LiftMaster LM70EVFF Garage Door Opener Instruction Manual
- June 6, 2024
- LiftMaster
Table of Contents
Assembly- and operating instructions for Garage Door Opener LM70EVFF, LM70EVFFC
Note: The original installation and operating instructions were compiled
in German Any other available language is a translation of the original German
version
WARNING!
START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS!
General safety guidelines
Before you begin the installation:
Please read the operating instructions and especially the precautions
Keep the manual for future reference and pass it on to a possible subsequent
owner
The following symbols are placed in front of instructions to avoid personal
injury or property damage Read these instructions carefully
CAUTION Personal injury or property damage
CAUTION Danger due to electric current or voltage
Important safety information
The automated door opening system has been as a matter of course tested and
designed for safe operation, but safety can be assured only if the safety
instructions listed below are strictly adhered to during installation and
operation
-
The installer (specialist) must carefully read and understand these instructions before starting any work. Before first use and at least annually a specialist must inspect powered windows, doors, and gates regarding their safe condition Specialist is, who on the basis of their technical training and experience, has sufficient knowledge in the field of powered windows, doors and gates and moreover is familiar with relevant state occupational safety regulations and generally accepted rules of technology in such an extent that he is also able to assess the safe working condition of powered windows, doors and gates
-
The person installing must have knowledge of the following standards: EN 13241, EN 12604, EN 12453 The trained specialist/expert must instruct the operator in the following:
– The operation of the drive and its dangers
– The handling of the manual emergency unlocking mechanism
– The regular maintenance, inspection and care, and his tasks
– The operator must instruct other users on the operation of the drive After successful installation of the drive, the person responsible for the installation of the drive in accordance with the Machinery Directive 2006/42/EC must issue the EC declaration of conformity for the gate system The CE mark and a type plate must be attached to the gate system. This is also obligatory in the process of retrofitting on a manually operated gate Further, a handover protocol and an inspection book must be filled in. -
The door should be balanced Unmoving or stuck doors must be repaired In an unbalanced state, garage doors, door springs, cables, discs, brackets and rails are under extreme tension, which can lead to serious injury
-
Do not attempt to loosen, move or realign the door, but contact a service center or a door professional
-
During the installation or maintenance of a door opener, no jewelry, watches or loose clothing should be worn
-
To avoid serious personal injury due to entanglement, remove all cables and chains connected to the door before installing the door opener
-
During installation and electrical connection, the local building and electrical regulations must be observed
This device complies with Protection Class 2 and does not require grounding. -
To avoid damage to very light doors (such as fiberglass, aluminum or steel doors), an appropriate reinforcement should be added To do so, contact the door manufacturer.
-
The automatic safety reverse system should undergo a test Upon contact with a 50 mm high barrier on the ground, the garage door MUST return Failure to properly adjust the door opener can result in serious personal injury from a closing garage door Repeat test once a month and make any needed changes
-
This system must not be installed in damp or wet areas During operation, the gate should not under any circumstances obstruct public passageways
-
To remind all operators of the safe operation, in addition to the illuminated wall switch a warning sign to protect children should be affixed.
-
The warning signs about the risk of trapping should be placed in clearly visible spots
-
Children should be supervised to ensure that they do not play with the device
-
This device is not intended for use by persons (including children) with restricted physical, sensory or mental abilities or lack of experience and/or knowledge, unless they are supervised by a person responsible for their safety or have received instruction in how to use the device
-
All barriers/locks are deactivated to avoid damage to the door
-
If necessary, installed control equipment MUST be mounted within sight of the door and out of reach of children
-
Children should not be allowed to operate the buttons or remote controls
-
Misuse of the door opener can result in serious injury
-
The door opener should ONLY be used if the operator can see the entire door area and is assured that it is free of obstacles and the door opener is set correctly
-
No one may pass through the door while it is moving
-
Children must not be allowed to play in the vicinity of the door
-
Use the manual release only for the separation of the carriage from the drive and if possible ONLY with the door closed
-
Do not use the red handle to push the door up or pull it down
-
Before performing any repairs or removing covers, the door opener should be separated from the electric power supply
-
The repairs and electrical installations may be performed only by an authorized electrician.
-
This product has a transformer with a special power cord In case of damage this MUST be replaced with an original transformer by a qualified technician.
-
Operation of the emergency release can lead to uncontrolled movements of the door, if springs are weak or broken or if the door is unbalanced
-
Mount the release handle of the emergency release at a height less than 180 m
Save these instructions.
2 Intended use
The device is intended for the opening and closing of garage doors (please
refer to section 6 “Door Types”) The device is not meant for commercial use
but solely for the use in private garage doors that are appropriate for a
single household Any improper use of the drive could increase the risk of
accidents The manufacturer assumes no liability for such usage Only the
original accessories of LiftMaster may be connected to the drive With this
drive, automated gates must comply with the currently valid international and
country-specific standards, guidelines and regulations (among other things, EN
13241, EN 12453 and EN 12604)
3 Scope of supply
Please check the supplied parts for completeness before starting the
installation Note: The numbering only applies to the corresponding section
Parts overview:
Drive head
Remote control
Rail bracket
Hardware bag
Quick-release
Header bracket
Door bracket
Adapter for gear wheel
Curved door arm
C-bracket
Hanging bracket
Rail
MyQ Gateway and Photocells (LM70EVFFC)| 1x
2x
2x
1x
1x
1x
1x
1x
1x
2x
2x
1x
1x
---|---
Hardwarebag:
Truss head screws 6 x 80 mm
Lock nut M6
Hexagonal head screw
Nut M6
Bolt
Safety cotter pin
Screw ST 6 x 50 mm
Screw ST 6,3 x 18 mm
Plug| 1x
1x
4x
4x
1x
1x
4x
8x
4x
---|---
Product overview
This figure always offers you a complete overview of the ready-assembled
system during the step by step installation of the system begin
Header bracket
Belt
Rail
Carriage
Connecting piece
Rail bracket
Hanging bracket| Power cable
Drive head
Release
Straight door arm
Curved door arm
Door bracket
---|---
Before you begin
IMPORTANT NOTE If your garage does not have a side entrance, an external
emergency release should be installed This allows for manual operation of the
garage door from the outside during power failure
Door Types
A One-Piece Door with Horizontal Track Only
B One-Piece Door with Horizontal and Vertical Track Special door arm (E, The
Chamberlain ArmTM) and the Protector SystemTM required See your dealer
C Sectional Door with Curved Track See 20B connect door arm
D Canopy door Special door arm (E, The Chamberlain ArmTM) and the Protector
SystemTM required to See your dealer
E The Chamberlain ArmTM for use on door types B and D
Preparation
First, check whether your door is balanced and in equilibrium Open your door
about halfway and let it go The door can now hardly change its position
independently, but must remain in this position held by the spring force alone
- The rail of the garage door MUST be connected securely and firmly to the supporting wall or ceiling above the garage door
- Additional brackets and mounting rails (not included in the supply) might be required, if the your garage ceiling has a cladding, boards or similar
- If your garage does not have a separate side entrance, an external emergency release (refer to section 34 “Optional Accessories”) must be installed
Tools required
Tool list:
Ladder
Marking pen
Pliers
Drilling machine
Hammer
Ratchet 10 mm / 13 mm| Hacksaw
Different drill bits for concrete
and(or wood (8, 6, 5, 4 .5 mm)
Box wrench
Water level
Screwdriver
Measuring tape
---|---
Assembling the rail
Important instructions for a safe installation. Observe all assembly
instructions. Incorrect installation can cause serious injury.
The rail is largely preassembled and consists of 3 parts The carriage,
pushrod, release handle, the guide pulley and the lintel bracket with belt
tensioner are in the front part (A) The seating for the driveshaft and the
sprocket are in the rear part (B) Lay the front and rear rail sections one
behind the other
- Remove cable ties that secure the belt
- Pull apart the two rail sections completely in order to create a gap for the middle section (C) This rail is designed in such a way so as to easily add the middle section Slide the 2 connecting pieces (D) over the seams of the rail sections up to the markings To secure the connecting pieces, bend the sheet metal lugs outwards with a suitable tool
The assembly of the rail is complete
Tighten the belt
Tighten the belt of the rail until the spring (1) is compressed only by about
half The spring must compress and be able to bounce during operation
Fitting rail to the drive
- Check if the belt is seated on the gear wheel If the belt has slipped off during assembly, relax the belt, lay it, and tighten again.
- Turn around the rail (1) and completely put on the opener (3) with the gear side (2)
- Secure the rail on the opener with two mounting brackets (10) and the screws (21)
Optional : To reduce the total overall length by 140 mm the drive can be
rotated by 90° as shown in fig.11. This allows access and programming
sideways. Unscrew the switch and mount it to the designated second position
Remove the rubber plug in order to seal the cable exit Proceed with step 3 The
change must be made by an authorized electrician
Centre of the garage door
Eye protection goggles should be worn for overhead work All available
barriers/locks should be deactivated to avoid damage to the door To avoid
serious injuries, remove all cables and chains connected to the door before
installing the door opener The door opener should be mounted at a height of at
least 210 m above the ground First, mark the centerline of the door (1) Draw a
line to the ceiling starting from this point For installation on the ceiling,
draw another line to the centre of the ceiling (2) perpendicular to the door
starting from this line Length approx 280 m
Mounting header bracket
Note: Mount the rail max 50mm above the top edge of the door depending on
the door type, the top edge of the door is lifted by a few cm during opening
A. Wall fastening: Mount header bracket (7) centrally on the vertical
centerline (2); thereby its lower edge lies on the horizontal line Mark all
holes for the header bracket Pre-drill holes with 45 mm diameter and fastens
the header bracket with wood screws (20) Note: In case of mounting on a
concrete slab / concrete header, the provided concrete plugs (22) and screws
(20) should be used Drill hole size in concrete: 8 mm.
B. Ceiling suspension : Draw a vertical centerline (2) further up to the
ceiling and about 200 mm along the ceiling Attach header bracket (6) centrally
on the vertical marking up to 150 mm removed from the wall Mark all holes for
the header bracket Drill holes with 45 mm diameter and fasten the header
bracket with wood screws (20)
Attaching drive to the header
It may be necessary to place the drive temporarily higher so that the rail
does not hit the springs in sectional doors The drive must either be well
supported (ladder) or held firmly by a second person. Put drive head-on the
garage floor under the lintel bracket. Lift rail up till the holes of the
fixing part and the holes of the lintel bracket are aligned Insert screw (14)
through the holes and secure with nut (15).
Hang opener
Fully open the door, put down door opener on the door (Fig A) Lay a piece of
wood/cardboard on the marked spot (X)
The opener must be securely fastened to a structural support of the garage
Three representative installations are shown (Fig B) Yours may be different.
Hanging brackets (11) should be angled to provide rigid support. On finished
ceilings, attach support bracket(not delivered) to a self-supporting
structure-nal element before installing the opener For a concrete ceiling
mount, use concrete anchors (22) provided On each side of the opener measure
the distance from the opener to the structural support (or ceiling) Cut both
pieces of the hanging bracket to required lengths. Flatten one end of each
bracket and bend or twist to fit the fastening angles Do not bend at the
bracket holes Drill 4,5mm pilot holes in the structural supports (or ceiling)
Attach brackets to supports with wood screws (20).
Lift opener and fasten to hanging brackets with screw (16) and nut (17) Check
to make sure rail is centered over the door Remove piece of wood/cardboard
Operate the door manually If the door hits the rail, raise header bracket.
After the installation of the garage door drive, particularly using a rail
extension, if the rail is observed to be bent up or down for more than 5 cm
during the beginning or end of the travel as well as while encountering an
obstacle, a central suspension must be provided by the customer For this,
please contact the manufacturer of the garage door drive
Pay attention to a horizontal course of the rail along the ceiling distance
can be adjusted by the given hole spacing. Protruding ends of the ceiling
fixture can be reduced if necessary.
Mounting door bracket
Installation in sectional or one-piece doors: The door bracket (7) has
multiple mounting holes Attach door bracket top centre on the inside of the
door as shown Mark holes and screw door bracket 1 One-piece or sectional door
with a guide rail: distance to door top edge 0-100 mm
2 Sectional door with two guide rails: distance to door top edge 100-130 mm
NOTE: The attachment point on the door must be the frame or a stable
place on the door panel If necessary, drill through and screw (not included)
together as shown in Fig B.
Attaching door arm on the trolley
The straight door arm is already pre-assembled. Pulling the red handle the
trolley will be released and can be moved manually DISCONNECT THE TROLLEY: 1
The door should be fully closed if possible 2 Pull down on the emergency
release handle RECONNECT THE TROLLEY: The lockout feature prevents the trolley
from reconnecting automatically Push the green button on the trolley With the
next-door movement the system will reconnect.
** Mount the release handle of the emergency release at a height of at
least 180 m Attach the yellow label regarding the release of the garage door
opener (sticker) on the cord of the door handle.
Electrical connection
** In order to avoid personal injury and damage to the device, the door
opener should be operated only if such an instruction is explicitly stated in
this manual The power plug must always be accessible for the purpose of
disconnecting the mains supply Electrical installations may only be undertaken
by an authorized electrician
Install illuminated push button or Multi-function door control (optional
accessory).
Locate door control where the garage door is visible, away from door and door
hardware and out of the reach of children Mount at least 1,5 m (5 feet) above
the floor. Permanently fasten the caution label permanently to the wall near
the door control as a reminder of safe operating procedures There are 2
terminals on the back of the door control Strip about 6mm of insulation from
bell wire Separate wires enough to connect the white/red wire to RED terminal
screw and the white wire to WHT terminal screw Fasten the door control to an
inside garage wall with sheet metal screws provided Drill 4mm holes and use
anchors if installing into drywall A convenient place is beside the service
door and out of reach of children Run the bell wire up the wall and across the
ceiling to the garage door opener Use insulated staples to secure wire.
Operation of the Door Control: Press to open or close the door Press again to
stop the door while moving
Installation of photocells (Optional accessory).
After installing and adjusting the door opener, photocells can be installed
The instructions for installation are included in the scope of delivery of the
light barrier and must be followed The optional photocells ensure that the
door is open, or remains open, if people, especially young children, are in
the door area. By means of the photocells, a closing door is opened or an open
door is obstructed from closing if a person located in the door area
interrupts the sensor beam.
Photocells are particularly recommended for families with young children.
Connecting the opener
Connect the opener in accordance with local rules and regulations to a
properly installed wall socket NOTE: When the opener is switched on, the
operator light is also turned on for 25 minutes.
Program opener and test
** The door opener should only be used if the operator can see the entire
door area and is assured that it is free of obstacles and the door opener is
set correctly No one may pass through the door while it is moving. Before the
first opening operation, check that all the facilities that are not needed are
turned off. Remove all mounting aids and tools from the pivot area of the
door.
Setting the Limits
Travel limits regulate the points at which the door will stop when moving up
or down Follow the steps below to set the limits This operator is equipped
with a two speed system that is automatically set by the software Canopy or
1-piece garage doors will automatically run in slow speed to insure a safe
operation according regulatory Doors traveling shorter than 190 cm will run
automatically slow.
INTRODUCTION:
Your garage door opener is designed with electronic controls to make setup and
adjustments easy The adjustments allow you to program where the door will stop
in the open (UP) and close (DOWN) position The electronic controls sense the
amount of force required to open and close the door The force is adjusted
automatically when you program the travel.
NOTE: If anything interferes with the door’s upward travel it will stop
If anything interferes with the door’s downward travel, it will reverse To
watch a short instructional video on programming your new garage door opener
use your smartphone to read the Code on this manual backside or visit
www.chamberlain.eu
PROGRAMMING BUTTONS:**
The programming buttons are located under a removable cover on the backside of
the garage door opener (see fig24).
- Press and hold the square Adjustment Button until the UP Button begins to flash.
- Press and hold the UP Button until the door is in the desired UP position NOTE: The UP and DOWN buttons can be used to move the door up and down as needed
- Once the door is in the desired UP position press and release the Adjustment Button. The garage door opener lights will flash and the DOWN Button will begin to flash.
- Press and hold the DOWN Button until the door is in the desired DOWN position Make sure the rail does not bend NOTE: The UP and DOWN Buttons can be used to move the door up and down as needed.
- Once the door is in the desired DOWN position press and releases the Adjustment Button. The garage door opener lights will flash and the UP Button will begin to flash.
- Press and release the UP Button When the door travels to the programmed UP position, the DOWN Button will begin to flash. Note: IF the door does not travel to the UP position the travel limit programming failed Begin again with step1 If door travel is too short please refer to section 33 “Frequently Asked Questions”.
- Press and release the DOWN Button The door will travel to the programmed DOWN position Programming is complete.
Test the Safety Reverse System.
The safety reverse system test is important. A garage door must reverse
on contact with a 50 mm obstacle laid flat on the floor. Failure to properly
adjust the opener may result in serious personal injury from a closing garage
door. Repeat test once a month and adjust as needed.
OBSTACLE TEST:
Place a 50 mm high obstacle (1) under the garage door on the floor. Move door
downwards The door must reverse when it comes into contact with the obstacle
If upon contact the door stops, the door does not move down far enough In this
case repeat limit setting If the door reverses after contact with the 50 mm
high obstacle, remove obstacles and open and close the door completely once
The door should not go back if it reaches the door position,, Closed” If it
still reverses both limits must be reprogrammed.
OPENING TEST:
Apply 20 kg to the middle of the door The door should not open completely.
25 Program your opener and remote / the Wireless push button (optional)
Activate the opener only when door is in full view, free of obstruction and
properly adjusted. No one should enter or leave the garage while the door is
in motion. Do not allow children to operate push button(s) or remote(s). Do
not allow children to play near the door.
Your garage door opener receiver and one of the buttons remote control are
pre-programmed If you purchase additional remote controls, the garage door
opener must be programmed to accept the new remote code
Program the Receiver to Match Additional Remote Controls: Using the yellow
round button.
- Press and release the yellow round button on the opener The learn indicator light will glow steadily for 30 seconds (1).
- Within 30 seconds, press and hold the button on the hand-held remote that you wish to operate your garage door (2).
- Release the button when the opener light blinks once It has learned the code Now the opener will operate when the remote control push button is pressed If you release the remote control push button before the opener light flashes, the opener has not learned the code.
To Erase all Remote Control Codes.
To deactivate any unwanted remote, first erase all codes: Press and hold the
yellow round button on opener until the learn indicator light goes out
(approximately 10 seconds) All previous codes are now erased Reprogram each
remote or keyless entry you wish to use.
Connect the LiftMaster Internet Gateway
(incl. LM70EVFFC, optional LM70EVFF)
Before starting you MUST have:
- a router
- active internet connection
- a free “Ethernet” terminal on your router
- internet gateway serial number (on the backside of the device)
- a pair of photocells connected to the garage door opener If there are no photocells connected the garage door can only be opened.
WARNING!
To prevent possible SERIOUS INJURY or DEATH: · When the LiftMaster Internet
Gateway is used with a garage door the opener, the opener MUST ONLY be
installed with sectional doors
- Never allow children to play with the garage door, the remote control, wall switches or any other accessories.
- Operate the garage door only when it is technically faultless and the donor area is free of obstructions or people.
- This product allows operating the garage door without visual control.
- Therefore the door may execute unexpected travels Never pass through a closing garage door.
- For residential use only Only instructed people may use this.
- product.
- Some parts of the car (doors, trunk lids) may extend into the travel path and cause serious damage to the garage door and/or the car .
- The serial number on the backside of this device is for your personal use only Save this number from others.
-
Connect
Connect the provided ethernet cable (1) to the router (2) Use the plug valid for your country ( not all models) Connect power (3) to the internet gateway (4) When the internet gateway connects to the internet, the green light (5) will stop blinking and will light solid -
Create an account
Visit liftmastereu and follow the steps to create an account on this website If you already have an account, use your username and password -
Register the internet gateway
Enter the Serial Number located on the bottom of the internet gateway when prompted -
Add MyQ devices
Use an internet-enabled computer or smartphone to add devices Follow the instructions on the website/app Note: After you add a device, the blue light on the internet gateway will appear and stay on For smartphones/tablets free apps can be downloaded from iTunes Store or Google Play Computers: You are able to operate your garage door using your internet browser -
Test
After having installed and registered correctly you may now test the following features: · open and close the garage door · status request DOOR OPEN or DOOR CLOSED.
Need Help?
Visit my Liftmaster euor send us an e-mail with
info.@liftmaster.eu
Special Features (optional)
A. Door within a door connection
Locate auxiliary quick-connect terminals Remove wire bridge Insert bell wire
into quick-connect terminals 4 and 5.
B. Flashing light connection
Description of feature:
The Chamberlain flashing light can be installed anywhere. Connect light
leads to quick-connect terminals 6 and 7.
C. Partial opening feature
Description of feature:
The pedestrian, ventilation or pet opening position is an adjustable second
stop position between the fully opened and fully closed position of the garage
door Activate:
NOTE: Any time programming requires pushing two buttons simultaneously,
make sure this is executed accurately If other buttons than described will
flash, briefly cut operator from current and start programming from the
beginning.
- Move the door into to the desired partial opening position using the remote control or wall control.
- Choose a nonprogrammed button on your remote control 3 Push square button and UP button simultaneously for 3 seconds and wait for the operator light to flash. Then push the remote control button To program an additional remote control start again with step1.
Deactivate: 1 Move the door to the fully closed position 2 Push square button and UP button simultaneously for 3 seconds and wait for the operator light to flash.
D. Instructions for Auto-Close
Feature Description of feature :
The Chamberlain Safety IR Sensors must be installed (required by
EN60335-2-95).
Activate: Push square and DOWN button simultaneously until the operator light
blinks 1 push UP button = 10 seconds up to 180 sec possible (18x) During the
countdown the down button flashes. To complete programming push the square
button.
Deactivate:
Push square and DOWN button simultaneously until the operator light blinks To
complete programming push square button Notes: – The auto-close timer resets
if the IR sensors are interrupted – In the partially open position automatic
close is not possible – The garage door operator must have reached the
programmed UP limit to activate the auto-close timer.
Troubleshooting:
Question: Operator will not work anymore without IR sensor Solution: Correct
IR sensors are mandatory once connected A full logic board reset is required
E. Change from fast speed to slow speed
Description of feature:
The garage door opener chooses the necessary speed automatically Change speed:
1 Move the door to the fully closed position 2 Push UP and DOWN buttons
simultaneously until operator light blinks Attention: One-piece doors, Canopy
garage doors and any other type of swing-out doors must be operated with slow
speed For safety reasons, below 19m of travel length the speed is slow
F. OPEN, STOP, or CLOSE programming of the remote control.
Description of feature:
Each remote control button can be programmed to either
OPEN, STOP or CLOSE the door
OPEN:
Push the yellow round button and UP button simultaneously until the LED goes
on Now push a selected button on the remote control for OPEN only and wait for
the operator light to flash.
STOP:
Push the yellow round button and square button simultaneously until the LED
goes on Now push another selected button on the remote control for STOP only
and wait for the operator light to flash.
CLOSE:
Push the yellow round button and DOWN button simultaneously until the LED goes
on now push the third button on the remote control for CLOSE only and wait for
the operator light to flash.
G. Holiday Mode (requires 78EV wall control):
Portable remote controls do not function if this feature is activated
H. Program remote control via wall control
(requires 78EV wall control)
I. Operator light control (requires 78EV wall control):
The operator light can be switched on and off at any time. Automatic lighting
(only with light barrier and wall bracket) When the light barrier is
interrupted, the lighting automatically switches on during the opening of the
door Activation: Press and hold the “LIGHT” button on the wall bracket for 10
seconds Deactivation: see activation
J. Keyless entry (requires 747EV wireless keypad) :
Enter a 4 digit code of your choice to operate the door
K. Temporary access (requires 747EV wireless keypad):
A temporary code can be programmed to allow limited access to the garage (by
time or number of openings)
L. One button close feature (requires 747EV wireless keypad) :
Without having the access code the door can be closed from any position (not
opened)
M. MyQ (requires 828EV gateway):
Allows operating your garage door opener via the internet or a compatible
mobile phone
N. Garage Door Monitoring (requires 829EV Garage Door Monitor):
Features optical (by LEDs) and audible control of the status of your garage
door Allows closing your garage door from the place this device is installed
O. Power supply for external devices (terminal 30V)
30VDC/max 50mA Note: For external (universal) receivers, the under 1-watt
standby mode must be turned off.
P. Turning on/off the under 1-watt standby mode
The under 1W standby mode is always switched on at the factory.
(After the lights go off and with the garage door closed.)
Switch off under 1-watt standby:
- Disconnect devise from the mains.
- Press the UP and DOWN buttons on the back on the adjusting panel simultaneously and hold.
- Connect the device again while the buttons are still pressed.
- After about 5 seconds the opener’s light flashes 10 times as confirmation.
Note: Every time the opener is disconnected from the mains, the opener’s
light flashes 10 times during reconnection to indicate that the under 1-watt
standby mode is off. Switch on under 1 watt standby: See activation
Q. Cycle counter This garage door opener features a cycle counter
(open/close = 1 cycle)
- Pull plug
- Simultaneously press and hold round and square buttons on the backside of the opener
- While holding the buttons insert the plug
- After approx
- sec the LED indicates the number of cycles (for every 100 cycles the LED flashes once). Release buttons.
28 Operation of the door opener
Automatic opening/closing of the door: The door opener can be operated using
the following devices:
Remote control: Press the button until the door starts to move ·
Wall switch (if this accessory is installed): Press the pushbutton until
the door starts to move
Manual opening of the door (by hand):
If possible, the door must be closed completely Weak or defective springs
can cause a rapid shutting down of the open door, which can lead to property
damage or serious personal injury.
RELEASE: Briefly pull the red handle down. Then open the door by hand
Open close door without pulling the cable!
RECONNECT: The lockout feature prevents the trolley from reconnecting
automatically Push the green button on the trolley With the next-door movement
the system will reconnect.
Function sequence: When operating the door opener by radio control or
wall switch:
- closes the door when it is fully open
- opens the door when it is fully closed
- stops the door if it is opening or closing
- the door moves in the opposite direction to the last completed move,if it is partially open
- drives back the door to the open door position, if it hits an obstruction while closing
- stops the door, if it encounters an obstacle during opening
- Photocells (optional): By means of the photocells, a closing door is lifted up or an open door is obstructed while closing if a person located in the door area interrupts the beam
- THE MULTI-FUNCTION DOOR CONTROL (optional) Press the push bar (1) to open or close the door Press again to stop the door Light feature Press the Light button (2) to turn the opener light on or off. It will not control the opener light when the door is in motion If you turn it on and then activate the opener, the light will remain on for 2-1/2 minutes. Press again to turn it off sooner.
The operator light switches on in the following cases:
- First turning on of the door opener (short).
- Power interruption (short).
- With each turning on of the door opener, The light turns off automatically after 2 1/2 minutes.
Attach warning labels (see fig. 28)
Cleaning and maintenance
Before any maintenance, cleaning, and related maintenance work, the main
supply plug should be pulled out. Danger from electric shock!
Maintenance of the door opener A proper installation ensures the optimum
performance of the door opener with minimum maintenance An additional
lubrication is not required Gross dirt accumulation in the guide rail may
impair the function and must be removed.
Cleaning
Clean the drive head, wall switch and remote control with a soft, dry cloth Do
not use liquids.
Maintenance
Check the system often, especially cables, springs, and fasteners, for signs
of wear, damage or lack of balance Do not use if repair or adjustment work
must be performed, because an error in the system or an incorrectly balanced
door may cause injury Repairs to electrical equipment and gates may be carried
out only by an authorized specialist/expert In any case, please do not ever
carry out repairs yourselves because this could result in serious injury or
death
Once a month:
- Check automatic safety reverse again and reset if necessary
- Operate the door manually If the door is unbalanced or stuck, please contact the service center
- Check for complete opening and closing of the door Where appropriate, readjust limit switches and/or power
Twice a year:
- Check the belt tension. For this, first disconnect the carriage from the drive If necessary, adjust belt tension.
Once a year (at the door):
- Lubricate door roller, bearings and joints An additional lubrication of the door opener is not required.
Limit switch adjustment and force regulation: These settings must be
checked and undertaken properly during the installation of the opener Due to
weathering, minor changes can occur during the operation of the opener that
needs to be addressed by a new setting. This can particularly happen in the
first year of operation. Follow the instructions for setting travel limits and
force (refer to sections 23 and 33) carefully and re-check the automatic
safety reverse after each resetting
Replace batteries of the remote control
A battery of the remote control:
The batteries in the remote have an extremely long life If the transmission
range decreases, the batteries must be replaced Batteries are not covered by
the guarantee.
Please observe the following instructions for the battery:
Batteries should not be treated as household waste All consumers are required
by law to dispose of batteries properly at the designated collection points
Never recharge batteries that are not meant to be recharged.
Danger of explosion!
Keep batteries away from children, do not short-circuit them or take them
apart See a doctor immediately, if a battery is swallowed If necessary, clean
contacts on battery and devices before loading Remove exhausted batteries from
the device immediately!
Increased risk of leakage!
Never expose batteries to excessive heat such as sunshine, fire or the like!
There is an increased risk of leakage! Never expose batteries to excessive
heat such as sunshine, fire or the like! There is an increased risk of
leakage! Avoid contact with skin, eyes and mucous membranes Rinse the parts
affected by battery acid with plenty of cold water and consult a doctor
immediately Use only batteries of the same type Remove the batteries if the
device is not being used for a long time.
Replacing battery:
To replace the battery, turn the remote control around and open the case with
a screwdriver Lift cover and lift the control board below Slide battery to one
side and remove the Watch polarity of the battery! Assemble again from in
reverse direction.
ATTENTION!
The danger of explosion if the battery is replaced improperly Replacement only
by identical or equivalent type (CR2032).
Operator light
The LED lighting has a very long life and is maintenance-free The lens cover
cannot be removed.
Disposal
The packaging must be disposed of in the local recyclable containers According
to the European Directive 2002/96/EC on waste electrical equipment, this
device must be properly disposed of, after usage in order to ensure recycling
of the materials used.
Old accumulators and batteries may not be disposed of in the household waste,
since they contain pollutants and must be properly disposed of in municipal
collection points or in the containers of the dealer provided. Country-
specific regulations must be observed The components must be properly disposed
of at a public company specializing in waste disposal. The relevant local and
country-specific regulations must adhere to All decommissioned drive
components may not be disposed of in the household waste.
The competent authority (city, town) or its disposal company will inform you
about the possibilities of this disposal.
Frequently asked questions
1. Door opener doesn’t work with remote control:
- Is the opener connected to the power supply? If a lamp connected to the power socket does not turn on, check the fuse or circuit breaker (Some sockets are enabled via a wall switch)
- Are all door locks disabled? See safety instructions!
- Check if the remote control battery is lit
- If you have two or more remote controls, of which only one works, check the programming of the receiver
- Is there snow/ice under the door? If yes, the door may be frozen onto the ground Remove all obstacles
- Perhaps the door spring is defective This must be replaced by a specialist
2. Transmission range of the device is too low:
- Is a battery inserted? Put in a new battery.
- Try radio control in the car at another location.
- The transmission range diminishes for metal doors, aluminum or metal panels.
3. Door reverses for no apparent reason:
- Is the door blocked by anything? Pull manual release and operate door by hand In case of the unbalanced or stuck gate, please contact the service department
- Re-program operating force
- Clear ice or snow in the closing area of the door
- If the door reverses upon reaching the door position `Closed’, the limit switch must be set for this door position After completing every setting, the automatic safety reverse must be checked again:
- An occasional resetting of the end positions is not unusual In particular, the weathering can shift the doorway
4. The garage door opens and closes by itself:
- Delete all remote controls and then re-program them See section 25
- Is the remote control button jammed in position,, ON”?
- Use only original remote controls! The use of third-party products leads to disturbances
- The remote control button was pressed accidentally (pocket)
- The cable of the wall switch is damaged (remove for testing purposes)
- An accessory connected to the opener causes the drive (remove for testing purposes)
5. Door does not close completely:
- The re-program stretch of the way of the opener Check for alterations in the mechanical components, e.g. door arms and fittings.
After each new set of the door position `Closed’, the automatic safety reverse should be checked for function.
6. The door opens, but does not close:
- If installed, the photocells should be checked If the LED at the photocells blink, the alignment should be checked .
- Check remote control or wall switch for function.
7. Operator light doesn’t turn on:
- Open or close the door The light remains switched on for 25 minutes.
- Disconnect the opener from the mains and connect again The light comes on for a few seconds .
- No power
8. Operator light doesn’t turn off:
- Disconnect the power from the main supply for a short time and try again.
- The 25 minutes are not yet over.
9 . Motor hums and runs very briefly, but does not function:
- Garage door springs are defective Close the door and disconnect from the opener by pulling on the handle of the carriage (manual release) Open and close door manually.
- If the door is properly balanced, it is held at each point of the doorway by the door springs alone If this is not the case, contact your service centre · If this problem appears during the first use, the door may be locked. Deactivate door lock
- Release opener from the door and try without a door. If the door is fine, reprogramme the operating force and stretch of the way.
10. Opener works only in one direction:
- The door springs may be defective or the door is stiff in one direction.
- If the door is fine, re-program operating power and stretch of way of the opener.
11. The belt rattles on the rail:
- Adjust the belt tension The cause is usually a very tight chain/belt The spring on the clamping device of the rail must not be compressed completely.
- The door runs unevenly and makes the drive vibrate Improve the door run.
12. Opener will not start due to power failure:
- Disconnect from the opener by pulling on the handle on the carriage (manual release) The door can now be manually opened and closed If the opener is re-activated, the carriage also gets re-connected
- If installed, the carriage is detached from the drive in case of a power failure by an external emergency release from outside the garage.
13. Door reverses after the force was programmed:
- See if the rail bends The opener requires a lot of power to move the door Repair or install the door correctly
- The door is very heavy or in poor condition Call a specialist
14. Rail bends on the opener:
- The door is heavy, very heavy, stiff or in poor condition. Call a specialist.
- A swing of the rail while moving is a sign of an unevenly functioning door with constantly changing power requirements Call specialist, possibly lubricate door An additional suspension on the rail can be a remedy
14. Rail bends on the opener:
- The door is heavy, very heavy, stiff, or in poor condition. Call a specialist.
- A swing of the rail while moving is a sign of an unevenly functioning door with constantly changing power requirements Call specialist, possibly lubricate door An additional suspension on the rail can be a remedy.
15. The opener,, runs” (audible turning of the motor) but the carriage does not move:
- The carriage is released from the opener
- In a new installation: During the assembly of motor and rail, the pre-assembled adapter sleeve between the motor shaft and the rail was not installed This sleeve is pre-assembled at the factory, but can be removed Standing behind the opener it can be observed whether the gearwheel turns in the rail or just the motor
- In a new installation: The belt has come off from the gearwheel in the rail Standing behind the opener, you can see the gearwheel
- After years of use: Is the release defective or continuously disengaged?
- After years of use: The sleeve between rail and motor or the motor control gear is defective.
16. The door releases by itself from the carriage and stops:
- An external release that has been installed during a power failure should be checked whether it stretches and releases during the opening of the door Watch the mechanism and reset if necessary
- The handle of the release mechanism should not get caught in other items.
17. Setting the Force
- The force setting button is located behind the cover at the operator’s backside The force setting regulates the amount of power required to open and close the door.
1 Open cover on the backside of the opener Locates the yellow round button (2).
2 Push the yellow round button (2) twice to enter the unit into Force Adjustment Mode The LED (3) (indicator light) and the UP button will flash. Push UP button. The operator will travel to the UP position learning the required amount of force Once the UP limit is reached the LED and the DOWN button start to flash. Push the DOWN button. The operator will travel to the DOWN position learning the required amount of force.
Diagnostic Chart
Your garage door opener is programmed with self-diagnostic capabilities The UP
and DOWN arrows on the garage opener flash the diagnostic codes.
DIAGNOSTIC CODE| Up Arrow Flash(es)
Down Arrow Flash(es)| SYMPTOM| SOLUTION
---|---|---|---
1| 1| The garage door opener will not
close and the light bulbs flash.| Safety sensors are not installed, connected
or wires may be cut. Inspect sensor wires for a disconnected or cut wire.
---|---|---|---
1| 2| The garage door opener will not
close and the light bulbs flash.| There is a short or reversed wire for the
safety sensors. Inspect safety sensor wire at all staple points and connection
points and replace wire or correct as needed.
1| 3| The door control will not function| The wires for the door control are
shorted or the door control is faulty. Inspect safety sensor wire at all
staple points and connection points and replace wire or correct as needed.
1| 4| The garage door opener will not
close and the light| Safety sensors are misaligned or were momentarily
obstructed. Realign both sensors to ensure both LEDs are steady and not
flickering. Make sure nothing is hanging or mounted on the door that would
interrupt the sensor’s path while closing.
1| 5| The door moves 6-8“ stops or reverses| Manually open and close the door.
Check for binding or obstructions, such as a broken spring or door lock,
correct as needed. Check wiring connections at the travel module and at the
logic board. Replace the travel module if necessary.
1| 5| No movement, only a single click| Manually open and close the door.
Check for binding or obstructions, such as a
broken spring or door lock, correct as needed. Replace the logic board if
necessary.
1| 5| Opener hums for 1-2 seconds no
movement| Manually open and close the door. Check for binding or obstructions,
such as a
broken spring or door lock, correct as needed. Replace motor if necessary.
1| 6| Door coast after it has come to a
complete stop| Program travel to coasting position or have door balanced by a
trained technician.
2| 1-5| No movement or sound| Replace logic board.
3| 2| Unable to set the travel or retain the position| Please refer to section
33 “Frequently Asked Questions”, chapter 15.
4| 1-4| Door is moving stops and or reverses| Manually open and close the door
Check for binding or obstructions, such as a broken spring or door lock,
correct as needed. If the door is binding or sticking contact a trained door
systems technician. If the door is not binding or sticking attempt to
reprogram travel (refer to page 24 ).
4| 5| The opener runs approximately 6-8“,
stops and reverses| Please refer to section 33 “Frequently Asked Questions”,
chapter 15.
4| 8| The garage door opener will not
close and the light bulbs flash.| Safety sensors are misaligned or were
momentarily obstructed. Realign both sensors to ensure both LEDs are steady
and not flickering. Make sure nothing is hanging or mounted on the door that
would interrupt the sensor‘s path while closing.
5| 1| Terminal 1+2 for wall control is shortened longer than 4 seconds| Check
wiring for push-button if the button is stuck and activated permanently.
Remove wiring from terminal 1+2 on the operator as a test. Do not run push
button wires next to high voltage wiring or in the same conduit.
5| 5| Low voltage| The operator has been shut off due to the lower voltage
supplied than allowed. If an external backup battery pack is installed, check
if empty. If mains supply is used, check wiring and supply.
6| 1| Maximum radio memory has been
reached| Maximum capacity for storage of remote controls has been reached. The
first remote control or more previously programmed remote controls’ codes have
been replaced by a new one, To reset diagnostic remove power from the
operator.
Optional Accessories
Always use LiftMaster accessories
External products can cause malfunctions
1 | TX4UNIF | 4-channel universal remote control |
---|---|---|
2 | TX4EVS | 4-channel remote control |
3 | TX4UNI/S | 4-channel universal remote control |
4 | 128EV | Wireless Wall Control 2-Channel |
5 | 747EV | Keypad |
6 | 828EV | MyQ Gateway |
7 | 829EV | Garage Door Monitor |
8 | EQL01EV | Quick-release |
9 | 1702EV | Quick-release |
10 | 75EV | Wired push button |
11 | 78EV | Wired multi-functional wall control |
12 | FLA-1LED | Flashing light |
13 | G770E | Photocells |
14 | 771EV | Photocells |
15 | 772EV | Photocells |
16 | 100034 | Key switch (flush mount) |
17 | 100041 | Key switch (surface mount) |
18 | 16200LM | Door in Door contact |
Door dimensions und -weight
One-piece doors
| LM70EVFF|
LM70EVFFC
---|---|---
max-width (mm)| 5000| 5000
max height (mm)| 2500| 2500
max weight (kg)| 110| 110
Sectional doors
| LM70EVFF|
LM70EVFFC
---|---|---
max-width (mm)| 5000| 5000
max height (mm)| 2500| 2500
max weight (kg)| 110| 110
Service parts / Warranty
Your statutory rights are not affected by this manufacturer‘s warranty.
Please see www. Liftmaster.EU for terms of the
warranty.
Specifications
Input Voltage | 220-240 VAC, 50/60 Hz |
---|---|
Max Pull Force | 700 N |
Standby Power (door fully closed) | 08 W |
Motor type | DC Gearmotor permanent lubrication |
Noise level | 54dB |
Drive Mechanism | Belt |
Length of Travel | 2682 mm |
Opening speed, up to | 160 mm/s |
Mazdoor weight | 110 kg |
Mazdoor dimensions, height / width | 250 / 500 m |
Lamp | On when the door starts, off 2-1/2minutes after stop |
Door Linkage | Adjustable door armful cord trolley release |
Safety, Personal | Push-button and automatic stop in down direction Push button |
and automatic stop in the up direction
Electronic| Automatic force adjustment
Electrical| Transformer overload pro- tector and low voltage push button
wiring
Limit Device| Mechanical RPM/Passpoint detector
Limit Adjustment| Electronic
Soft-Start / Soft-Stop| all model
Length (Overall)| 3367 mm
Headroom Required| min 35 mm
Hanging Weight| ~ 12 kg
Memory Registers| 180
Operating Frequency:| 7-Band (433 MHz / 868 MHz)
Max power of the remote control| < 5 mW
Declaration of conformity
The manual consists of these operating instructions and the declaration of
conformity.
http://www.liftmaster.eu
Chamberlain GmbH
Alfred-Nobel-Strasse 4 66793 Saarwellingen
Germany WEEE-RegNr DE66256568
www.Liftmaster.eu
info@liftmaster.eu
2018, all rights reserved
Read User Manual Online (PDF format)