / Channel / Frequency, do it at the receiver and then press ACT button to sync.
    MIPRO ACT580H Digital Handheld Transmitter - fig22

  3.  For those specific channels set via PC, the screen shows only CHANNEL and numbers. Fig. 21

(B) RF POWER Setting. Fig. 22: et9 :0* Select RF-HI or RF-LOW.
(C) MUTE MODE Setting. Fig. 23: 0g.5
(1) Select MANUAL or DISABLE.
(2) MANUAL: Use the MUTE button to mute/unmute.
(3) DISABLE: MUTE button is disabled. The mute setting is canceled.

(D) Error Codes:

  1. ( ERR no01EEPROM Channel wasn’t programmed or internal data error.
  2. ERR no02  for testing only.
  3. ERR no03 the set frequency exceeds the upper band. The transmitter frequency will not be changed but it can be operated as long as the power switch is turned on again
  4.  ERR no04  the set frequency exceeds the excv lower band. The transmitter frequency will 00 not be changed but it can be operated as ). long as the power switch is turned on again.

(E) MUTE Button. Fig. 24:

  1. Press the MUTE button to enter mute status.
  2. Press MODE, SET buttons to select parameters. Idle for 5 seconds and return to MUTE mode.
  3. Press the MUTE button again to unmute.
  4. Unmute Mode: The screen shows UNMUTE for 1 second and returns to Home Screen.
  5. The MUTE button is only workable under MANUAL mode.
    MIPRO ACT580H Digital Handheld Transmitter - fig26

V. Cautions

  1. Turn off to save battery life when not in use. Remove the battery not used for an extended period of time.
  2. To improve the efficiency of the transmitting antenna, do not cover the hands over the rear housing section.
  3. To prevent degraded microphone sound quality, directionality, and annoying feedback, do not cover the hands over the microphone grille.
  4. Correct posture of holding the handheld microphone is required because the distance between the microphone and the mouth will have a significant impact on the sensitivity and sound quality.
  5. Keep the microphone grill clean and unblocked to enhance pick-up sound quality.

VI. Notes

  1.  Refer to the actual product in the event of product description discrepancy.
  2. Frequency range, RF output power, and maximum deviation comply with the 643 regulations of different countries.

Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV techni”i for help.

FCC Caution : To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example – use only shielded interface cables when connecting to computer or peripheral devices).
FCC Radiation Exposure Statement
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 0.5 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antennas used for this transmitter must be installed to provide a separation distance of at least 0.5 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1.  This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

MIPRO ACT580H Digital Handheld Transmitter -icon

MIPRO Electronics Co., Ltd
Headquarters: No. 814, Beigang Rd., Chiayi City 600079, Taiwan
Tel: +886.5.238.0809
Fax: +886.5.238.0803
www.mipro.com.tw
mipro@mipro.com.tw

MIPRO ACT580H Digital Handheld Transmitter - bar
All rights reserved. Do not copy or forward without prior approvals MIPRO. Specifications and design are subject to change without notice. YM 021/05

Documents / Resources

| MIPRO ACT580H Digital Handheld Transmitter [pdf] User Guide
ACT580H, M5X-ACT580H, M5XACT580H, ACT580H Digital Handheld Transmitter, Digital Handheld Transmitter, Handheld Transmitter, Transmitter
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MIPRO User Manuals

Related Manuals