VOLT VFL 451X LI ABZ 120V LED Flood Light with Knuckle
INSTALLATION INSTRUCTIONS
VOLT® Line Voltage Landscape Lighting
VOLT® 120V LED Flood Light with Knuckle
VFL-451X-LI-ABZ
**** Important: Please Read Before Installation
- This LED floodlight uses the latest in solid-state lighting technology for long life, low maintenance, and high efficiency.
- An internal power-factor-corrected switch mode supply allows this fixture to be used from any nominal 90V-277VAC, 60Hz supply without any variation in light output.
- Suitable for use in: a. Ambient Temperatures of: -20~+45°C (-4~+113°F) a. Wet Locations
- INSTALLATION OR ASSEMBLY INSTRUCTIONS.
Note: Save these instructions for future reference.
**** Important Safety Instructions
To avoid the risk of fire, explosion, or electric shock, this product should
be installed, inspected, and maintained by a qualified electrician only, in
accordance with all applicable electrical codes.
To avoid electric shock:
- Be certain electrical power is OFF before and during installation and maintenance.
- The luminaire must be connected to a wiring system with an equipment grounding conductor.
To avoid explosion:
- Make sure the supply voltage is the same as the rated luminaire voltage.
- Do not install where the marked operating temperatures exceed the ignition temperature of the hazardous atmosphere.
- Do not operate in ambient temperatures above those indicated on the luminaire.
For supply connections use wire rated for at least 90°C (194°F)
Warning: These luminaires should ONLY be installed by a qualified electrician.
www.voltlighting.com
Package Contents
A. (1) Fixture body
Parts Required
A. (1) Mounting Accessory (Sold Separately)
Products Model
Model No. | Input Voltage (VAC) | Frequency (Hz) | Input Current (A) | Power (W) |
---|---|---|---|---|
10W Flood Light | 90-277 | 60 | 0.25 | 10 |
30W Flood Light | 90-277 | 60 | 0.75 | 30 |
50W Flood Light | 90-277 | 60 | 1 | 50 |
Product Dimensions
Two installation methods are provided for this fixture:
Surface Mount- Page 5
Stake Mount- Page 6
Option 1: Surface Mount
Install Surface Mount to Fixture body
Pass supply cable through the center hole of the surface mount. Then thread the surface mount onto the fixture body. Make sure the wire exit on the surface mount and the glare guard are in the opposite direction after installation.
Install Fixture Body to Mounting Surface
Place the supply cable in the wire exit. Then attach the surface mount with
the fixture body to the mounting surface and secure it with self-tapping
screws using a screwdriver to tighten.
NOTE: Wall anchors are required for brick walls or concrete walls. To
determine anchor locations, place the surface mount onto your desired location
and mark points using the hole on the surface mount as a guide.
Go to Step 3 – Step 4 for wiring connections and direction adjustment.
Option 2: Stake Mount
Install Stake
Determine the desired location for mounting the stake. Hammer the stake into
the ground until the flange of stake is flush to grade. To avoid damage to the
stake, place a board on top of the stake while hammering.
Note: If the ground is hard and the stake is difficult to install, make a
crosscut in the ground using a flat shovel.
Install Fixture Body to Stake
Pass the supply wires through the center hole of the stake and thread the
fixture body onto the stake. Hand tightens until snug. Clear away an area in
the ground and lay the supply wires into the stake’s wire exit.
Go to Step 3 – Step 4 for wiring connections and direction adjustment.
Wire Connections
By using the Allen wrench, unlock screws and remove the cover from the hub
body.
Insert the main supply cable, fixture supply cable, other fixture supply cable
or next hub supply cable into the hub body from the different conduit. Strip
both ends of supply cables. Insert the ends of neutral wires into the
“NEUTRAL” block. Insert the ends of line wires into the “HOT” block. Insert
the ends of ground wires into the “GROUND” block. Push each wire into place.
Place the cover back onto the hub body and secure it with previously removed
screws. Hand tightens until snug with Allen wrench.
Adjust Fixture Body Direction
Using the Allen wrench, unscrew the screw on the knuckle and adjust the fixture body to your desired direction. Once the desired direction is achieved, tighten the knuckle down with the Allen wrench.
Help Hotline:
1-813-978-3700
Mon-Fri 8am-8pm
Sat-Sun 10am – 6pm (EST)
www.voltlighting.com
Specifications and product details are subject to change without notice.
© Copyright 2021, VOLT®
Lighting, Lutz FL USA 33549
All rights reserved.
customersupport@voltlighting.com
813.978.3700
IS-VFL-451X-LI-ABZ-ver1.pdf
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>