keeler MBUNIV040 Vantage Plus Digital Ophthalmoscope Instructions
- June 6, 2024
- keeler
Table of Contents
keeler MBUNIV040 Vantage Plus Digital Ophthalmoscope
The Keeler Vantage Plus Digital is designed and built in conformity with
Directive 93/42/EEC, Regulation (EU) 2017/745 and ISO 13485 Medical Devices
Quality Management Systems.
Classification: CE: Class I
FDA: Class II
The information contained within this manual must not be reproduced in whole
or part without the manufacturer’s prior written approval. As part of our
policy for continued product development we the manufacturer reserve the right
to make changes to specifications and other information contained in this
document without prior notice.
This IFU is also available on the Keeler UK and Keeler USA websites.
Copyright © Keeler Limited 2021. Published in the UK 2021.
INTRODUCTION
The Keeler Vantage Plus Digital is an indirect ophthalmoscope that captures
images as seen by the user, primarily for teaching purposes.
Keeler does not recommend the use of the digital data for diagnostic purposes.
SAFETY
WARNINGS AND CAUTIONS
Please note that the proper and safe functioning of our instruments is only
guaranteed if both the instruments and their accessories are exclusively from
Keeler Ltd. The use of other accessories may result in increased
electromagnetic emissions or reduced electromagnetic immunity of the device
and may lead to incorrect operation.
Observe the following prescriptions in order to ensure safe operation of the
instrument.
- Do not modify the device.
- The camera should be connected to a PC compliant with Electrical Safety (Medical) EN/IEC 60601-1.
- NOTE: This instructions for use document must be read in conjunction with the instructions for use document (part number EP59-19017) for the Vantage Plus and Vantage Plus LED indirect ophthalmoscopes.
CONTRAINDICATION
Whilst BIO using a head mount can be performed through an undiluted pupil, the
fi eld of view and magnifi cation can be greatly compromised; therefore,
pupillary dilation using mydriatics is recommended in practice. Optometrists
regularly perform pupil dilation to comprehensively examine the ocular fundus
as part of a comprehensive eye health examination where clinically indicated.
Furthermore, in order to gain a more peripheral view of the retina, scleral
indentation is performed as an adjunct to BIO when using a head mount.
LIST OF CONTENTS
- Vantage Plus binocular indirect ophthalmoscope
- Vantage Plus instructions
- Software driver and application
- USB Cable (5m)
SET UP
Set up your Vantage Plus Digital as you would normally set up your indirect. The unit should be set up before starting examination procedures.
INSTALL THE SOFTWARE
Refer to Software Setup and Quick Start Guide – EP59-09871.
PLUG IN THE USB CABLE
When the software has been installed, plug in the cable to the mini USB port.
Plug in USB cable to your computer
CORRECT POSITIONING
Position on your head and adjust as you would during a normal examination.
ADJUST THE CAMERA PATCH
Adjust the camera patch on the screen by rotating the spindle.
ADJUST THE FOCUS LENS
Adjust the focus of the lens by rotating the focus adjusting lever.
WORKING DISTANCE
The working distance is variable from 300-600mm from the front of the
patient’s eye to the front of the instrument with a 20D lens.
If the image on the screen is out of focus you need to move the optics forwards and or backwards until it becomes in focus.
TURN OFF CAMERA
Unplug the USB cable to turn off the camera.
SPARE PARTS AND ACCESSORIES
Item | Part Number |
---|---|
Vantage Plus Digital Footswitch | 1205-P-7001 |
Binocular Indirect Face Shield | 1205-P-7034 |
Volk 20D Black Condensing Lens | 2105-K-1159 |
Vantage Plus Digital Carry Case | EP79-43643 / EP19-43108 |
PACKAGING AND DISPOSAL INFORMATION
Disposal of old electrical and electronic equipment
This symbol on the product or on its packaging and instructions indicates that
this product shall not be treated as household waste.
To reduce the environmental impact of WEEE (Waste Electrical Electronic
Equipment) and minimise the volume of WEEE entering landfills we encourage at
product end of life that this equipment is recycled and reused.
If you need more information on the collection reuse and recycling then please
contact B2B Compliance on 01691 676124 (+44 1691 676124). (UK only).
Any serious incident that has occurred in relation to the device must be
reported to the manufacturer and the competent authority of your Member State.
WARRANTY
The Keeler Vantage Plus Digital is guaranteed for three years against faulty workmanship materials or factory assembly. Warranty is on a Return To Base (RTB) basis at the cost of the customer and may be void if the Slit Lamp has not been regularly serviced.
The manufacturer’s warranty and terms and conditions are detailed on the
Keeler UK website.
The mirror, main illumination lamp and general ‘wear and tear’ are excluded
from our standard warranty.
The manufacturer declines any and all responsibility and warranty coverage should the instrument be tampered with in any manner or should routine maintenance be omitted or performed in manners not in accordance with these manufacturer’s instructions.
There are no user serviceable parts in this instrument. Any servicing or repairs should only be carried out by Keeler Ltd. or by suitably trained and authorised distributors. Service manuals will be available to authorised Keeler service centres and Keeler trained service personnel.
Contact
Manufacturer
Keeler Limited
Clewer Hill Road Windsor
Berkshire
SL4 4AA UK Freephone 0800 521251
Tel +44 (0) 1753 857177
Fax +44 (0) 1753 827145
USA Sales Office
Keeler USA
3222 Phoenixville Pike
Building #50
Malvern, PA 19355 USA
Toll Free 1 800 523 5620
Tel 1 610 353 4350
Fax 1 610 353 7814