Mosentek MS036 Panel Light Microwave Motion Sensor Instructions

June 16, 2024
Mosentek

Mosentek MS036 Panel Light Microwave Motion Sensor Instructions
Light Microwave Motion Sensor

Features

  • 5.8GHz dimming microwave motion sensor
  • DC input, PWM dimming output control
  • Compact size configuration suitable for panels; troffer; linears
  • Remote control setting.
  • 5 years warranty.

Technical data

Input Operating voltage 11-15VDC
Operating current 22mA
Output Output PWM
PaSraemnseotrers Microwave frequency 5.8GHz±75MHz
Microwave power <0.3mW
Detection angle ≤150°
Sensitivity 100%/75%/50%/25% (Refer to Remote Control)
Hold time 3s/30s/90s/3min/5min/15min/20min/30min (Refer to Remote Control)
Daylight threshold 5Lux/15Lux/50Lux/100Lux/300Lux/Disable (Refer to Remote

Control)
Stand-by period| 0s/5s/30s/3min/5min/15min/45min/+∞ (Refer to Remote Control)
Stand-by dimming level| 10%/20%/30%/50% (Refer to Remote Control)
Mounting height| Max.5m (ceiling mounted); 1.5-1.8m (Wall Mounted)
Detection range| Radius, Max.5m (ceiling mounted); Max.10m (Wall Mounted 1.8m)
Operating temperatureIP rating| -25°C~70°C
Warranty| IP44
| 5 years
Other|

Mechanical structure (Unit: mm)

Mechanical structure \(Unit: mm\)

Wiring diagram

Detection coverage

Sensitivity : 25% 50% 75% 100%

Application

ON/OFF function

  1. 1). The daylight threshold is set to “5Lux/15Lux/50Lux/100Lux/300Lux, Stand-by period is set to “0s” .
    With sufficient daylight, even when motion detected, light remains OFF.

With insufficient ambient brightness, light dims to 100% when motion was detected
.
Light keeps on 100% within the holdtime.

After the last detection and the preset hold time elapsed, light OFF.

  1. The daylight threshold is set to “Disable”. Light on when detect movement, After people leave, Light off after hold time.
    When motion is detected, the sensor will switch on the light to 100% brighteness.

After people leave the detection area, light remains 100% brightness within hold time.

After the last detection and the present hold time elapsed, light OFF.

Dilemma control/Corridor function

The daylight threshold is set to “5 Lux/lux/lux/100Lux/300Lux, stand-by period is set to “5/30s/min/min/minim/minim”.

With sufficient daylight, even when motion detected, light remains OFF

With insufficient ambient brightness, light dims to 100% when motion was detected .

Light keeps on 100% within the hold time

Light dims to standby level if no motion detected after holdtime.

After the stand-by period, light OFF.

Installation precautions

  • Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
  • The detected surface cannot be shielded by metal objects.
  • Microwave sensor can be installed in any lamp except the one with full metal shell.
  • Should be kept away from the driver to avoid interference generation and lamp flashing.
  • Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.
  • Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.

MR003 Programable one key commission remote controller

Key Function
ON/OFF Setting the light permanent ON or OFF without motion mode
Auto Switch to sensor mode and restore the latest sensor setting
Reset Turn the sensor in a default setting(3s hold time, 0s stand-by period,

lux disable, 100% sensitivity).
Power (80%/100%)| Quick setting the power output in 80% or 100%
Brightness (+/-)| Long press this button to set the power from 20% to 100%,available in permanent ON mode or in sensor mode.
Start| Program Mode| 1. Press Start to program mode,then select the ①Sensitivity② Holdtime③Standby dimming level④Standby period⑤Daylight threshold to setting2. Press Memory to save the parameters ①-⑤ had selected in step 13. Press Apply to transmit the ①-⑤ parameters to the target sensor Remark:After press Start,you need to press any of ①-⑤parameter button within 30S, the time windown between press any button is 30S , it will quit program mode if no any button is pressed within 30S.
Memory| Save Setting
Apply| One Key Apply
Sensitivity| In this area, movement will be detected and able to trigger the sensor. 100% detection area is also known as the strongest sensitvity.
Hold time| The period of light keeping 100% brightness after moving objects leave the detection area.
Stand-by dimming level| The dimming level in the standby period.
Stand-by period| The period of light keeping low output before it’s completely switched off. When it’s preset as”+∞“, the light always keep at low output if no movement in the detection area and doesn’t turn off.
Daylight threshold| Definition of the ambient brightness; when the ambient brightness is lower than the preset specific lux amount, the sensor will work; when it’s preset as “disable”, the sensor will detects motion regardless the ambient brightness.

zemote Setting Tips: When press any button, if the light is flickering one time, means the setting
is successful.

Size (LWH): 116.55513mm
AAA battery is recommended

FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Note : The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user’s authority to operate the equipment

The device has been evaluated to meet general RF exposure requirement.
To maintain compliance with FCC’s RF exposure guidelines, the distance must be at least 20 cm
between the radiator and your body, and fully supported by the operating and installation