FIAMMA Turbo Vent Premium Rooflight Instruction Manual

June 6, 2024
FIAMMA

FIAMMA Turbo Vent Premium Rooflight Instruction Manual

FIAMMA Turbo Vent Premium Rooflight Instruction Manual

Package contents

FIAMMA Turbo Vent Premium Rooflight Instruction Manual - TURBO-VENT
PREMIUM

FIAMMA Turbo Vent Premium Rooflight Instruction Manual - Certified
icon

FIAMMA Turbo Vent Premium Rooflight Instruction Manual -
Dimension

  • Nominal supply voltage
  • Tension tolerance
  • Min. feeding tension
  • Maximum supply voltage.
  • Power of nominal supply voltage
  • Auto-resettable Fuse
  • Current protection intervention
  • Wire section
  • Min. electric input
  • Max. electric input
  • Operating temperature
  • Storage temperature

Check that nothing has been damaged or deformed during transport. In the event of doubts or questions concerning the installation, use or limitations of the product, contact the dealer. We recommend that the installation is carried out by qualified personnel and in compliance with current local regulations.

Installation instructions

FIAMMA Turbo Vent Premium Rooflight Instruction Manual -
STANDARD FIAMMA Turbo Vent
Premium Rooflight Instruction Manual - STANDARD

  1. Decide where the rooflight should be installed and make a square hole of 39cm. The rooflight can be installed on roofs with thickness between 30 and 85mm.
  2. Do not forget to arrange the electrical connection directly from the battery (only 12Vdc – NOT 220V).
  3. Seal the lower part of the external frame with a minimum width of 30 mm by following the appropriate rails. Recommended sealant: SIKALASTOMER-710 / THEROSTAT II / DEKALIN 1512.
  4. Place the external frame in the opening hole making sure that the hinges are facing the front of the vehicle.
  5. Fasten the external frame with 20 self tapping screws (Ø4.2x30mm UNI EN ISO 7049). Carefully silicon ate all the perimeter of the external frame, fill any spaces between the roof and the frame and all the heads of the 20 screws.
  6. Connect the input cables of the electric motor. 7) Fasten the internal frame with 8 self tapping screws (Ø3.5x15mm UNI EN ISO 7049).
    Remove the protective plastic applied to the cover (do not expose the product to sunlight for too long to avoid to make this operation difficult).

Instructions for use

FIAMMA Turbo Vent Premium Rooflight Instruction Manual - Fig
1 FIAMMA Turbo Vent Premium Rooflight
Instruction Manual - Fig 2,3 FIAMMA
Turbo Vent Premium Rooflight Instruction Manual - Fig 4 FIAMMA Turbo Vent Premium Rooflight Instruction Manual -
Fig 5 FIAMMA Turbo Vent Premium
Rooflight Instruction Manual - Fig 6

Caution! Do not reverse polarity and position of wiring.

FIAMMA Turbo Vent Premium Rooflight Instruction Manual - Fig
7 FIAMMA Turbo Vent Premium Rooflight
Instruction Manual - Fig 8

Ensure that the power supply has been disconnected before carrying out any kind of operation, then reconnect.

Safety instructions

FIAMMA Turbo Vent Premium Rooflight Instruction Manual - Polar
Control

Polar Control function

Fan ignition air inlet

Fan ignition air outlet

FIAMMA Turbo Vent Premium Rooflight Instruction Manual - Regulation fan
Speed

The Polar Control function automatically activates the ventilation depending on the set T and on the outdoor temperature.

The room temperature will be displayed by switching on the Polar Control function; by adjusting the key and the requested T, the fan will rotate until reaching the temperature set value. The switching on and off of the the Polar Control causes the RESET of the displayed room temperature. To limit the consumption of energy, we recommend to set the Polar Control to the minimum T-1°C once reached a comfortable room temperature.

Notes: the cooling capacity of the fan depends on the difference between outdoor temperature and the room temperature

T = difference between the room temperature and the required temperature.

FIAMMA Turbo Vent Premium Rooflight Instruction Manual - Polar Control
offFIAMMA Turbo
Vent Premium Rooflight Instruction Manual - Don't Do
this

In case of problems please contact your local dealer indicating the data on the nameplate. Consult our website for spare parts drawing.

Fiamma declines all responsibility for any personal injury and damage to property due to incorrect assembly or use of the product; it is suggested to keep the instructions inside the vehicle. The assembly of the product must be carried out according to the assembly instructions: the product must not be modified in any way. Before proceeding with assembly, check that the roof thickness is compatible with the product. Before choosing the place where to assembly the rooflight, check that: – the product doesn’t interfere with adjacent accessories (luggage racks, cables, reinforcements in the roof, cabinets inside the passenger compartment). – the internal and external surface of the roof is flat. Periodically check the tightness of all the screws in the rooflight, especially after the first kilometres from the installation and always before and after long trips. If the opening-closing device hardens, lubricate the lid opening device with a few drops of grease. It is forbidden to walk on the product cover. Before starting the vehicle, check that the rooflight is properly closed. Periodically check that the cover is intact. Don’t open the rooflight when the vehicle is travelling. Don’t open the rooflight in case of strong wind or rain. Remove snow or ice from the rooflight. The maximum permitted speed of the vehicle with a mounted rooflight is 130 km/h. Always comply with speed limits and the Highway Code. The speed should always be suitable to traffic conditions and transported load.

CARE AND MAINTENANCE: For the internal and external cleaning of the rooflight, always use only neutral, non-aggressive detergents. For cleaning the Crystal cover use an acrylic glass cleaner with a soft cloth so as not to scratch the surface. Never use aggressive products such as glass cleaners, all-purpose cleaners, abrasives or dish-washing detergents. Also, never use alcohol-containing detergents, solvents or any corrosive liquid. The mosquito net can be cleaned with water and a neutral detergent.

Warranty Fiamma In case of defects with regards to materials and manufacturing, the customer is entitled

to the warranty in accordance with local laws and regulations of the country in which the product was purchased.

Accessories

FIAMMA Turbo Vent Premium Rooflight Instruction Manual - THERMO
VENT

Warranty

We,
Company name: Fiamma S.p.A.
Postal address: Via San Rocco, 56
Postcode and city: Cardano al Campo – (Varese)
Telephone number: 0311/709111
E-mail address: fiamma@fiamma.it

Declare that the DoC is issued under our sole responsibility and belongs to the following product:
Apparatus model / Product: Roof Light with fun
Trademark: Fiamma

Model / Type:
04919-01y Turbo 28
C4919-01y Turbo 28 (Bulk Pack)
07903-01- Kit Turbo Vent 28 F
07903-02- Kit Turbo Vent 28 F
C7902A01y Turbo 28 F (Bulk Pack)
C7902A02y Turbo 28 F (Bulk Pack)
03623F01y Turbo Vent
03624F02y Turbo Vent
C3623G01y Turbo Vent P3 (Bulk Pack)
C3624G02y Turbo Vent P3 (Bulk Pack)
03623H01y Turbo Vent Premium
03624H02y Turbo Vent Premium
07501-01- Kit Turbo Vent F Premium
07501A01- Kit Turbo Vent F
07501B01- Kit Turbo Vent F P3

y = – White; B/D = Crystal

The object of the declaration described above is in conformity with the relevant Union harmonisation legislation:

  • 2014/30/EU Electro Magnetic Compatibility Directive (EMCD).
  • 2014/35/EU Low Voltage Directive (LVD).
  • 2011/65/EU Restriction of the use of certain hazardous substances Directive (RoHS Directive).
  • ECE/ONU/R10 Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility – R10.
  • ECE/ONU/R43 Uniform provisions concerning the approval of safety glazing materials and their installation on vehicles – R43 (only for Turbo 28, 28 F, Vent, Vent P3 and Vent Premium).
  • EN 55014-1:2006 + A1:2009+ A2:2011 – RCM (only for Turbo 28, 28 F and Turbo Vent Premium).
  • EN 61000-3-2:2014 – RCM (only for Turbo 28, 28 F and Turbo Vent Premium).
  • EN 61000-3-3:2013 – RCM (only for Turbo 28, 28 F and Turbo Vent Premium).
  • EN 55014-2:2015 – RCM (only for Turbo 28, 28 F and Turbo Vent Premium).

The following harmonised standards and/or technical specifications have been applied

Warranty Fiamma
In case of defects with regards to materials and manufacturing, the customer is entitled to the warranty in accordance with local laws and regulations of the country in which the product was purchased.

fiamma.com

Fiamma S.p.A. – Italy
Via San Rocco, 56
21010 Cardano al Campo (VA)

All rights reserved.
Fiamma S.p.A.
reserves the right to modify at any time, without notice, prices, materials, specifications and models or to cease production of any model.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>