InfiRay M200 Series Handheld Thermal Camera User Manual

June 6, 2024
InfiRay

M200 Series
Handheld Thermal Camera
User Manual V1.0.1

IRay Technology Co., Ltd.
www.infiray.com

Introduction to IRay Technology

IRay technology Co., Ltd. concentrates on developing infrared thermal imaging technologies and manufacturing relevant products, with completely independent intellectual property rights. Italy is committed to providing global customers with professional and competitive infrared thermal imaging products and solutions. The main products include IRFPA detectors, thermal imaging modules, and terminal thermal imaging products.

With R&D personnel accounts for 48% of all employees, 662 intellectual property projects in terms of IRay have been authorized and accepted: 522 patented technologies authorized and accepted in China (including those for integrated circuit chips, MEMS sensors design and manufacture, Matrix III image algorithms and intelligent precise temperature measurement algorithms, etc.); 16 patented technologies authorized and accepted overseas; 86 software copyrights and 38 integrated circuit layout designs. The statistic data is up to April 2021

many products have been applied in various fields, including epidemic prevention and control, industrial thermography, security and fire control, night-vision observation, automatic driving, Internet of Things, AI, and machine vision.

©IRay Technology Co., Ltd. 2021 Reserve all the rights.

All in this manual including texts, pictures, diagrams, and other contents belong to IRay Technology Co., Ltd (Hereinafter referred to as “Our company” or “IRay Photoelectric”). Without the written permission, no one shall copy, photocopy, translate or disseminate all or part of this manual. Any third party shall not modify, crack, decompile or delete the documents, systems, software, and programs contained in the terminal product without the consent of the company before the terminal product is sold to the end-user, and shall not dismantle the terminal product or preinstall other equipment on the terminal product without authorization. The Company authorizes end users to use the products within the scope of authorization of the terminal equipment and in the areas where the terminal products have obtained patent rights. Anyone shall not dismantle, modify, crack, decompile or make other changes to the terminal equipment without authorization or through any third party. The users should bear the relevant responsibilities of terminal product damage, abnormal function, the unstable operation caused by the above behaviors without authorization. In case of any damage caused by the above behaviors, the company reserves the right to pursue its legal liability.

Notices to the User

Calibration

We recommend that you conduct calibration once a year.

Accuracy

For very accurate results. we recommend that you wait 5 minutes after you have started the camera before measuring a temperature.

Manual Update

The user manual will be updated from time to time. Please contact our company to get the latest version. 1.4 Scope of Application

This manual is applicable for all products in a range. which means that parts of the manual may not apply to a particular model.

Quick Start Guide

Steps to Start:

  1. Charging
    • 5V 1A or 5V 2A power adapter and USB cable can be used to charge the
    • You can charge the device by connecting the USB cable in the accessory to the
    Note: This method of charging takes a longer time than using the power adapter.
    • A charging base can also be used to charge the battery.

  2. Power on
    Long press the power button to start the device.

  3. Target Searching
    Point the thyme camera at the object of interest

  4. Image Capturing
    Click the trigger button to capture the image. and record the video by long- pressing the trigger button.

  5.  Analysis by PC Software
    Run the client after downloading the software to PC, and then use a USB cable or SD card to import data for further analysis.
    Note: please import the files naming XX-IR.jpg (Infrared images with temperature data) and files naming XX-DC.jpg (visible images) together.

  6.  Analysis by App
    Download and install the App on the mobile device and run the App. Open camera Wi-Fi, then connect the mobile device to the hotspot of the camera and import the data for further analysis.

Product Introduction

Camera( View from the front)
No. Component Introduction
1 Digital Camera
2 Infrared Lens
3 Laser Pointer
4 Trigger
Buttons(View from the rear)
No. Component Introduction
1 Touch screen
2 Gallery button

Press to open the gallery. Long press to perform image uniformity correction. Long press to perform manual shutter.
3| Navigation button
Make selections for the menu, settings, gallery by clicking up/down/left/right.
4| Power/Laser button
Long press to turn on/off. When the camera is on, short press the button to turn on/off the laser pointer.
5| Back button
Short press to cancel the operation or return to the previous menu.
Long press to perform image uniformity correction.
6| Enter button
Click OK to confirm the operation.
7| Microphone
It’s used to record voice notes after image capturing.

Connector and Memory Card
No. Component Introduction
1 USB Interface
  • Connect a USB cable with the power adapter for charging.
  • Connect a USB cable to a computer to charge or transfer data.

2| SD Card

  • Standard MicroSD card, standard 32GB, Max 32GB.
  • The SD card can be taken out and transferred data to a PC or other devices with a card reader.

User Interface

No. Interface Introduction
1 Main Menu: measurement parameters, measurement mode, image mode, color

palettes, and other settings can be set.
2| Sub Menu: specific options can be set, such as a specific color palette.
3| Temperature measurement spot: measurements of center spot, high/low- temperature spot tracking, custom spot, custom line, custom region measurements are available.
4| Center spot temperature: the temperature of the center spot is displayed.
5| Date and time: date and time are displayed.
6| Battery capacity: the remaining battery capacity is displayed.
7| Temperature range: the temperature range in the current screen can be displayed.

Operation Instruction

 Charging
Charge with a Power Adapter
  1. Plug the power adapter into the socket.
  2. Use a USB cable to connect the adapter and the camera to charge. Note: It takes about 3h to get the device fully charged.
Charge with a Computer
  1. Use a USB cable to connect the thermal camera to the computer to charge.

Note: when charging vAth a computer. the computer should be turned on. and the charging time is longer than using an adapter.

 Charge with a Charging Base
  1. Connect the power adapter and the charging base with a USB cable. and plug the power adapter into the socket.
  2. Take out the battery and place it correctly in the charging base to charge.

Note: When the battery is not placed. the indicator of the charging base flashes: the indicator turns red when the battery is placed and charging: the indicator becomes green when the battery is fully charged.

Power On/Off
  1. Press the power button continuously to start the device.
  2. Press the power button for about 3 seconds to turn it off.

Image CapturingNideo Recording

  1. In the observation interface, adjust the focus ring till the image is dear. Short press the trigger button to take the photo. Long press the trigger button to start recording the video and finish recording by releasing the trigger button.
  2. Tap the save button on the screen or click OK to save the *lure. Tap other buttons on the screen or use the navigation button + OK to make recording annotation. scan the OR code to name the file. or cancel saving photos.
View PhotosNideos

The pictures you took are saved on the SD card, and you can follow the below steps to view them at any time.

  1. Enter the image archive by clicking the gallery button.
  2. Select the picture or video you want to view by pressing the navigation button or screen.
  3. Press OK or dick the image or video to view it in full Select the delete option and then confirm to delete the current item. Select the rename option and confirm to rename the current item.
  4. When in the preview interface, click the multiple buttons in the upper right corner of the screen, then select the image or video to be deleted, and delete the selected items by pressing the delete button.
  5. Return to the observation interface by clicking the gallery button, back button, or touching the screen.
Measurement Mode

In the observation interface. press OK shortly to enter the main menu. and select ‘Measurement Settings” with the navigation button. Press OK again to enter the secondary menu. select different measurement modes by shifting left or right on the navigation button. and press OK to save your option.

In the observation interface. click anywhere on the screen to enter the main menu. Then click ‘Measurement Settings’ to select the desired measurement mode. and make it effective by clicking the screen area.

Measurement Parameters

In the observation interface, press OK to enter the main menu, use the navigation button to select the ‘parameter setting, then press OK again to enter the secondary menu. Select different temperature measurement parameters by shifting left or right, and press the enter button to parameterize. After setting. Press OK again to save your option.

In the observation interface, dick anywhere on the screen to enter the main menu. Click ‘Parameter Setting’ to set the parameter. After finishing the setting. click the screen area to take effect.

  • Emissivity: in order to obtain more accurate measurement results, you need to set the emissivity according to the target to be measured before each instead of using the default configuration. Emissivity refers to the ratio of the radiant ability of an object to the radiant ability of a blackbody at the same temperature, which is relative to the reflectivity of the object The lower the emissivity. the higher the proportion of energy being reflected. The higher the emissivity, the lower the proportion of energy being reflected. For example. the emissivity of human skin is 0.98. and the emissivity of printed circuit boards is 0.91. For more information on emissivity, you can refer to the quick start guide in the package or inquire from other sources.

  • Ambient temperature: the reflection temperature of the object’s surface will affect the measurement result. especially when the object emissivity is low or the object temperature and the reflection temperature differ greatly, this effect will increase. So the result needs to be compensated to eliminate influences of the surface reflection temperature. However, it is usually difficult to determine the reflected temperature of an object. The ambient temperature can be used to replace the reflected temperature in the actual measurement.

  • Distance: distances have effects on the measurement results. In order to get accurate distance information of the object is necessary for the thermal camera to compensate for the result.

Palettes

In the observation interface, short press OK to enter the main menu. and select “palette setting” with the navigation button. Press OK again to enter the sub-menu. select different palettes by shifting left and right on the navigation button, and then press the enter button to save your option.

In the observation interface. click anywhere on the touch screen to enter the main menu. Click ‘palette setting’ to choose a palette and save your option by clicking the screen area.

 Image Mode
Image Mode Introduction

Four image modes are available.

  • Thermal Fusion: an image fused to a certain scale between an infrared image and a visible image
  • PIP: infrared image superimposed at the center of the visible image
  • Thermal imaging: infrared images
  • Digital camera: visible images

Note: For better dual-light image effects. when in PIP a thermal fusion modes. you need to set the actual distance. that is. the approximate distance from the thermal camera to the object. If the preset registration parameters cannot meet the requirements. you can also manually perform fusion registration in the settings.

Setting Steps

In the observation interface. press OK shortly to enter the main menu. and select ‘image mode” through the navigation button. Then press OK again to enter the secondary menu. their different image mode can be selected by shifting left or right on the navigation button. Save your option by pressing the enter button.

In the observation interface. Click any place on the screen to enter the main menu. Click ‘image mode” and select the desired image mode, and then click on the screen area.

Non-uniformity Correction
Non-uniformity Correction Introduction

Non-uniformity correction is used to compensate for the non-uniformity of detector pixels or non-uniformity caused by other optical interference. When there is more noise in the image. non-uniformity correction is needed. which is common when the ambient temperature changes rapidly.

Non-uniformity Correction Operations

In the imaging interface. long-press the back button or the gallery button to perform non-uniformity correction.

Contrast Adjustment

In the observation interface. the contrast of the infrared image can be adjusted by sliding up and down the arrow button on the “temperature range’ on the right side of the screen.

Press “A” in the upper right corner of the interface to return to auto- contrast mode.

Digital Zoom

In observation interface. Press the left or right navigation button to perform Max. 4 digital zooms. Note: this function is only enabled under infrared mode or visible mode.

Other Settings

Other settings include date and time, unit. language and other items.

  1. In the observation interface. press OK shortly to enter the main menu. and select “Settings” to enter other settings.
  2. In the observation interface. tap anywhere on the screen to enter the main menu. and tap “Settings” to enter other settings.
Temperature Gear
  • -20-150″C the image details are better in this gear, and the maximum temperature measured is 150’C.

  • 100-550″C: the image details are slightly worse in this gear and the maximum temperature measured is 550″C.

 Above/Below Alarm
  • Temperature alarm setting for M200A: set the above alarm or below the alarm
  • Auto alarm capture switch: click to turn on or turn off the auto alarm capture
  • Set the time interval for auto alarm capture
  • Set number of captured images for auto alarm capture
Wi-Fi Setting

Click and enter the WiFi setting interface.

  • Hotspot Switch: turn on the hotspot and set the network name and then click OK. Note:
  • A specialized app is needed while this function is enabled. You need to connect the hotspot manually after turning hotspot and you can transmit the saved pictures or videos to a mobile device to perform secondary analysis.
  • Turn off the hotspot when it is not or else the power consumption will be faster.
Set Image Capturing

Autosaving switch for manual image capturing: click to turn on or turn off the auto-saving function for manual image capturing. off by default.

The timed image capturing: click to turn on or turn off the function of timed image capturing

Set the time interval for timed image capturing

Set the number of captured images for timed image capturing

Automatic Power-off
  • 5Min: click to set automatically shut down after 5 minutes.
  • 10Min: click to set automatically shut down after 10 minutes.
  • 20Min: click to set automatically shut down after 10 minutes.
  • Off: click to turn off the automatic shutdown
Dual-spectrum Alignment
  • Dual-spectrum Fusion Alignment

This function can be used to manually align infrared and visible images. First select coarse tuning and fine-tuning. and then perform image alignment by the touch screen or navigation keys. After finished. Click the OK or enter button to save the settings.

Notes: the dual-spectrum alignment can be adjusted via the touch screen. the alignment can be achieved

by dragging the infrared image up-down or left-right with fingers.

  • Picture-in-picture Adjustment

This function can be used to adjust the position of the picture-in-picture. First, select coarse tuning and fine-tuning, and then adjust the position of the picture-in-picture by the touch screen or navigation keys. When finished. Click the OK or enter button to save the settings.

Notes: the PIP can be adjusted via the touch screen. press the infrared region to drag. press any corner of the infrared region to zoom in or zoom out

System Settings
  • Device Information
    Click to check the model. version. SD card capacity and SD card remaining capacity.

  • Date and Time
    Click to set the date and time.

  • Units of Measuremen t
    Temperature unit: switchable among Celsius. Fahrenheit. and Kelvin
    Distance unit: switchable between meters and feet

  • Formatting the SD Card
    Click and then press OK to format the SD card as FAT32.

  • USB Mode
    There are two options for data transmission: USB disk and USB camera.

  • Restore Factory Settings
    Click and then press OK to restore the settings to the factory settings.

Structural Drawings

Important Notices

To avoid damage to others and yourself, or your device. please read all the below information carefully prior to using this device.

  1. Please do not point to the Sun and another high-intensity radiation source directly.
  2. Ideal working temperature is-10t 50`C.
  3.  Do not touch the lens with your hands or other things.
  4. Do not touch the device with wet hands.
  5. Do not wipe and clean your device with diluent.
  6. Please do not wrongly connect the attached cables to avoid damage to the device.
  7. Please take care to avoid static electricity.
  8. Please do not disassemble the device. If there is any problem, please contact our company for professional maintenance.

Support and Service

 Technical Supports

System training can be carried out for users’ technical staff and operators. 7.2 After-sales Services

M200 series handheld thermal cameras. developed by our company. are guaranteed of good after-sales service for device maintenance and repair. If you have any requests. please contact us.

Company Information

Ray Technology Co., Ltd.
Website:www.infiray.com
Tel: 86-0535-3410623
Fax: 86-0535-3410610
Mail: sales@iraytek.com

Add: No.11 Guiyang Street. VEDA. Yantai. Shandong Province, P.R. China.

FCC Warning

$ 15.19 Labeling requirements.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

$  15.21 Information to the user.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

$  15.105 Information to the user.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.

Body-Support Operation

This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 0cm must be maintained between the user’s body and the handset, including the antenna. Third-party belt clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.

Worth comes from Service

24h Hotline: 400-998-3088

Technical Support Hotline:400-883-0800

Customized Services

Documents / Resources

| InfiRay M200 Series Handheld Thermal Camera [pdf] User Manual
M200A, 2AYGT-M200A, 2AYGTM200A, M200 Series Handheld Thermal Camera, Handheld Thermal Camera, Thermal Camera, Camera
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals