LURACO PSC-110 Pump Speed Control User Manual

June 6, 2024
LURACO

LURACO PSC-110 Pump Speed Control

LURACO PSC-110 Pump Speed Control

Safety Precautions

When using electrical equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  1. Read and follow all instructions before using the equipment.
  2. Keep the cord out of heavy traffic area. NEVER put the cord under rugs or near heat generating devices.
  3. Always unplug power before servicing.
  4. Do not drop or insert any object into any openings.
  5. Do not operate PSC if it is damaged.
  6. Any other use not recommended by the manufacturer may result in electrical shock or injury to persons.
  7. Never use outdoors.
  8. Do not attempt to repair or adjust any electrical or mechanical function on this unit. Doing so will void the warranty.

FEATURES – OPERATIONS

LURACO Pump Speed Control (PSC) -This system allows the user to electronically adjust the pump speed or jet pressure to desired level.
Other features:

  • Integrated water sensor
  • One extra outlet for LED light
  • Built in 20-minute timer
  • If the water sensor is installed, motor will not be turned on until water level is above the sensor electrodes.

(Note: There is a 10 second turn- off delay when water level goes below sensor)

Overall System Integration

INSTALLATION GUIDELURACO PSC-110 Pump Speed
Control-1

Installation Guide for the Water Level Sensor

Two conductive electrodes with advanced electronics and firmware are used to detect the water level. This is the same water level sensing technology that has been widely used in Bathtubs and Whirlpool tubs. This technology can work with any non-metallic spa tub materials, such as fiber glass, clear fiber glass, acrylic and even glass. A proper sensor installation is required. Important Note: if your tub is painted with metallic particles filled paint, you need to remove the paint surrounding the electrodes in order for the sensor to operate properly.LURACO PSC-110 Pump Speed
Control-2

Follow the steps below for the water level sensor installation. Choose the location for the sensor electrodes to be installed.
Note: The electrodes can be installed in vertical or horizontal configuration (Fig. 2b)

  • Drill two holes (9/64in diameter) on the tub with approximate distance as shown in Fig. 2b above. Insert the electrodes and tighten the nuts to secure the ring connectors as shown in Fig. 2a above.
  • Connect the other end of sensor cable to the PSC port named “Level Sensor”
  • Connect the control button to the PSC port named “Control Button”.
  • Connect the Light transformer to the PSC port named “Light” Note: The maximum current this port can provide is 1 A.
  • Connect the Pump to the PSC port named “Motor”

PSC SPECIFICATIONS

  • Ratings (Max): L1004B: Motor (up to 13.5 Amp), Light (1 Amp)
  • Voltage: 120VAC
  • Frequency: 60Hz
  • Dimensions: L: 5.9in, W: 3.1in, H: 5.31in
  • Weight: 3Lbs
  • This controller is not compatible with capacitor started motor

WARRANTY INFORMATION

ONE (1) YEAR LIMITED WARRANTY

  1. This Warranty applies only to the original purchaser of this product.
  2. This Warranty applies ONLY to repair or replacement of any supplied or manufactured parts of this product. The warranty does not cover normal wear, coating, dropped or abused units.
  3. Unless otherwise proscribed by law, LURACO shall not be liable for any personal injury, property or any incidental or consequential damages of any kind resulting from malfunctions, defects, misuse, improper installation or alteration of this product.

Attention: Any modification to the product will void the warranty

REPAIR AND SERVICE INSTRUCTIONS
If you need to send a unit to us for repair, please follow the steps below.

  1. A return must be coordinated with the store where the product was purchased for return authorization from Luraco Health & Beauty LLC.
  2. Carefully pack the item in its original carton, if available, or other suitable box to avoid damage in shipping
  3. Before packing your unit; be sure to enclose:
    • Your name with full shipping address and telephone number
    • A dated receipt to show PROOF OF PURCHASE
    • A note detailing the problem you are having with the unit

DISCLAIMERS

Limited warranty and liability — Information in this document is believed to be accurate and reliable. However, LURACO Health & Beauty, LLC does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information.
In no event shall LURACO Health & Beauty, LLC be liable for any indirect, incidental, punitive, special or consequential damages (including – without limitation – lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory.
Notwithstanding any damages that customer might incur for any reason whatsoever, LURACO Health & Beauty LLC’s aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of LURACO Health & Beauty LLC. Right to make changes — LURACO Health & Beauty, LLC reserves the right to make changes to the product and information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof.
Suitability for use — LURACO Health & Beauty, LLC products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or malfunction of an LURACO Health & Beauty, LLC’ product can reasonably be expected to result in personal injury, death or severe property or environmental damage.

LURACO HEALTH & BEAUTY, LLC
1140 107TH STREET
ARLINGTON, TX 76011
TEL: +1-817-633-1080 FAX: +1-817-631-085
WWW.LURACO.COM