PL-1048-4-BBZ Low Voltage Landscape Lighting
Important: Please Read Before Installation
This luminaire is intended for installation in accordance with local codes and
the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
- Make sure that the power is turned OFF before installing or servicing this fixture.
- Warning: this fixture is not intended to be installed within 10 feet [3 meters] of a pool, spa or fountain.
- This fixture is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
- Underground Low Energy Cable must not be buried over 6” (15.2 cm) in order to connect to the main low voltage cable.
- Wiring connections must be made with UL Listed wire connectors that are suitable for the application.
- Position the wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire, or fitting.
Important Safety Instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
WARNING: To reduce the risk of FIRE OR INJURY TO PERSONS.
- Turn off/unplug and allow to cool before reducing the lamp.
- The lamp gets HOT quickly!
- Do not touch the hot lens, guard, or cowl.
- Keep the lamp away from materials that may burn.
- Do not touch the lamp at any time.
- Use a soft cloth.
- Oil from the skin may damage lamp.
- Do not operate the fixture with a damaged or missing lens or shield.
Package Contents
A. Fixture Body
Parts Required
A. Mounting Accessory
B. GU4 Bi-Pin
Product Dimensions
Installation Instructions
Remove Lens
Install Bulb
Install Lens
Install Stake
Install Fixture Body to Stake
Pass the supply wires through the center hole of the stake and thread the stem onto the stake. Hand tightens until snug. Clear away an area in the ground and lay the supply wires into the wireway slot.
Wire Connections
Main Supply Cable
Strip both leads from the fixture wires. Using two UL listed wire connectors
(sold separately), connect the leads from the fixture wires to the main supply
cable leads.
Adjust Shade Direction
There are two methods to adjust the shade direction.
NOTE: Do not rotate the shade a full 3600. This will damage the internal
wiring.
- A. Loosen the knuckle on the stem to adjust the shade to your desired angle. Once your desired angle is achieved, hand tighten the knuckle to secure the shade direction.
- B. Using the Allen wrench, loosen the set screw on the stem and adjust the shade to your desired angle. Once your desired angle is achieved, tighten the set screw using the Allen wrench to secure the shade direction.
Install/Replace Bulb
Reverse Step 2 – Step 3 to expose the bulb and replace it with the correct
wattage and type marked on the fixture label. Then, reinstall the lens.
IMPORTANT: The bulb must be protected from moisture and dust at all
times. Always reinstall the lens when removed.