DoorProtect User Manual
Updated March 26, 2021
DoorProtect is a wireless door and window opening detector designed for indoor use. It can operate up to 7 years from a pre-installed battery and is capable to detect more than one million openings. DoorProtect has a socket for connecting an external detector.
The functional element of DoorProtect is a sealed contact reed relay. It consists of ferromagnetic contacts placed in a bulb that form a continuous circuit under the effect of a constant magnet.
DoorProtect operates within the Ajax security system, connecting via the protected Jeweller radio protocol. The communication range is up to 1,200 m in the line of sight. Using the cartridge or Oxbridge Plus integration modules, DoorProtect can be used as part of third-party security systems. The detector is set up via Ajax apps for iOS, Android, macOS, and Windows. The app notes user of all events through push not cations, SMS, and calls (if activated).
The Ajax security system is self-sustaining, but the user can connect it to
the central monitoring station of a private security company.
Buy opening detector DoorProtect
Functional Elements
- DoorProtect
- Big magnet (should be placed to the right of the detector)
- Small magnet (should be placed to the right of the detector)
- LED indicator
- SmartBracket attachment panel (perforated part is required for actuating the tamper in case of any attempt to dismantle the detector. Don’t break it out!)
- External detector connection socket
- QR code
- Device switch
- Tamper button
Operating Principle
DoorProtect consists of two parts: the detector with a sealed contact reed
relay, and the constant magnet. Attach the detector to the door frame, while
the magnet can be attached to the moving wing or sliding part of the door. If
the sealed contact reed relay is within the coverage area of the magnetic eld,
it closes the circuit, which means that the detector is closed. The opening of
the door pushes out the magnet from the sealed contact reed relay and opens
the circuit. In such a way, the detector recognizes the opening.
Attach the magnet to the RIGHT of the detector.
A small magnet works at a distance of 1 cm, and the big one — up to 2 cm.
After actuation, DoorProtect immediately transmits the alarm signal to the
hub, activating the sirens and notifying the user and security company.
Pairing the Detector
Before starting pairing:
- Following the hub instruction recommendations, install the Ajax app on your smartphone. Create an account, add the hub to the app, and create at least one room.
- Switch on the hub and check the internet connection (via Ethernet cable and/or GSM network).
- Make sure that the hub is disarmed and does not update by checking its status in the app.
Only users with administrator rights can add the device to the hub.
How to pair the detector with the hub:
- Select the Add Device option in the Ajax app.
- Name the device, scan/write manually the QR Code (located on the body and packaging), and select the location room.
- Select Add — the countdown will begin.
- Switch on the device.
For detection and pairing to occur, the detector should be located within the coverage area of the wireless network of the hub (at the same facility).
The request for connection to the hub is transmitted for a short period of
time at the moment of switching on the device.
If pairing with the hub failed, switch off the detector for 5 seconds and
retry it.
If the detector has paired with the hub, it will appear in the list of devices
in the Ajax app. The update of the detector’s statuses in the list depends on
the detector ping interval set in the hub settings. The default value is 36
seconds.
Connecting to Third-Party Systems
To connect the detector to a third-party security central unit using the cartridge or Oxbridge Plus integration modules, follow the recommendations in the user manual of the respective device.
States
- Devices
- DoorProtect
Parameter | Value |
---|---|
Temperature | The temperature of the detector. The temperature is measured on |
the processor and changes gradually
Jeweler Signal Strength| The signal strength between the hub and the detector
Battery Charge| Battery level of the device. Displayed as a percentage How
battery charge is displayed in Ajax apps
Lid| The tamper state, which reacts to detachment or damaging of the detector
body
Delay When Entering, sec| The delay time when entering
Delay When Leaving, sec| The delay time when exiting
Rex| Indicates if the detector is routed through a radio signal range extender
Connection| The connection status between the hub and the detector
Primary Detector| The primary detector status
External Contact| The status of the external detector connected to DoorProtect
Always Active| If active, the detector is always in the armed mode
Temporary Deactivation| Shows the status of the device temporary deactivation
function:
No — the device operates normally and transmits all events.
Lid only — the hub administrator has disabled noti the device body.
Entirely — the device is completely excluded from the system operation by the
hub administrator. The device does not follow system commands and does not
report alarms or other events.
By a number of alarms — the device is automatically disabled by the system
when the number of alarms is exceeded (speci in the settings for Devices Auto
Deactivation). The feature is coned in the Ajax PRO app.
By timer — the device is automatically disabled by the system when the
recovery timer expires (speci Devices Auto Deactivation). The feature is coned
in the Ajax PRO app.
Firmware| The detector e version
Device ID| The device identi
Setting Up
- Devices
- DoorProtect
- Settings
Setting | Value |
---|---|
First | The detector name can be edited |
Room | Selecting the virtual room to which the device is assigned |
Delay When Entering, sec | Setting the delay time on exit |
Delay When Leaving, sec | Delay turned on when using night mode |
Delays in Night Mode | If active, the detector will switch to the armed mode |
when using the night mode
Arm in Night Mode| Allows you to disable the indicator during an alarm.
Available for devices with eversion 5.55.0.0 or higher
How to e-version or the ID of the detector or device?
Alarm LED indication| If active, DoorProtect primarily reacts to
opening/closing
Primary Detector| If active, the detector registers external detector alarms
External contact| If active, the detector always registers opening/closing
Always active| If active, added to the system are sirens activated when the
opening detected
Alert with a siren if opening detected| If active, added to the system are
sirens activated during an external detector alarm
Activate the siren if an external contact opened| Switches the detector to the
signal strength test mode
Jeweler Signal Strength Test| Switches the detector to the detection area test
Detection Zone Test| Switches the detector to the signal attenuation test mode
(available for detectors with eversion 3.50 and later)
Attenuation Test| Allows the user to disconnect the device without removing it
from the system.
Temporary Deactivation| Two options are available:
Entirely — the device will not execute system commands or participate in
automation scenarios, and the system will ignore device alarms and other noti
Lid only — the system will ignore only noti device tamper button Learn more
about temporary deactivation of devices The system can also automatically
deactivate devices when the set number of alarms is exceeded or when the
recovery timer expires. Learn more about auto
deactivation of devices
User Guide| Opens the detector User Guide
Unpair Device| Disconnects the detector from the hub and deletes its settings
Indication
Event | Indication | Note |
---|---|---|
First | Lights up green for about one Second | |
Detector connecting to the and hub Oxbridge Plus cartridge | Lights up for a | |
few seconds | ||
Alarm / tamper activation | Lights up green for about one second | Alarm is sent |
once in 5 seconds
Battery needs replacing| During the alarm, it slowly lights up green and
slowly goes out| Replacement of the detector the battery is described in the
Battery Replacement manual
Functionality Testing
The Ajax security system allows conducting tests for checking the
functionality of connected devices.
The tests do not start immediately but within 36 seconds by default. The
starting time depends on the ping interval (the paragraph on “Jeweller”
settings in hub settings).
Jeweller Signal Strength Test
Detection Zone Test
Attenuation Test
Installing the Detector
S electing the location
Location of DoorProtect is determined by its remoteness from the hub and
presence of any obstacles between the devices hindering the radio signal
transmission: walls, inserted ge objects located within the room.
The device was developed only for indoor use.
Check the signal level at the installation location
If the signal level is low (one bar), we cannot guarantee the stable operation
of the security system. Take all possible measures to improve the quality of
the signal! As a minimum, move the device — even a 20 cm shift can signiove
the quality of the reception.
If, after moving, the device still has a low or unstable signal strength, use
the.
ReX radio signal range extender
The detector is located either inside or outside of the doorcase (window
frame).
When installing the detector in the perpendicular planes (inside the
case/frame), use the small magnet. The distance between the magnet and
detector should not exceed 1 cm.
When positioning the parts of DoorProtect in the same plane, use the big
magnet. Its actuation threshold — 2 cm.
Attach the magnet to the moving part of the door (window) to the right of the
detector. The side to which the magnet should be attached is marked with an
arrow on the detector’s body. If necessary, the detector may be positioned
horizontally.
Installing the detector
Before installing the detector, make sure that you have selected the optimal location and it complies with the guidelines of this manual!
-
Fix the SmartBracket attachment panels and the magnet using the bundled screws. If using any other attachment hardware, make sure that they do not damage or deform the panel.
Double-sided adhesive tape may be only used for temporary attachment. The tape will run dry in the course of time, which may result in the falling of DoorProtect and the actuation of the security system. Furthermore, the device may fail from a hit. -
Put the detector on the attachment panel. As soon as the detector is ed in SmartBracket, it will blink with a LED signaling that the tamper is closed.
If the light indicator does not blink after installing in SmartBracket, check the status of the tamper in the Ajax app and then the If the detector is torn off from the surface or removed from the attachment panel, you will receive a noti -
Put the magnet on the attachment panel.
Do not install the detector:
- outside the premises (outdoors);
- nearby any metal objects or mirrors causing attenuation or interference of the signal;
- inside any premises with the temperature and humidity beyond the permissible limits;
- closer than 1 m to the hub.
Connecting a Third-Party Wired Detector
A wired detector with the NC contact type can be connected to DoorProtect using the outside-mounted terminal clamp.
We recommend installing a wired detector at a distance not exceeding 1 meter —
increasing the wire length will increase the risk of its damage and reduce the
quality of communication between the detectors.
To lead out the wire from the detector body, break out the plug:
If the external detector is actuated, you will receive a noti
Detector Maintenance and Battery Replacement
Check the operational capability of the DoorProtect detector on a regular
basis.
Clean the detector body from dust, spider web and other contaminations as they
appear. Use soft dry napkin suitable for equipment maintenance.
Do not use any substances containing alcohol, acetone, gasoline and other
active solvents for cleaning the detector.
The battery lifetime depends on battery quality, actuation frequency of the
detector and ping interval of the detectors by the hub.
If the door opens 10 times a day and the ping interval is 60 seconds, then
DoorProtect will operate up to 7 years from the pre-installed battery. Setting
the ping interval of 12 seconds, you will reduce the battery life to 2 years.
How long Ajax devices operate on batteries, and what affects this If the
detector battery is discharged, you will receive a noti will smoothly light up
and go out, if the detector or tamper is actuated.
Battery Replacement
Tech specs
Sensor | Sealed contact reed relay |
---|---|
Detector actuation threshold | 1 cm (small magnet) |
2 cm (big magnet)
Tamper protection| Yes
Socket for connecting wire detectors| Yes, NC
Frequency band| 868.0 – 868.6 MHz or 868.7 – 869.2 MHz depending on the region
of sale
Compatibility| Operates with all Ajax , hubs range, , extenders Oxbridge Plus
cartridge
Maximum RF output power| Up to 20 mW
Modulation| GFSK
Radio signal range| Up to 1,200 m (any obstacles absent)
Power supply| 1 battery CR123A, 3 V
Battery life| Up to 7 years
Installation method| Indoors
Protection class| IP50
Operating temperature range| From -10°С to +40°С
Operating humidity| Up to 75%
Dimensions| Ø 20 × 90 mm
Weight| 29 g
Certification| Security Grade 2, Environmental Class II in conformity with the
requirements of EN 501311, EN 50131-2-6, EN 50131-5-3
Complete Set
- DoorProtect
- SmartBracket mounting panel
- Battery CR123A (pre-installed)
- Big magnet
- Small magnet
- Outside-mounted terminal clamp
- Installation kit
- Quick Start Guide
Warranty
Warranty for the “AJAX SYSTEMS MANUFACTURING” LIMITED LIABILITY COMPANY
products is valid for 2 years after the purchase and does not apply to the
pre-installed battery.
If the device does not work correctly, you should service — in half of the
cases, technical issues can be solved remotely!
The full text of the warranty
User Agreement
Technical support: support@ajax.systems
References
- End user agreement - Ajax Systems
- All Ajax security system devices and detectors
- All Ajax security system devices and detectors
- All Ajax security system devices and detectors
- DoorProtect — Wireless magnetic opening detector | Ajax Systems
- uartBridge — Module for Ajax devices integration with third-party wireless alarms systems
- Software | Ajax Systems
- Warranty - Ajax Systems
- How battery charge is displayed in Ajax apps | Ajax Systems Support
- What is Devices Auto Deactivation and how it works | Ajax Systems Support
- How to find out the device firmware version | Ajax Systems Support
- How long Ajax devices operate on batteries, and what affects this | Ajax Systems Support
- How to deactivate a device without removing it from the system | Ajax Systems Support
- How to change the batteries in the DoorProtect | Ajax Systems Support
- What is Signal Attenuation Test | Ajax Systems Support
- What is Detection Zone Test | Ajax Systems Support
- What is Jeweller Signal Strength Test | Ajax Systems Support