GENELEC 8320A Two Way Smart Active Monitors User Manual
- October 27, 2023
- GENELEC
Table of Contents
GENELEC 8320A Two Way Smart Active Monitors
General Description
Genelec 8320A and 8330A are two-way smart active monitors designed for demanding professional applications. Genelec Smart Active Monitor™ (SAM™) digital signal processing (DSP) built inside each smart active monitor with Genelec Loudspeaker Manager™ (GLM™) software provides unparalleled acoustic quality, ease of use, and high monitoring accuracy even in difficult acoustic environments. The high-performance drivers are directly connected to dedicated D Class power amplifiers. System protection is implemented as a part of the SAM signal processing. The MDE™ (Minimum Diffraction Enclosure™) enclosure is made of die-cast aluminum and shaped to reduce edge diffraction. Combined with the advanced Directivity Control WaveguideTM (DCWTM), this design contributes to excellent acoustic neutrality.
Delivery Contents
Each monitor is supplied with a mains cable, 5 meter RJ45 cable, and an
operating manual.
Connections
Before connecting, switch off the monitors and the signal source. Once all the
connections have been made, the monitors can be switched on.
Mains Power
The power switch is located on the back panel (see Figure 2). Connect the
monitor to a mains socket having a protective earthed connection. Do not
connect to an unearthed mains supply or using an unearthed mains cable. These
monitors feature an universal mains voltage and can be connected to any
voltage between 100-240 VAC 50-60 Hz.
GLM Network Connection
Up to 30 monitors and subwoofers can be connected to a computer using the GLM
Adapter. An RJ45 cable is supplied for this. Start control network cabling
from the GLM Adapter to the first monitor. Continue daisy-chaining to all
monitors and subwoofers (see Figure 3). No special sequence is necessary.
Analog Audio Input
The analog audio input on both models accepts a balanced male XLR connector.
Digital Audio Input
The 8330A digital audio input (DIGITAL IN) accepts a male XLR connector
carrying an AES/EBU formatted digital audio signal. The digital audio can be
routed to the next monitor or subwoofer using an XLR output (DIGITAL OUT). The
AES/EBU digital audio subframe A or B is selected using the GLM software.
Settings and Acoustic Calibration
The Smart Active Monitors are extremely flexible
in compensating the acoustic influences of the room and support automated
setup using the GLM User Kit and software. The 8320A and 8330A are compatible
with GLM 2.0 and later.
The GLM software can be downloaded from Genelec web site
(www.genelec.com/glm). The GLM 2.0 User Kit is needed for the setup. The User
Kit contains the GLM Adapter and GLM measurement microphone.
The GLM Adapter is connected to the computer USB port and the GLM network. The
GLM measurement microphone is placed at the listening location.
Execute the setup process in the GLM software to align and set up the Smart
Active Monitors and Subwoofers as a system. After calibration, keep the
computer connected to maintain the settings or save the settings to the Smart
Active Monitors using the GLM software.
ISSTM Autostart Function
Intelligent Signal SensingTM (ISSTM) enables very low standby power
consumption, less than 0.5 watts.
As a factory default, the ISS function is disabled. The ISS function can be
enabled by clicking the “ISS Power Saving” pulldown menu in the GLM software.
This menu also provides a selection of the time before entering standby. The
playback resumes once an input signal is detected. There is a slight delay
before playback resumes.
Mounting Considerations
Align the Monitors Correctly
Place and point the monitors so that their acoustic axes (see figure 1) are
aimed towards the listening position. Vertical orientation is preferred, as
this minimises the sound colour change around the crossover frequency when the
listener is moving horizontally.
Maintain Symmetry
Place the monitors at an equal distance from the listening position and
symmetrically relative to the room walls. Place the listening position on the
room front-back centreline and the monitors at an equal distance from this
centreline.
Minimise Reflections
Acoustic reflections are created by objects close to the monitors. Such
objects can be desks, cabinets, computer monitors etc. Acoustic reflections
can cause unwanted sound colouration and sound image instability. These can be
minimised by placing the monitors and the listening position clear of
reflective surfaces.
Minimum Clearances
Sufficient clearance for amplifier cooling and reflex port function must be
ensured. The surroundings of the monitor must be open to the listening room
with a minimum clearance of 3 centimeters (13/16 in) behind, above, and on
both sides of the monitor. The ambient temperature may not rise above 35
degrees Celsius (95°F.)
Mounting Options
The Genelec 8320A and 8330A offer several mounting options: The Iso-Pod™
(Isolation Positioner/Decoupler™) vibration insulating stand allows tilting of
the monitor to correctly align the acoustic axis. The bottom of the monitor
has a 3/8 in UNC threaded hole compatible with a standard microphone stand.
The rear has two M6 x 10 mm threaded inserts for wall or ceiling mount
brackets. Genelec offers a wide variety of mounting accessories. Please
consult Genelec web site or your nearest Genelec dealer.
Maintenance
No user serviceable parts are inside the monitor. Maintenance and repair must
only be undertaken by qualified service personnel.
Safety Considerations
The 8320A and 8330A have been designed in accordance with international safety standards. The following warnings and cautions must be observed to ensure safe operation and to maintain the monitor under safe operating conditions:
- Servicing must only be performed by qualified service personnel. The monitor must not be opened.
- Do not use the monitor with an unearthed mains cable or an unearthed mains connection.
- Do not expose the monitor to water or moisture. Do not place any objects filled with liquid, such as vases, on the monitor or near it.
- This monitor is capable of producing sound pressure levels in excess of 85 dB, which may cause permanent hearing damage.
- Free flow of air behind the monitor is necessary to maintain sufficient cooling. Do not obstruct airflow around the monitor.
- The device is not completely disconnected from the AC mains service unless the mains power cord is detached from the device or the mains outlet.
Guarantee
This product is guaranteed for a period of two years against faults in
materials or workmanship. Refer to supplier for full sales and guarantee
terms.
Compliance to FCC Rules
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
This device may not cause harmful interference, and this device must accept
any interference received, including interference that may cause undesired
operation.
Note : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit
- different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
-
-
-
-
-
- Modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment under FCC rules.
-
-
-
-
Figure 4: Horizontal and vertical directivity plots of the 8320A and 8330A.
SYSTEM SPECIFICATIONS
| 8320| 8330
Frequency range –6 dB:| 55 Hz – 23 kHz| 45 Hz – 23 kHz
Accuracy of frequency response:| ±1.5 dB (66 Hz – 20 kHz)| ±1.5 dB (58 Hz – 20
kHz)
Maximum short term sine wave acoustic output on axis in half space, averaged
from 100 Hz to 3 kHz:| > 100 dB SPL| > 104 dB SPL
Maximum long term RMS acoustic output in same conditions with IEC weighted
noise (limited by driver unit protection circuit):| > 94 dB SPL| > 96 dB SPL
Maximum peak acoustic output per pair, at 1 m distance with music material:| >
107 dB| > 110 dB
Self generated noise level in free field on axis:| < 5 dB (A-weighted)
Harmonic distortion at 85 dB SPL on axis:| 50…200 Hz < 3 %
200 Hz < 0.5 %
| 50…100 Hz < 2 %
100 Hz < 0.5 %
Drivers:
Woofer Tweeter
|
105 mm (4 in) cone
19 mm (3/4 in) metal dome
|
130 mm (5 in) cone
19 mm (3/4 in) metal dome
Weight:| 3.2 kg (7.0 lb)| 5.1 kg (11.2 lb)
Dimensions:
Height including Iso-Pod™ table stand Height without Iso-Pod™ table stand Width
Depth
|
242 mm (91/2 in) 230 mm (91/16 in)
151 mm (6 in)
142 mm (55/8 in)
|
299 mm (1113/16 in)
285 mm (111/4 in)
189 mm (77/16 in)
178 mm (7 in)
AMPLIFIER SECTION
Bass amplifier short term output power Treble amplifier short term output power| 50 W
50 W
Total harmonic distortion at nominal output| <0.05%
Mains voltage| 100-240 VAC, 50-60 Hz
Power consumption (ISS active / idle / maximum)| < 0.5 W / 3.0 W / 50 W
INPUT SECTION
Digital AES/EBU audio signal connectors (Single wire)| n/a| XLR female IN XLR
male OUT
Input word length| n/a| 16 – 24 bits
Input sampling rate| n/a| 32 – 192 kHz
Crossover frequency| 2.9 kHz
Analog input (load impedance)| XLR female (10 kOhm, balanced)
Analog input level for 100 dB SPL output at 1 meter| -6 dBu (adjustable in GLM
software)
Maximum analog input| 24 dBu
GLM Control network connectors| 2 x RJ45
International enquiries
- Genelec, Olvitie 5
- FI 74100, Iisalmi, Finland Phone +358 17 83881
- Fax +358 17 812 267
- Email genelec@genelec.com
- In Sweden
- Genelec Sverige Tureholmsvägen 12
- 125 35 Älvsjö
- Sweden
- Phone +46 8 449 5220
- Email sweden@genelec.com
- In the USA
- Genelec, Inc., 7 Tech Circle Natick, MA 01760, USA
- Phone +1 508 652 0900
- Fax +1 508 652 0909
- Email genelec.usa@genelec.com
- In China
- Beijing Genelec Audio Co.Ltd
- Room 101, Building B33, Universal Business Park,
- No.10 Jiuxianqiao Road, Chaoyang District,
- 100015 Beijing, China
- Phone
- + 86 (10) 5823 2014
- + 86 400 700 1978
- Email genelec.china@genelec.com
- In Japan
- Genelec Japan Inc.
- 2-22-21 Akasaka, Minato-ku
- 07-0052, Tokyo
- Phone +81-3-6441-0591
genelec.japan@genelec.com Email genelec.japan@genelec.com
www.genelec.com
Genelec Document D0116R001c Copyright Genelec Oy 10. 2022. All data subject to
change without prior notice
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>