Mosentek MD001E 5.8GHz Microwave Motion Sensor Switch
Product Information
Specifications:
- Product: 5.8GHz Microwave Motion Sensor Switch
- Models: MD001E, MD001EB
- Operating Voltage: 100-277VAC 50/60Hz
- Switching Capacity: Max. 400W @220VAC
- Warranty: 5 years
Product Usage Instructions
Installation:
- Ensure the power supply is turned off before installation.
- Mount the sensor switch at the desired height and angle for optimal detection range.
- Connect the wires according to the provided wiring diagram.
- Turn on the power supply and test the sensor switch functionality.
Setting up the DIP Switch:
For MD001E model with front DIP switch:
- Use a small tool to set the DIP switches as per your desired settings.
- Refer to the user manual for different switch configurations and their corresponding functions.
For MD001EB model with back DIP switch:
- Access the back of the sensor switch to adjust the DIP switches.
- Follow the provided guidelines to set the switches based on your requirements.
Calibration:
Adjust the sensitivity, hold time, and daylight threshold settings as
needed for your specific application.
Maintenance :
Regularly check for any obstructions or dirt that may affect the sensor’s
performance. Clean if necessary.
Frequently Asked Questions (FAQ):
-
Q: What is the detection range of the sensor switch?
A: The detection range is adjustable but typically ranges from [specific range] depending on the mounting height and environmental factors. -
Q: Can the sensor switch be used outdoors?
A: Yes, the sensor switch is suitable for outdoor use with its IP rating providing protection against dust and water ingress.
Model: MD001E
Enabling Technology Serving People
5.8GHz Microwave Motion Sensor Switch
- PEODUCT.: 5.8GHz Microwave Motion Sensor Switch
- MODEL NO.: MD001E, MD001EB
- SPEC NO.:
R & D DEPARTMENT
WRITED BY| CHECKED| APPROVED
| |
Features
- 100-277VAC Input voltage.
- 2 structures for selection: front side DIP switch: MD001E; back side: MD001EB.
- 5 years warranty.
Technical data
Input | Operating voltage | 100-277VAC 50/60Hz |
---|---|---|
Switching capacity | Max. 400W @220VAC | |
Stand-by power | <0.5W | |
Output | Output | ON/OFF |
Sensor Parameters | Microwave frequency | 5.8GHz±75MHz |
Microwave power | <0.3mW | |
Sensitivity | 100%/75%/50%/25% | |
Hold time Daylight threshold | 5s/1min/3min/10min Disable /50Lux/25Lux/10Lux | |
Mounting height | Max.6m (Ceiling mounted); 1.5-1.8m (Wall Mounted) | |
Detection range | Radius Max.6m (Ceiling mounted 3m); Max.10m (Wall Mounted |
1.8m)
Detection Angle| 30°-150°
Operating temperature| -35°C~70°C
Other| IP rating| IP20
size (LWH)| 8036.526mm
Warranty| 5 years
|
Note| Default setting: Sensitivity 100%, Hold time 5s, Daylight threshold
Disable.
Mechanical structure (Unit: mm)
Wiring diagram
Attention: The switch is designed for connecting a single loading, it will affect the lifetime if connecting more than one loading.
Detection coverage
Settings
- In this area, movement will be detected and able to trigger the sensor. 100% detection area is also known as the strong sensitivity.
- The period of light keeping 100% brightness after moving objects leave the detection area.
- Definition of the ambient brightness; only when the ambient brightness is lower than the preset specific lux amount, the sensor will work; when it’s preset as “disable”, the sensor will detects motion regardless the ambient brightness.
Application
Automatically ON/OFF function:
- The daylight threshold is set to “10Lux/25Lux/50Lux”.
- With sufficient daylight, even when motion detected, light remains OFF.
- With insufficient daylight, when motion detected, light ON.
- After people leave the detection area, light remains 100% brightness within hold time.
- After the last detection and the preset hold time elapsed, light OFF.
- The daylight threshold is set to “Disable”. Light on when detect movement, After people leave, Light off after hold-time.
- When motion is detected, the sensor will switch on the light to 100% brightness.
- After people leave the detection area, light remains 100% brightness within hold time.
- After the last detection and the present hold time elapsed, light OFF.
Applications
Installation precautions
- Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
- The detected surface cannot be shielded by metal objects.
- Microwave sensor can be installed in any lamp except the one with full metal shell.
- Should be kept away from the driver to avoid interference generation and lamp flashing.
- Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.
- Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Note:
-
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
-
Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user’s authority to operate the equipment.
-
The device has been evaluated to meet general RF exposure requirement.
-
To maintain compliance with FCC’s RF exposure guidelines, the distance must be at least 20 cm
between the radiator and your body, and fully supported by the operating and installation
Add: Block H 5F; Huamingchen Hi-Tech Industry Park; Genyu Road; Matian