SURGICALLY CLEAN AIR ONYX Air Purifier User Manual

June 12, 2024
SURGICALLY CLEAN AIR

SURGICALLY CLEAN AIR LOGO ONXY SCA (SCA2000C)
OPERATION MANUALSURGICALLY CLEAN AIR ONYX Air PurifierRead the manual thoroughly before
operation and retain for future us. LISTED
E520581

SAFETY PRECAUTIONS 1

The internal UV-C+ lamp contains a small amount of mercury which is contained inside the bulb unless broken. Mercury and mercury compounds are known to the State of California to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
Be sure to follow all precautions below:
Running Environment Cautions

  • Use only a 120-volt outlet with grounding wire receptacle.
  • Do not put it in rooms with high heat, damp or wet places.
  • Best working condition is 10-40ºC.
  • This unit should be installed on a load bearing wall near the indoor personnel activity.
  • To reduce the risk of electric shock, this equipment has a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet, contact qualified personnel to install the proper outlet. Do not alter the plug in any way.
  • This product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on an averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room approximately 30 m³.

Unit Operation

  • Do not insert fingers or foreign objects into the intake or air outlet.
  • Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.
  • Do not block the air intake and air outlet.

SAFETY PRECAUTIONS 2

  • Do not use the air purifier if the power cord or plug is damaged or the connection to the wall outlet is loose.
  • When removing the power plug, always hold the plug and never pull by the cord.
  • Do not use the unit near or on hot objects, such as range or where it may be exposed to steam.
  • Stop the unit and unplug the power when maintenance.
  • To avoid causing fire and/or shock do not attempt to disassemble the unit – only certified technicians should do this.
  • Do not wash or reuse the Pre-filter, HEPA-Rx filter and the Activated carbon filter.

HOW IT WORKS

When the DC fan motor is running, the indoor air will be drawn through the bottom of the unit. The air will then pass through the Pre-filter, the HEPA-Rx Filter, the Activated Carbon Filter, and the UV-C+ Lamp Holder.The purified air is then released through the outlet on the top of the unit. The Revitalizing Negative Ion Generators near the air outlet releases revitalizing negative ions into the air.

SURGICALLY CLEAN AIR ONYX Air Purifier - WORKS

The air is purified in multiple stages:

  1. PRE-FILTER
  2. ULTRAFINE HEPA-Rx PARTICULATE FILTER
  3. ACTIVATED CARBON FILTER
  4. UV-C+ LAMP
  5. REVITALIZING NEGATIVE ION CHAMBER

FEATURES AND SPECIFICATIONS

The unit has a Pre-filter, HEPA-Rx Filter, Activated Carbon Filter, UV-C+ Lamp and Revitalizing Negative Ion generator.
Automatic Function
The odor and particle sensor can let the unit automatically select the appropriate fan speed depending on the air quality detected.
Filters and UV Lamp Replacement Indicator Lights
The indicator lights tell you when to replace the Pre-filter, HEPA-Rx filter and the Activated carbon filter or the UV-C+ lamp.
Easy Maintenance and Low Cost
When the filters need to be replaced, simply open the front panel and pull out the filters and put the new ones in. No screws, hooks or tools are required.

Model No. ONYX   (SCA2000C)
Power Requirement 120V, 60Hz
Rated Power 96W, 1.1A
Negative Ion 3×10 6/cm³
UV Lamp 24W
Dimensions 45cm x 78cm x D19.5cm (17.7 inches x 30.7 inches x D7.7)
Weight 18.5kg (40.8pounds)

PART NAME

SURGICALLY CLEAN AIR ONYX Air Purifier - PART NAME

01- Front panel
02- Lock
03- Key
04- Display panel back cover
05- LED Display circuit board
06- Fan motor front panel
07- Maintenance panel
08- Remote control
09- Fan motor top cover
10- Fan motor system| 11- Unit housing
12- UV ballast
13- UV light blocker
14- UV-C+ Lamp
15- Activated carbon filter
16- HEPARx filter
17- Pre-filter
18- Unit hanging board
19- Screws
---|---

INSTALLATION

  1. Power supply condition: Use only a 120-volt outlet with grounding wire receptacle.
  2. This product should be installed on the wall. It must be installed on the wall of the load-bearing wall, otherwise it will cause the unit to fall and potentially harm someone.
  3. Prior to using unit for the first time, you must remove the plastic bag from the Pre-filter, HEPA-Rx filter and the Activated carbon filter inside the unit.

Install the unit

  1. Use an impact drill holes on the load-bearing wall according to the hole position on the unit hanging board.
  2. Use expansion bolts and self tapping screws to firmly fix the unit hanging board. Fix with at least 4 more screw holes on the hanging board (2 on top and 2 on bottom).
  3. Carefully hang the unit on the upper and lower hooks of the hanging board. Pull the unit down with both hands to check whether the unit is firmly hung on the hook.

SURGICALLY CLEAN AIR ONYX Air Purifier - Install

OPERATION

OPERATION 1
Button Operation and Display Indicator Lights

SURGICALLY CLEAN AIR ONYX Air Purifier - OPERATION

Button Operations

  1. POWER Button
    – Turns the unit On and Off.
    – Hold the button for 2 seconds, the “ ” indicator light will light up with beeping. In this mode, the panel is locked. If you want to return to the default mode, do the reverse.

  2. SPEED Button
    When this button is pressed the airflow rate changes as shown below:
    L– M — H — Auto…

  3. TIMER Button
    Press this button to select the time for operation. The timer setting switches as shown: 1 — 2 — 4 — C (timer cycle function) — cancel timing.
    Display Indicator Lights

  4. SPEED indicator lights- low, medium and hight

  5. AUTO mode indicator light
    When this lights up, the unit is at Auto mode: the unit will operate on low speed and will adjust speeds accordingly base on what pollution the sensors pick up in the air.

  6. UV-C+ Lamp indicator light
    When this lights up the UV-C+ light is on. When the indicator light flashes, it is time for the UV-C+ Lamp to be replaced.
    OPERATION 2
    Display indicator lights

  7. NEGATIVE ION indicator light
    When this light is on, negative ions are discharged.

  8. TIMER CYCLE indicator light
    When this indicator is lighting up, the unit will start to work for 2 hours and stops 0.5 hour automatically – this schedule will repeat itself continuously while in this mode.

  9. TIMER indicator light
    – Displays the current clock time when the unit has no time set.
    – When pressing the TIMER button on the display panel or the TIMER button on the remote control, the time is displayed, and the “ ” indicator light is on.
    – When the scheduled operation time is set, the “OFF” indicator will light up under the running state and display the shutdown time. When in the power off state, the “ON” indicator will light up and display the power on time.

  10. PM2.5 display
    Real-time display the indoor PM2.5 concentration (μg/m³).

  11. Indoor humidity display

  12. Indoor TVOC pollution level display

  13. LOCK FUNCTION indicator light
    In this mode, all the buttons will not work.

  14. Pollutant level display (See the chart)
    Indicator| PM2.5| TVOC Level| Speed
    ---|---|---|---
    Green| ≤75μg/m³| | L
    Orange| 75~150μg/m³| | M
    Red| >150μg/m³| | H

The different colors indicate the air quality:
Green=Good
Orange=Moderate
Red=Poor

  1. FILTERS LIFE indicator lights (See the chart)
    Indicator| Instructions
    ---|---
    E| Replace the Pre-filter
    H| Replace the HEPA filter
    C| Replace the Activated Carbon filter

OPERATION 3
Remote Control Operation

SURGICALLY CLEAN AIR ONYX Air Purifier - Remote
Control

  1. Power (ON/OFF) Button
    The unit will start operating when the POWER button is pressed.
    Pressing the button again will stop operation.

  2. Scheduled operation time Buttons
    a. The first time press the “TIME” button, the digital clock on the display panel flashes – calibrate the current time by pressing the “+” or “-” buttons – then press the “▶” button, the minute display starts flashing. Also calibrate the current minute by pressing the “+” or “-” buttons.
    b. Press the “TIME” button a second time, the “ON” indicator light on the display panel is light on. At this point, press the “+” or “-” buttons to set the start time of the unit through the same time setting method.
    c. Press the “TIME” button a third time, the “OFF” indicator light on the display panel is light on. At this point, according to the same time setting method, press the “+” or “-” buttons to set the unt’s shutdown time.
    d. Press the “ ” button to confirm the above time setting. At this time, the unit is turned on and off at the set time every day.

  3. SPEED Button
    The fan speed can be switched among L- M- H- Auto settings.

  4. NIGHT Button
    When pressed, all the indicator lights on the display panel will go out.

  5. UV-C+ LAMP Button: Turns UV-C+ lights on and off.

  6. NEG.ION Button: Turns Negative Ions on and off.

  7. TIMER Button

  8. The set time switches every time the button is pressed as shown below:1hr – 2hr – 4hr – Cycle – Cancel.

  9. RESET Button
    Pressing the reset button 3 times will reset the replacement indicator lights.

CARE AND MAINTENANCE

CARE AND MAINTENANCE 1
To maintain optimum performance of this air purifier, the Pre-filter, the HEPA-Rx Filter, the Activated Carbon Filter and the UV-C+ Lamp need to be replaced when the indicator lights are flashing. If in an atmosphere with heavy dust, particulate or pet dander, you may need to periodically vacuum the filters for optimal performance.
Make sure all the filters are installed properly before operating the unit.
Filters Life

  1. Pre-filter needs to be replaced once every 6 months (running 24/7).
  2. Activated Carbon Filter needs to be replaced once every 6 months (running 24/7).
  3. HEPA-Rx Filter needs to be replaced once a year (running 24/7).
  4. UV-C+ Lamp needs to be replaced once a year (running 24/7).

Main Unit
Wipe with a dry, soft cloth for stubborn stains or dirt. Do not use volatile fluids, benzene, paint thinner or polishing powder as this may damage the surface.
Do not use detergents as detergent ingredients may also damage the unit. Keep the unit away from water.
Warning

  1. Turn off and unplug the power cord before cleaning the body, air outlet or opening the front panel to avoid electric shock.
  2. Turn off and unplug the power cord before replacement of the Pre-filter, HEPA-Rx Filter, Activated Carbon Filter and the UV-C+ Lamp or unit maintenance. If the power cord is damaged, it must be replaced by the service center or a similarly qualified person.

CARE AND MAINTENANCE 2
Replace the Pre-filter and the HEPA-Rx filter
When the “E” indicator light on the control panel flashes, the Pre-filter needs to be replaced.
When the “H” indicator light on the control panel flashes, the HEPA-Rx filter needs to be replaced.

  1. Open the front panel
    • Stop the operation and unplug the unit.
    • Rotate the door key and open the front panel.SURGICALLY CLEAN AIR ONYX Air
Purifier - front panel

  2. Take off the maintenance panel
    Turn the plastic holder to the right and remove the maintenance panel.SURGICALLY CLEAN AIR ONYX Air Purifier - maintenance
panel

  3. Removing the Pre-filter
    • Pull the Pre-filter out slightly.SURGICALLY CLEAN AIR ONYX Air Purifier -
Pre filter

  4. Removing the HEPA-Rx filter
    • Pull the HEPA-Rx filter out slightly.SURGICALLY CLEAN AIR ONYX Air
Purifier - HEPA Rx filter

CAUTION:

  • DO NOT reuse or clean the Pre-filter or the HEPA-Rx filter with alcohol, gasoline, paint thinner or other flammable substances. It may cause fire!
  • Remove plastic packaging from the Pre-filter and the HEPA-Rx filter before operation.
  • After replacing the Pre-filter or the HEPA-Rx filter, hold the SPEED button on the display panel 3 seconds or press the RESET button on the remote control 3 times to reset the time for the Pre-filter or the HEPA-Rx filter.

CARE AND MAINTENANCE 3
Replace the Activated carbon filter and the UV-C+ Lamp
When the “C” indicator light on the control panel flashes, the Activated carbon filter needs to be replaced.
When the “ ” indicator light on the control panel flashes, the UV-C+ lamp needs to be replaced.

  1. Removing the Activated carbon filter
    • Stop the operation and unplug the unit.
    • Open the front panel and take off the maintenance panel.
    • Pull out the activated carbon filter.SURGICALLY CLEAN AIR ONYX Air
Purifier - carbon filter

  2. Replace the UV-C+ lamp
    • Hold the UV-C+ lamp, pull it up and remove it from UV-C+ lamp holder.SURGICALLY CLEAN AIR ONYX Air Purifier - lamp

Reset the filters life
After replacing the Activated carbon filter or the UV-C+ lamp, hold the SPEED button 3 seconds or press the RESET button on the remote control 3 times to reset the time for the Activated carbon filter or the UV-C+ lamp.
WARNING:

  • Never look directly at UV-C+ lamp. Direct exposure to germicidal light can cause temporary or chronic damage to your eyesight, or even blindness.
  • Do not dispose of the UV-C+ lamp with normal household waste, hand it in at an official collection point for recycling.

TROUBLESHOOTING

Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by reviewing the following guide. All other servicing should be done by a SCA authorized service center.

Failure phenomenon Checking Method
The unit does not operate. Power plug disconnected? Make sure plug is fully

inserted.
Maintenance panel or interlock switch failure?| The unit does not operate when the maintenance panel is detached. Install properly. Check interlock switch.
Power failure?| Check other electrical appliances.
When functions do not work properly.| There is too much dust on the Pre- filter, HEPA -Rxfilter or the Activated carbon filter?| Replace the Pre- filter, HEPA-Rx filter or the Activated carbon filter.

UV-C+ lamps should only be purchased from Surgically Clean Air or an authorized dealer at Surgically Clean Air. This will ensure that you are receiving UV-C+ lamps that do not produce ozone. Many after-market sellers are selling ozone-generating UV-C+ lamps.

SURGICALLY CLEAN AIR LOGO1A – 6300 Viscount Road
Mississauga, Ontario
Canada, L4V 1H3
Tel: 1-877-440-7770
www.surgicallycleanair.com
info@surgicallycleanair.com