TRACO POWER TML 20 Series Switching Power Supply Instruction Manual
- June 6, 2024
- TRACO POWER
Table of Contents
TRACO POWER TML 20 Series Switching Power Supply
INSTALLATION INSTRUCTIONS
Order Code | Output Power max. | Output 1 | Output 2 | Output 3 |
---|---|---|---|---|
TML 20103 | 14.85 Watt | 3.3Vdc / 4500mA | ||
TML 20105 | 20 Watt | 5.0Vdc / 4000mA | ||
TML 20107 | 20 Watt | 7.35Vdc / 2730mA | ||
TML 20109 | 20 Watt | 9.0Vdc / 2230mA | ||
TML 20112 | 20 Watt | 12.0Vdc / 1670mA | ||
TML 20115 | 20 Watt | 15.0Vdc / 1340mA | ||
TML 20124 | 20 Watt | 24.0Vdc / 840mA | ||
TML 20205 | 20 Watt | +5.0Vdc / 2000mA | -5.0Vdc / 2000mA | |
TML 20212 | 20 Watt | +12.0Vdc / 830mA | -12.0Vdc / 830mA | |
TML 20215 | 20 Watt | +15.0Vdc / 670mA | -15.0Vdc / 670mA | |
TML 20512 | 20 Watt | +5.0Vdc / 2800mA | +12.0Vdc / 250mA | -12.0Vdc / 250mA |
TML 20515 | 20 Watt | +5.0Vdc / 2800mA | +15.0Vdc / 200mA | -15.0Vdc / 200mA |
Add C behind the order code for chassis mounting version with screw-type terminals.
Input Voltage Range:| 90 – 264Vac / 47 – 440Hz| Load Derating:| all models:
above +50°C of 3.75%/°C
---|---|---|---
100 – 375Vdc| Terminal for wiring:| PCB mounting with solder pin’s or
Screw type terminal: Wires 1.5mm2 max Recommended tightening torque
0.5 to 0.7Nm (4.5 to 6.2lb.in.)
Input current:| 0.400A typ at Vin = 115VAC 0.270A typ at Vin = 230VAC
Output voltage accuracy| ±2.0%
Operating temperature range:| -25°C – +71°C max| Case material:| Plastic Resin
- Fiberglas UL 94V-0 flammability rating
Case Temp.| +95°C max.
Safety Instructions:
- Before installation read these instructions carefully and completely. This installation instruction can not claim for every possible example of installation, operation, or maintenance. Further information’s area fro your caldistributorofficeor from the product datasheet which can be downloaded from the Internet at http://tracopower.com.
- The power supplies are constructed in accordance with the safety requirements of IEC/EN/UL60950 1. They fulfill the requirements of the Low voltage directive (LVD) and carry the CE mark. They are and cUL approved in accordance withUL60950 1 (recognized).
- Before any installation, maintenance, or modification work ensure that the main switch is switched off and prevented from being switched on again. In case of nonobservance touching at any alive components or improper dealing with this power supply can re sultan death, severe personal injury, or substantial property damage. Successful and safe operations are dependent on proper storage, handling, installation, and operation.
- Compliance with the relevant national regulations (in the USA, Europe, and other countries) must be sure. Before the operation is started the full owing conditions must be ensured:
- Connection to the mains supply in compliance with national regulations (VDE0100 and EN50178).
- By use of stranded wires, all strands must be fastened in the terminal blocks.
- The power supply and main cables must be sufficiently fused.
- All output wires must be rated for the power supply output current and must be connected with the correct polarity.
- Sufficient cooling must be ensured.
- Keep away from fire and water
- Never work on the power supply if power is supplied! Risk of electric arcs and electrical shock which can cause death, severe personal injury or substantial property damage.
- Never work on the power supply if power is supplied! Risk of electric arcs and electrical shock which can cause death, severe personal injury or substantial property damage.
- Warning: Hazardous voltages and components storing a very substantial amount of energy are present in this power supply during normal operating conditions. However, these are inaccessible. Improper handling may result in an electric shock or serious burns!
Installation Instructions:
- This power supply is designed for professional indoor systems. In operation, the power supply must not be accessible. It may be installed and put into service by qualified personnel only.
- The correct mounting position for optimal cooling performance must be observed. Observe powerderating. (see datasheet)
- Recycling: The unit contains elements that are suitable for re-cycling and components which need special disposal. You are therefore requested to make sure that the power supply will be recycled by the end of its service life.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>