AAF AstroPure 2000 Air Cleaner User Manual
Purpose of this Manual
DANGER:
Imminent danger that leads to severe physical injury or death
Before you operate the AstroPure air purifier for the first time or if you are entrusted with other work on the AstroPure air purifier, you must read the operating manual. The operating instructions help you to use the AstroPure air purifier as intended, properly, effectively and safely. Therefore, read the following chapters carefully and carefully. If necessary, always look up facts that are decisive for you. The operating instructions inform and warn you of residual risks against which a risk reduction through design and protective measures is not or not fully effective.
Target groups
Key User: Keep these instructions and other applicable documents available at the place of use of the system, also for later use.
User : encourage you to read and observe these instructions and the applicable documents, especially the safety and warning notices. Observe additional system related provisions and regulations.
Qualified maintenance personnel : Read, observe and follow these
instructions and other applicable documents, especially the safety and warning
notices.
Personnel qualification: A qualified person is understood to mean a person who
has successfully completed vocational training. He/She must assess the work
that has been assigned and be able to independently recognize and avoid
possible dangers based on her professional training and work experience.
Personnel for the maintenance and repair of ventilation devices and air
filters must be trained and instructed (for example according to VDI 6022-4).
WARNING:
Possibly dangerous situation that could lead to severe physical injury or
death
Delivery documents
The AstroPure air purifier is shipped with an
- installation, operation and maintenance manual,
- AAF HEPA filter test report.
For maintenance instructions the following documents from other supplier are supplied and must also be read and observed:
- Fan: type „E“ or „Z“
- LCD / PLC panel (optional)
- UV-C-Stage (optional)
Orientation in these operating instructions
These operating instructions contain the following general information symbols that guide you, the reader, through the operating instructions and give you important information.
Intended Use:
AstroPure air purifiers are designed exclusively to free normal room air from suspended particles and to return the purified air to the room. AstroPure air purifiers are intended as devices for installation exclusively in commercial and non-commercial interiors.
Foreseeable misuse:
AstroPure air purifiers must not be used for any other purpose. The following foreseeable misuse is not permitted:
- Extraction from an explosive atmosphere
- Use as a dust extraction system
- Use as a smoke extraction system
- The operation of the AstroPure air purifier with blocked air inlets and outlets
- Independent remodeling or repair work
- Operating the AstroPure air purifier without instruction or training
Any other use case requires written approval from AAF International.
ATTENTION:
Potentially dangerous situation that could lead to minor physical injuries.
NOTE:
Situation that can lead to possible property damage to the AstroPure air
purifier.
Safety
DANGER: ELECTRIC SHOCK
DANGER: NOISE The unencapsulated fan can generate sound emissions > 70dB (A) (with the maintenance door open). Damage or loss of hearing can result.
EAR PROTECTIONS Have device maintenance and repair carried out by qualified personnel only. Sufficient hearing protection must be worn during maintenance and repair work when the fan is running.
DANGER: CRUSHING HAZARD There is a risk of crushing when opening the maintenance door. This can result in bruising of the extremities. Have device maintenance and repair carried out by qualified personnel only
Operation may only be carried out after a instruction and training. Maintenance and repair may only be carried out by qualified personnel.
Observe the principles for the safe operation of electrical devices.
For maintenance and repair work, the accompanying documents for the supplier
components must be observed.
Hazard potential emanating from the AstroPure Air Cleaner.
Electric shock:
Electrical supply line can possibly be defective.
Under no circumstances use devices with a damaged electrical connection cable.
- Check the power cords before use.
- Damaged cables must be replaced immediately.
- Electric cables must never be exposed to water, heat or sharp objects.
- Do not move the device by pulling the power cord.
- Avoid running equipment and vehicles over power lines, or provide adequate protection for them.
- The device should be in the off mode to connect or disconnect the main power supply.
- Internal cabling (fan, control panel, UV-C stage) can be defective.
- Do not continue to operate devices with an internal error and, if possible, disconnect them from the power supply.
- Carry out maintenance and repair work only when the power supply is disconnected and the AstroPure air purifier is switched off.
Crushing Hazard:
Due to its own weight, there is a risk of crushing when transporting and moving the AstroPure air purifier.
This can result in bruising of the extremities.
The AstroPure air purifier must be moved with an appropriate method to avoid accidental injury or damage of any kind.
Preferred method is to use approved lifting gear and secured against unintentional lowering of the load:
- protect the forklift forks before lifting
- lift up slighty the AstroPure unit using the forklift and remove it from the wooden pallet
- put down the AstroPure unit using the forklift
Quick Start Guide (Potentiometer Control)
Quick start guide
-
Observe the safety instructions for safe operation
-
Ensure a safe stand on smooth, level, stable ground/floor
-
Lock the castor wheels
-
ON / OFF switch in OFF
-
Set the speed controller to the “OFF” position
-
Plug in the power plug
-
ON / OFF switch ON
-
Check serial number for fan type on the Type Plate on the back of the unit
Serial No. : E11-2020-12345 => “E”-type
Serial No. : Z11-2020-12345 => “Z”-type -
Rotate speed setting to desired air volume flow according to the table below
Yellow warning lights light up:
Filters must be changed by qualified personnel
- Note the date of first use
- Note down the operating time
- Observe and document change intervals for filters
Have the filter change and maintenance carried out by qualified personnel only
In the event of danger or malfunction:
Pull out the mains plug and have the device serviced by qualified personnel
**** Observe the protective instructions on the device. Secure the open maintenance door against unintentional closing.
DANGER: ROTATING DEVICE Fast rotating parts of the fan The high-speed impeller of the fan can injure body parts on contact. Have device maintenance and repair carried out by qualified personnel only
**** DANGER: CRUSHING HAZARD The device can tip over if lifted (excessively). This can result in bruising of the extremities. Do not tilt the device. Set up the device outside the area of movement of people.
DANGER: CRUSHING HAZARD Optional: The AstroPure air purifier is equipped with an additional UV-C stage. UV-C radiation bears the risk to cause severe damages to the eye and skin. The UV-C stage is not accessible during normal operation
Quick Start Guide (LCD / PLC Control)
Quick start guide
- Observe the safety instructions for safe operation
- Ensure a safe stand on smooth, level, stable ground
- Lock the castor wheels
- Plug in the power plug
- Switch the ON/OFF switch at the back side of the unit to ON-position
- Press the standby button to turn on the fan
- To unlock the screen, enter the password “116”
- Adjust volume flow rate to desired level by tapping on + (increase) or – (decrease)
General Information
The AstroPure air purifiers are designed to remove particles from normal dry room air, which is returned to the room after cleaning.
The installation conditions are:
- Installation indoors in a dry environment
- Moving and purification of dry indoor air
- Operating temperature range: 0 °C to 40 °C
- Air humidity rH. <90%, no condensable humidity
- Not approved for use in an explosive atmosphere
- Filter change as described in the maintenance instructions
- Carry out cleaning, maintenance and repair as specified in the maintenance instructions and in accordance with VDI6022
Type label
The Type label of the AstroPure air purifier shows the following characteristics (example below):
Image 1 : AstroPure type label
Technical characteristics
Parameter | Unit | AstroPure – 2000 |
---|---|---|
Nominal flow rate | m3 /h | 2000 |
Dimensions (WxLxH) | mm | 770x720x1628* |
Device weight | kg | 150* |
Min. ambient temperature | °C | 0 |
Max. ambient temperature | °C | 40 |
Allowed rel. humidity level | % | 0-90 |
depending on execution |
Connection details and power consumption
Connection details| | 1PH 230V 50 / 60Hz
Fan| kW| 0,5
UV-C stage| W| 25
Sound pressure level (SPL) at a distance of 1 m| Db(A)| 24-55
SFP| kW/m³/s| 0,513 (Fan type “E”) 0,452 (Fan type “Z”)
IP-class| | IP20
Maximum recommended pressure drop:
Pre filter| |
RedPleat| Pa| 250
RedPleat VF| Pa| 250
HEPA filter:| |
AstroCel III| Pa| 450
MEGACel I| Pa| 450
Table 1 : Technical parameter of AstroPure 2000 Air Cleaner
Accompanying guidelines and documents
The installation and use conditions are:
- AAF pre-filter Technical Data Sheet
- AAF HEPA filter Technical Data Sheet
- AAF Filter change out recommendations
- AAF filter storage recommendations
Technical details of fan and UV-C stage are relevant only to service / repair
personnel.
For the most current versions visit us at
www.aafeurope
Components
- The AstroPure air purifier (1) has the following main components:
- Swivel castors with locking device (2)
- Power plug (3) / LCD/PLC: Power plug with On/OFF switch at the back of the unit
- Air inlet (4)
- Air outlet (5)
- Fan (6)
- Pre-filter (7)
- HEPA filter (8)
- Optional UV-C stage (9)
- Control panel (10)
- The control unit consists of the following individual parts:
- ON / OFF switch (11)
- Operating status light device ON (12)
- Volume flow controller (13)
- Status display pre-filter (14)
- Status display HEPA filter (15)
- LCD panel (16)
Filter and consumables
The AstroPure air purifiers are equipped with the following filter stages:
- Pre-filter
- HEPA filter
- Optional: UV-C stage
Decommissioning in the event of maintenance
The device must be switched off and disconnected from the power supply for maintenance and repair.
Storage, transport and assembly
Storage
The storage conditions for the AstroPure air purifiers are:
- Storage in a dry, protected environment, if possible in the original packaging.
- Storage temperature range: -30 ° C to 40 ° C
Air humidity rH. <90%, no condensable humidity.
Unpacking
Remove the securing straps, stretch wrap, and card board packing material from the AstroPure 2000 Air Cleaner. Disposal of the packaging material must obey the local waste disposing regulations.
Castor rolls
Castor rolls are fastened on the bottom with bolts (M10, M13 wrench).
Transport
Only move heavy loads with suitable means of transport.
Installation of Air Inlet and Air Outlet ductwork (optional)
Installation of Air Inlet and Air Outlet ductwork needs to be carried out by qualified personnel only.
Installation area
The installation surface must be smooth and level and have sufficient load bearing capacity.
**** DANGER: CRUSHING HAZARD
WEAR SAFETY SHOES
**** Avoid hard knocks and jerky loads. Risk of filter damage. Secure the load against unintentional rolling away
Commissioning, Operation, Cleaning and Disposal
General
In case of any abnormal noises, sounds, and vibrations or in case of no
operational sounds (no fan sound), turn the AstroPure Air Cleaner off,
disconnect it from the power supply and have the equipment inspected by
trained personnel.
Maintenance work must be carried out by qualified personnel only according to the instructions by AAF as well as the personnel for the maintenance and repair of ventilation devices and air filters must be trained and instructed (e.g. according to VDI 6022-4). Personal protective equipment (gloves, respirator, eye protection) must be worn during maintenance work inside the device and when changing the air filter.
Control panel Potentiometer Control
-
Potentiometer Control
-
LCD / PLC Control
Image 5 AstroPure Control Panel
The control unit consists of the following individual parts:
Potentiometer Control:
- ON/OFF switch (11)
- Operating status light device ON (12)
- Volume flow controller (13)
- Status display pre-filter (14)
- Status display HEPA filter (15)
LCD / PLC
- ON/OFF switch at the back of the unit (3)
- Touch sensitive display (16)
- Indicators signaling the need for filter servicing
Initial start-up
The AstroPure air purifiers are delivered ready for use.
Perform the following work steps for initial commissioning:
Remove packaging and dispose of properly in accordance with local waste
regulations.
The AstroPure air purifiers are equipped with four swivel castors for easy
maneuverability.
- Make sure that all four swivel castors have good contact with the installation surface and, if necessary, enable this by repositioning the device.
- Make sure that the maintenance door of the device is properly closed.
- Make sure that the air inlet and outlet openings are freely accessible and not obstructed or occupied.
- Fix the locking devices of the castors.
Filters
The following filter options are installed:
Type | Style Code | |
---|---|---|
Pre-filter (7) | RedPleat | ISO Coarse 70% |
RedPleat | ISO ePM10 70% | |
RedPleat CF | ISO Coarse 65% | |
HEPA filter (8) | MEGACel I | H14 |
ASTROCEL III | H14 |
Operation (Potentiometer Control)
- Make sure the ON / OFF switch is in the OFF position.
- Set the volume flow controller / speed controller to a middle position.
- Plug in the power plug.
- Set the ON / OFF switch to ON.
Set the desired volume flow.
- Keep a sufficient distance from the outflow openings.
- The volume flow can be regulated continuously between minimum (25% maximum volume flow) and maximum volume flow.
- Set the desired volume flow.
- Set the desired volume flow by turning the rotary knob according to set points given in the table “Quick Start Guide (Potentiometer Control)
Operation (LCD / PLC Control)
- Plug in the power plug
- Set the ON/OFF switch at the back side of the unit to ON.
Set the desired volume flow.
- Press the standby button to turn on the fan
- To unlock the screen, enter the password “116”
- Volume flow adjustment:
- Method (1)
- Press the flow rate bar to set the initial value. The exact desired speed of the fan can be set here.
- Press the plus and minus button. The respective speed increment is set in the configuration menu.
- Method (2)
- Press an area on the flow rate bar. With this option, the speed of the fan is set to one of the 4 parameter values at a time (25% steps).
- Information on display:
Service: filters must be changed by qualified personnel
AstroPure 2000 LCD
To access the user menu (to unlock the display), the user can press the
‘AstroPur’ logo or, alternatively, press the lock symbol for 2 seconds.
The user menu password is “116”.
Main User Menu
Press the AstroPure logo for 3 seconds.
The language settings can be modified and system information can be viewed (software version, hardware ID).
After 60 seconds of inactivity, the main screen will automatically ‘lock’, viz. no changes can be made to any settings, e.g., main standby switch on/off, airflow set point, lamp on/off, etc.
To modify any setting, the screen needs to be unlocked again.
After 60 seconds of inactivity, the main screen will automatically ‘lock’, viz. no changes can be made to any settings, e.g., main standby switch on/off, airflow set point, lamp on/off, etc.
To modify any setting, the screen needs to be unlocked again.
Configuration menu, language and system information
Press the AAF-logo field for 5 seconds to enter the configuration menus.
Enter the password “-1101“.
The controller‘s parameters can be changed here.
Resetting of operating hours
In the configuration menu, these values can be reset by pressing the corresponding button for 5 seconds.
Appropriate flow rate
To achieve best air cleaning results, the air cleaners flow rate must be adjusted to the individual situation of the designated room.
Following calculation steps provide a basic guide line:
- The volume of the designated room in cubic meters (m³) is calculated by multiplying the room’s length width height in meters: V = L W H
- The desired number of room air exchanges per hour (ACH) has to be selected (units: 1 /h). This number is sometimes also referred to as air exchange rate.
When this value is not preset, the following ACH values represent the currently applied recommendations:
-
Good ventilation: ACH = 4 1/h
-
Excellent ventilation: ACH = 6 1/h
-
Purging of rooms: ACH = 10 1/h
The necessary air flow rate is then determined by multiplying the room’s volume V with the desired air exchanges per hour. -
Necessary flow rate = V * ACH
Example
- A room has the dimensions of (L W H) = 5 m 8 m 3 m
- The volume is calculated to 5 m 8 m 3 m = 120 m³.
- The desired air exchange rate is ACH = 4 1/h
- The air cleaner has to deliver 4 1/h * 120 m³ = 480 m³/h.
The table below serves for guidance.
Parameter| Symbol| Unit| Example 1| Example 2|
Example 3| Example 4
---|---|---|---|---|---|---
Length| L| m| 10| 10| 10| 10
Width| w| m| 10| 10| 10| 10
Height| H| m| 2| 2.5| 2.5| 2.5
Volume| V| m3| 200| 250| 250| 250
Air exchanges per hour| ACH| 1h| 4| 4| 6| 8
Required air volume flow| | m i/h| 800| 1.000| 1.500| 2.000
Cleaning of the external surface
Always disconnect the AstoPure Air Cleaner from the power connection when cleaning it. The surface of the device can be cleaned with common mild soap based household cleaning detergents only
Disposal
Spent filters should be packed in sealed plastic bags individually and
disposed off in accordance with local waste regulations.
Decommissioned electric and electronic equipment must be returned to approved
collection points in accordance to the local waste regulations.
Inspection and maintenance per component
The device components and filters must be checked for function and wear at regular intervals and serviced, at least after the periods specified below or earlier if necessary
Inspection Intervals
Pre filter:| months| 3
HEPA filter:| months| 3
UV-C Stage| months| 3
Maintenance door| months| 6
Moving parts| months| 6
Fan section| months| 6
Entire unit| months| Prior to each use and very 12 months
Replacement Intervals
Pre filter:| months| 3
Red Pleat| months| 6
RedPleat CF| months| 6
HEPA Filter
AstroCel III| months| 12
MEGAcel I| months| 12
UV-C Stage| hours| 9.000
Emergency
If possible, disconnect the AstroPure air purifier from the power supply by pulling the plug. If it is not possible to pull out the mains plug safely, the power supply must be interrupted by disconnecting it from the building circuit (safety switch)
Fire fighting
In the event of a fire, fight it with extinguishing agents approved for electrical appliances. Dangerous substances escape in the event of fire. In the event of a fire, do not breathe the fumes and smoke that may be produced. After ensuring that the extinguishing is complete, ensure that the rooms are adequately ventilated.
Drawings and diagrams
The overall dimensions the installation dimensions of the AstroPure 2000 Air Cleaner are:
Wiring diagram
The wiring diagram for the AstroPure Air Cleaner can be found in the appendix.
Serial number and fan type
The AstroPure 2000 is equipped with either fan type “E” or fan type “Z”, which can be identified from the unit’s serial number (example on the left).
Fan calibration curves
Spare parts
The following filter options are to be used when replacing filters:
Type | Style code | Part number | WxHxL (mm) | |
---|---|---|---|---|
Pre-filter (7) | RedPleat | RP-4470-05920592045-CS00Z | 555001210 (4531002424) |
592 x 592 x 45
RedPleat| RP-5370-05920592045-CS02Z| 555004102 (4151002424)| 592 x 592 x 45
RedPleat CF| RPCF-0465-05920592045-CS0Z| 555000951 (4139002424)| 592 x 592 x
45
HEPA filter (8)| MEGACel I| MEGA I.eFRM.H14.610x610x292| (295099013)| 610 x
610 x 292
ASTROCEL III| ASTROCEL III AP A39A05C9S2R0| 555004088 (1493299990)| 610 x 610
x 292
UV-C lamp (9)| PHILLIPS| TUV 25W 1Sl/25| (BR00000777)|
Certificates and Protocols:
The unit complies to European directives and standards with European
Directives and bears the CE marking. The unit is checked for tightness of the
installed filters and a leak test certificate is issued. The HEPA filter has
an individual test certificate which is included in the
Air Cleaner’s accompanying documents or supplied with each replacement HEPA
filter.
Manufacturer’s Declaration of Conformity
The AAF AstroPure Air Cleaners are manufactured in compliance with applicable
international regulations and standards by
AAF Lufttechnik GmbH Odenwaldstrasse 4 D-64646 Heppenheim Germany
Telefon: +49 (0)6252 69977-0
Email: Sales.DACH@aafeurope.com
A risk assessment and compliance evaluation procedure has bend conducted referenced on the following certification procedures according to the assessment as in: Machine directive 2006/42/EC, Directive on eco design EC 2009/125. Following standards and guidelines were used for the assessment of the equipment’s compliance:
Following standards and guidelines were used for the assessment of the equipment’s compliance
- 2006/42/EC Machine Directive
- 2014/30/EC Electromagnetic Compatibility (EMC) Directive
- 2014/35/EC Low Voltage Directive (LVD)
- 2009/125/EC ERP Energy conservation
- 1253/2014EC ERP implementation, 2018
- EN ISO 12100 General principles for design – Risk assessment and fire reduction
- EN ISO 13857 Safety of machinery – Safety distances to prevent hazard zones being reached by upper and lower limbs
- DIN EN 60335-1 Safety of electrical devices for household use and similar purposes – Part 1: General requirements
- VDI 6022-2018 Hygiene requirements for ventilation and air-conditioning systems and units – Design and construction and materials
The AAF AstroPure Air Cleaner are in full compliance with the above mentioned directives, standards and guidelines. A technical documentation of the risk and the compliance assessment is available on request from the manufacturer. Heppenheim, November 2020.
PAT Ruiter
Director Filtration technology
Heppenheim, November 2020
Declaration of Conformity
Manufacturer
-
Company name: AAF International
European Headquarters -
Full address: Odenwaldstral3e 4 D-64646 Heppenheim
-
Country: Germany
UK Authorised Representative
Which is established in the United Kingdom and has access to the Technical
File
Company name : Air Filters Ltd
Full address : Bassington Lane
Postal code : NE23 8AF
Place: Cramlington, Northumberland
Country: United Kingdom
Object of the declaration
Product: AstroPure 2000
Function: Air Cleaner
The object of the declaration described above is in conformity with the relevant UK Statutory Instruments (and their amendments)
2008 No. 1597 Supply of Machinery (Safety) Regulations
2008 2016 No. 1101 Electrical Equipment (Safety) Regulations
2016 2016 No. 1091 Electromagnetic Compatibility Regulations
2016 2012 No. 3032 The Restriction of the Use of Certain Hazardous Substances
in Electrical and Electronic Equipment Regulations 2012
References to the relevant designated standards used or references to the other technical specifications in relation to which conformity is declared: 85 EN ISO 121002010; 85 EN ISO 13857:2019; BS STN EN 60204-1; VDI 6022-2018
Technical documentation for the product Is available from:
Name: Air Filters Ltd
Full address: Bassington Lane NE23 8AF Cramlington, Northumberland United
Kingdom
Signed for and on behalf of:
Place of issue : Amsterdam, The Netherlands
Date of issue : April 6, 2021
Name: Peter ruiter
Director of filtration technology
Function:
Signature:
Appendix
LCD Control Potentiometer Control
Potentiometer Control
AAF Sales Offices
Dinair Finland
Dinair Clean Air, Oy
Koivuvaarankuja 2,
01640 Vantaa
Phone: +358 10 3222610
E-mail: cleanair@dinair.fi
France
AAF S.A.
9, Avenue de Paris
94300 Vincennes
Phone: +33 143 984 223
Fax: +33 158 641 142
E-mail: sales.france@aafeurope.com
Germany & Austria
AAF-Lufttechnik GmbH
Odenwaldstrasse 4
64646 Heppenheim
Phone: +49 (0)6252 69977-0
E-mail: sales.DACH@aafeurope.com
Dinair Latvia
Dinair Filton SIA
Rupnicu Street 4
Olaine, Latvia, LV-2114
Phone: +371 67069823
Dinair Denmark
AAF/Dinair APS
Vallensbækvej 63.1
2625 Vallensbæk
Phone: +45 70260166
E-mail: sales.denmark@aafeurope.com
Great Britain and Ireland
Air Filters Ltd (AAF International)
Bassington Lane, Cramlington
Northumberland NE23 8AF
Phone: +44 1670 591 790
Fax: +44 1670 590 262
E-mail: airfilter@aafeurope.com
Greece
AAF-Environmental Control Epe
1 Ifaistou & Kikladon
15354 Glika Nera
Phone: +30 210 663 20 15
Fax: +30 210 663 51 09
E-mail: greece@aafeurope.com
Italy
AAF S.r.l.
Via Friuli, 28/30
21047, Saronno (VA)
Phone: +39 02.9624096
Fax: +39 02.9606409
E-mail: sales.italy@aafeurope.com
Dinair Norway
Dinair AS
Prof Birkelands vei 36
1081 Oslo
Phone: +47 22 90 59 00
Fax: +47 22 90 59 09
Slovakia & Eastern Europe
AAF International s.r.o.
Bratislavska 517
91105, Trencin, Slovakia
Phone: +421 32/746 17 14
www.aafintl.com
Spain & Portugal
AAF S.A.
Vidrieros, 10
28830 San Fernando de Henares
Madrid, Spain
Phone: +34 916 624 866
Fax: +34 916 624 275
E-mail: info@aaf.es
Dinair Sweden
Dinair AB
Hamngatan 5
SE-592 30 Vadstena
Phone: +46 (0)143-125 80
Fax: +46 (0)143-125 81
The Netherlands
AAF Verkoop Nederland
Boerdijk 29A
7844 TB Veenoord
Phone: +31 (0)591 66 44 66
E-mail: aaf.verkoop@aafeurope.com
AAF International
European Headquarters
Odenwaldstrasse 4, 64646 Heppenheim
Tel: +49 (0)6252 69977-0
aafintl.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>