ProPlex FloppyDrive Digital DIN Rail Mount User Guide

June 6, 2024
ProPlex

ProPlex FloppyDrive Digital DIN Rail
Quick Start Guide

Setup

ProPlex DIN-Rail devices use a standard Phoenix MSTB screw terminal connector in various pin configurations. Please refer to the wiring diagrams below for the correct hook-up of your ProPlex DIN Rail product.

The ProPlex FloppyDrive Digital DIN Rail must operate at 24 VDC. It can drive a maximum of 15m of 12W per meter Firefly FloppyFlex Digital LED neon and can control a maximum of 120 pixels of RGB.
Addressing and mode selection is done via RDM protocol.

  1. Connect the DC power (24V) to the power input located in the left top corner. The connector should be wired as follows:

  2. Connect the DMX signal input to the DMX input located in the right top corner of the unit. The connector should be wired as follows:
    2.1 To pass DMX to another device, connect the DMX cable to the DMX Thru port located in the right top corner of the unit. The connector should be wired as follows:

  3. Connect the FloppyFlex Digital to the output connector of the floppy drive Digital DIN Rail.
    The connectors should be wired as follows:

Connection Scheme for FloppyFlex Digital

Connection scheme for DMX Thru-Port usage

Dimensions and Connections

LED Status Information

The Power LED has two states: ON and OFF.

  • ON: Unit is receiving power
  • OFF: Unit is not receiving power

The DMX input activity LED has two states: OFF and BLINKING YELLOW.

  • OFF: There is no active incoming DMX signal.
  • BLINKING YELLOW: There is an active incoming DMX signal.

DMX values for FloppyFlex Digital output

Channel Value Function Pixel numb.
1 000 k- j 255 RED intensity 0% -100% 1
2 000 k- j 255 GREEN intensity 0% – 100% 1
3 000 Ei. 255 BLUE intensity 0% – 100% 1
4 000 k- j 255 RED intensity 0% -100% 2
5 000 k- j 255 GREEN intensity 0% -100% 2
6 000 k- j 255 BLUE intensity 0% – 100% 2
358 000 L-j. 255 RED intensity 0% -100% 120
359 000 k- j 255 GREEN intensity 0% -100% 120
360 000 k- j 255 BLUE intensity 0% – 100% 120

CONTACT INFORMATION

LOS ANGELES HEADQUARTERS
527 Park Avenue | San Fernando, CA 91340, USA
Tel: +1 818.899.8818 | Fax: +1 818.899.8813
sales@tmb.com

TMB 24/7 TECH SUPPORT
US/Canada: +1.818.794.1286
Toll Free: 1.877.862.3833 (1.877.TMB.DUDE)
UK: +44 (0)20.8574.9739
Toll Free: 0800.652.5418
techsupport@tmb.com

LOS ANGELES +1 818.899.8818
LONDON +44 (0)20.8574.9700
NEW YORK +1 201.896.8600
BEIJING +86 10.8492.1587
CANADA +1 519.538.0888

www.tmb.com

A full-service company providing technical support, customer service, and follow-up.
Providing products and services for the industrial, entertainment, installation, defense, broadcast, research, telecommunications, and signage industries.
Servicing the global market from offices in Los Angeles, London, New York, Toronto, and Beijing.
ProPlex FloppyDrive Digital DIN Quick Start Guide, v1.2 14 June 2021

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals