z-WAVE PAD07 In Wall Smart Dimmer User Manual

June 6, 2024
Z-Wave

**z-WAVE PAD07 In Wall Smart Dimmer User Manual

**

Product Overview

Warning: Do not use Non-Dimmable LED lamps.

PAD07 is a security enabled wireless dimmer, based on Z-Wave Plus technology. Z-Wave Plus™ enabled devices displaying the ZWave Plus™ logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-Wave™ enabled networks. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable light bulb.
This dimmer is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-Wave™ enabled network. Since PAD07 supports Security Command Class, it can learn with a Secured enabled controller to fully utilize the device. Its functionality and supported command classes is identical when included as a secure and nonsecure device.

Specification

Rated 100-240 Vac 50Hz-60Hz 1A
Output Load Maximum 0.9A (100-240 Vac)
Fuse Information Built-in High Breaking Capacity Current Fuse Protection.

Rated: 2A; 250V Built-in Thermal Cut-off Fuses Protection.
Rated Temperature: 125°C; Rated: 2A 250V
Maximum Watts| 200W (13W x 15 pieces) (Dimmable LED bulbs) (230Vac)
Maximum Watts| 100W (6.5W x 15 pieces)or (10W x 10 pieces) (Dimmable LED bulbs); (120Vac)
Max. load (watts)| Maximum: 15 pieces (Dimmable LED bulbs)
Operating Temperature| 0°C to 40°C
Humidity| Up to 85% max
Storage Temperature| -20°C – 60°C
Location| Indoor use only
Frequency Range| 868.40MHz, 869.85MHz EU
908.4MHz, 916.0MHz US,
922.5MHz, 923.9MHz, 926.3MHz (JP)
920.9MHz, 921.7MHz, 923.1MHz (TW/KR/Thai/SG)
RF Maximum Power| +5dBm
Transmission Range| Up to 40m indoors or up to 100m outdoors (depending on building materials)
OTA| support
FCC ID| RHHPAD07
Dimensions| 47.5 x 39 x16 mm
Wire| 0.75mm² ; 18AWG

Troubleshooting

Symptom Cause of Failure Recommendation
The dimmer does not work and LED off
  1. The dimmer does not connect to electrical wire properly.
  2. Dimmer is broken.

|

  1. Check the power connections.
  2. Do not open the dimmer and send it back to distributor.

The dimmer LED illuminating, but cannot control the ON/OFF state of the load attached| Check if the load connected to the dimmer has its own ON/OFF switch| Set the ON/OFF switch of the load attached to ON
The dimmer LED illuminating, but the detector cannot control the Switch|

  1. Not carry out association
  2. Same frequency interference

|

  1. Carry out association
  2. Wait for a while to re-try

Installation

Fig 1. Assembling & Wiring

IMPORTANT

Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation.
Check your local codes as they apply to your situation. If the house wiring is of aluminum, consult with an electrician about proper wiring methods.
Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK.

For Instruction tohttp://www.philio-tech.com

Qr Code

Danger
Danger of Electrocution!

All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations. Any works introducing changes into the configuration must be always performed with disconnected voltage. Choosing a Suitable Location.

  1. Do NOT place the module/device direct under sunlight, in a humid place or in any location where they may contact moisture, dirt, dust.
  2. Do NOT place the module/device where exists combustible substance or any source of heat, fires, radiators, boiler etc.
  3. When the module/device be used, the module/device might get warm. This is a normal condition.
  4. After putting it into use. The body of Module will bexome a little bit hot of which phenomenon is normal.

Adding to Z-Wave™ Network

In the front casing, there is an on/off button (also an include button) with LED indicator below which is used to dim on and off or carries out inclusion, exclusion, reset or association. When first power applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.

Auto Inclusion

The function of auto inclusion will be executed as long as the dimmer does not have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the dimmer.
The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to Add/Remove/Reset/associate devices.

Function| Description|

Annotation

---|---|---
No node ID| The Z-Wave Controller does not allocate a node ID to the Switch.| LED 2-second on, 2- second off
Add (Inclusion)|

  1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.
  2. Pressing Include button of PAD07 three times within 2 seconds will enter inclusion mode.
  3. Node ID has been excluded.

| 0.5s On, 0.5s Off (Enter auto inclusion)
Reset|

  1. Pressing Include button of PAD07 three times within 2 seconds will enter inclusion mode.
  2.  Within 1 second, press Include button of PAD07 again for 5 seconds.

| Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
3. IDs are excluded.| 0.5s On, 0.5s Off (Enter auto inclusion)
Association|

  1. The PAD07 is an always listening Z-Wave device, so associations may be added or removed by a controller at any time. Or If your controller requires to have the PAD07 send a ‘node information frame’ or NIF for associations, then pressing the On/Off button three times within 2 seconds will cause the PAD07 to send its NIF.
  2. There are two groups for the dimmer.
  • Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node ID allocated by Z-Wave Controller means exclusion.
  • Failed or success in including/excluding the node ID can be viewed from the ZWave Controller.

LED Indication

To distinguish what mode the switch is in, view from the LED for identification.

State Type|

LED Indication

---|---
Normal| Whenever we switch On and off of the PAD07 by On/Off button or RF command, the LED will lights up when switch on; whereas LED off when switch off.
No node ID| Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing On/Off button, it will stop flashing temporarily
Learning| When PAD07 is in learning mode, LED flashes on and off alternately and repeatedly at 0.5 second intervals.

Manual dim level control:

To manually switch on the light, press and release the On/Off button or S1/S2 shortly when the light is off. The light will dim from off to the level which was set before switch off. To manually switch off the light, press and release the On/Off button or S1/S2 shortly when the light is on. To adjust the dim level, press and hold the On/Off button or S1/S2 until the desired dim level is achieved, then release.

Programming

Basic Command Class / Multilevel Switch Command Class

The dimmer will respond to BASIC and MULTILEVEL SWITCH commands that are part of the Z-Wave system. If PAD07 is included as a secured node, it will only response to the security encapsulation command of BASIC and MULTILEVEL SWITCH.

  1. BASIC_GET / MULTILEVEL_SWITCH_GET
    Upon receipt of the following commands from a Z-Wave Controller, the Switch will report its dimmer state to the node inquired.
    Basic Get Command: [Command Class Basic, Basic Get] Basic Report Command:
    Report OFF: [Command Class Basic, Basic Report, Value = 0]
    Report ON: [Command Class Basic, Basic Report, Value = 1~99] Multilevel Switch Get Command: [Command Class Multilevel Switch,
    Multilevel Switch Get]

    Multilevel Switch Report Command:
    Report OFF: [Command Class Multilevel Switch, Multilevel Switch Report, Value=0]
    Report ON: [Command Class Multilevel Switch, Multilevel Switch Report, Value =1~99]

  2. BASIC_SET / MULTILEVEL_SWITCH _SET
    Upon receipt of the following commands from a Z-Wave Controller, the load attached to the dimmer will turn on or off.
    [Command Class Basic, Basic Set, Value = 0] : the load attached to the
    dimmer turns off.
    [Command Class Basic, Basic Set, Value = 1~99] : the attached load
    dim on as the level.
    [Command Class Multilevel Switch, Multilevel Switch Set, Value=0,
    Duration = 0~255] : the load attached to the dimmer turns off.
    [Command Class Multilevel Switch, Multilevel Switch Set, Value
    =1~99, Duration = 0~255] : the attached load dim on as the level.

Z-Wave’s Groups

The Switch can be set to send reports to associated Z-Wave devices. It supports one association group with five nodes support for grouping 1. For group 1,
the dimmer will report MULTILEVEL_SWITCH_REPORT, ALARM_REPORT
and DEVICE_RESET_LOCALLY_NOTIFICATION.

Grouping 1 Lifeline(Maximum 5 nodes)
Device reset locally notification :
When PAD07 is reset manually, it will send a DEVICE_RESET_LOCALLY_NOTIFICATION to the nodes of group 1.
On/Off Event Report
When “on” or “off ” state has been changed, it will send Multilevel Switch Report
to the nodes of Grouping 1.

Multilevel Switch Report
ON: [Command Class Multilevel Switch, Multilevel Switch Report,
Value =1~99]
OFF: [Command Class Multilevel Switch, Multilevel Switch Report,
Value =0(0x00)]

Overload alarm report

When PAD07 detects the Overload, it will send Alarm Report to Group 1 nodes. After detecting overload state and sending this alarm report, PAD07 will turn off the dimmer automatically and lockout the On/Off button and S1/S2. The only thing to do is unplug PAD07 and reduce the load. Then re-power on PAD07 and it will work again.
The content of Alarm Report
Alarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type
= 0x08, Alarm Level = 0xFF]

Grouping 2 Control_Key1 : (Maximum 5 nodes)

When the On/Off status changes or the dim level is achieved manually, it will send BASIC_SET command to group 2 nodes to make them unanimous.

Dimmer Off : [Command Class Basic, Basic Set, Value = 0] Dimmer On : [Command Class Basic, Basic Set, Value = 1~99]

Z-Wave’s Configuration

Configuration Parameter| Function| Size (Byte)| Value| Unit| Default| Description
---|---|---|---|---|---|---
| Dimmer Level Report mode| 1| 0-1| | 1| 0 : Disable
1 : Enable
2| LED indication mode| 1| 1-3| | 1| 1: Show dimmer state
2 : Show night mode 3: One flash mode
3| External switch type| 1| 1-3| | 1| 1 : One switch mode 2 : Two switch mode 3: Up/Down switch mode
4| Restore dimmer state| 1| 0-2| | 1| 0 : Dimmer off
1 : Last dimmer state
2 : Dimmer on

  1. Dimmer level report mode :
    Whenever dimmer on/off state changes, it will send MULTILEVELSWITCH REPORT to the nodes of group1. The default setting is Enable the function.

  2. LED indication mode :

  3. Show dimmer State: When dimmer is on, LED is on. When dimmer is off, LED is off. The default setting is Show dimmer State.

  4. Show Night mode: When dimmer is on, LED is off. When dimmer is
    off, LED is on.

  5. One flash mode: When dimmer on/off state changes, LED will light on one second and then off.

  6. External switch type:

  7. One switch mode: Only S1 can dim up the light bulb to brightest level, then dim down to darkest level, and so on…

  8. Two switch mode: S1 and S2 can dim up the light bulb to brightest level, then dim down to darkest level, and so on…

  9. Up/Down switch mode: S1 can only dim up the light bulb to brightest level, and S2 can only dim down to Off.

  10. restore dimmer state :
    Whenever the AC power return from lost, PAD07 will restore the switch state
    which could be Dimmer off、Last dimmer state、Dimmer on. The default setting is Last dimmer state.

Firmware update over the air (OTA)

PAD07 is based on 500 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Z-wave RF media. It is a helpful and convenient way to improve some function if needed.

Command Classes

The Switch supports Command Classes including…

  • COMMAND_CLASS_ZWAVEPLUS_INFO
  • COMMAND_CLASS_VERSION_V2
  • COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
  • COMMAND_CLASS_SECURITY
  • COMMAND_CLASS_DEVICE_RESET_LOCALLY
  • COMMAND_CLASS_ASSOCIATION_V2
  • COMMAND_CLASS_ASSOCIATION_GRP_INFO
  • COMMAND_CLASS_POWERLEVEL
  • COMMAND_CLASS_BASIC
  • COMMAND_CLASS_SWITCH_MULTILEVEL_V2
  • COMMAND_CLASS_CONFIGURATION
  • COMMAND_CLASS_ALARM
  • COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
  • COMMAND_CLASS_SCENE_ACTIVATION
  • COMMAND_CLASS_SCENE_ACTUATOR_CONF

Disposal

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems.
or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

Philio Technology Corporation
8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City
24257, Taiwan(R.O.C)
www.philio-tech.com

FCC Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.