Mosentek MS009ER 10mm Thickness Super Compact Sensor Instruction Manual

June 6, 2024
Mosentek

ModelMS009ER
Focus on Intelligent lighting
10mm thickness super compact sensor

Features

  • Super compact sensor module WLH 18.54210mm
  • Remote control setting
  • 5V PWM dimming control
  • Daul PD for auto lux on/off

Technical data

Input Operating voltage 12VDC
Operating current ≥40mA
Output 5V PWM
Output Microwave frequency 5.8GHz±75MHz
Sensor Parameters Microwave power <0.3mW
Detection angle 30°-150°
Sensitivity 100%/75%/50%/25% (Refer to Remote Control)
Hold time 5s/1min/3min/10min (Refer to Remote Control)
Daylight threshold 10Lux/25Lux/50Lux/Disable (Refer to Remote Control)
Stand-by period 0s/10s/10min/+∞ (Refer to Remote Control)
Stand-by dimming level 20%/30% (Refer to Remote Control)
Mounting height Max.5m (ceiling mounted); 1.5-1.8m (Wall Mounted )
Detection range Radius, Max.6m (ceiling mounted); Max.10m (Wall Mounted 1.8 )
Operating temperature -25°C~70°C
Size (LWH) 4824.512 mm
Warranty 5 years
Other

Dimension (Unit: mm)

Wiring diagram

Detection coverage

Daylight Priority

Thanks to the Dual-PD technology, The sensor can tell the difference between natural light and artificial LED light, the sensor will turn on your light fixtures when the ambient light is lower than the setting value even there is no motion was detected. When the ambient light is up to the setting value, the sensor will switch off the light fixtures even there is still motion.

Note: Lux-Off sampling time–10s;
Lux-Off sampling time–10s;
The lux-On function takes effect only when the standby dimming period is set at +∞.

Application

Daylight priority
The lux-On function takes effect only when the stand-by dimming period is set at +∞.

With sufficient daylight, even when motion is detected, the light remains OFF.

Light automatically on and dim to the stand-by dimming level when the ambient brightness is lower than the preset lux level.

With insufficient ambient brightness, the light dims to 100% when motion was detected.

Light keeps on 100% within the hold time.

The light dims to standby level if no motion is detected after holdtime.

Light off when ambient lux level is higher than preset lux amount even there is still motion.

ON/OFF function

The daylight threshold is set to “10Lux/25Lux/50Lux, Stand-by period is set to “0s”.

With sufficient daylight, even when motion is detected, the light remains OFF.

With insufficient ambient brightness, the light dims to 100% when motion was detected.

Light keeps on 100% within the holdtime.

After the last detection and the preset hold time elapsed, light OFF.

The daylight threshold is set to “Disable”. Light on when detect movement, After people leave, Light off after a stand-by period.

When motion is detected, the sensor will switch on the light to 100% brightness.

After people leave the detection area, the light remains 100% brightness within hold time.

After the last detection and the present hold time elapsed, light OFF.

Dimmable control/Corridor function

The daylight threshold is set to “10Lux/25Lux/50Lux, the stand-by period is set to “10s/10min”.

With sufficient daylight, even when motion is detected, the light remains OFF.

With insufficient ambient brightness, the light dims to 100% when motion was detected.

Light keeps on 100% within the holdtime.

Light dims to standby level if no motion is detected after holdtime.

After the stand-by period, light OFF.

Application

  • Train station, Airport, etc.
  • Industrial Lighting: Factory, Warehouse, etc.
  • Commercial Lighting: Office, Supermarket, etc.
  • Public Lighting: Residence, Hospital, School, Metro station

Installation precautions

  • Wiring must be strictly in accordance with the wiring diagram to avoid short circuits.
  • The detected surface cannot be shielded by metal objects.
  • A microwave sensor can be installed in any lamp except the one with a full metal shell.
  • Should be kept away from the driver to avoid interference generation and lamp flashing.
  • Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.
  • Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.

Caution:
This device complies with Part 15 of the FCC rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment. This radio transmitter (identify the device by certification number or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirements.
To maintain compliance with FCC’s RF exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
5G
For the 5725-5875 frequency band, Operations in the 5725-5875 band is restricted to indoor usage only.

Shenzhen Mosentek Technology Co., Ltd.
Add Building No. 3, Room 202, Shannen community No. 3 industry park, Yanluo Street, Baoan District, Shenzhen, P.R.C.
Email: sales@mosentek.com
Tel: +86 0755 2720 6813