inovonics EN1266 360° Ceiling Mount Motion Detector User Manual

June 6, 2024
Inovonics

inovonics EN1266 360° Ceiling Mount Motion Detector User Manual
inovonics EN1266 360° Ceiling Mount Motion Detector

Overview

The EN1266 360° ceiling mount motion detector is a four-element passive infrared intrusion detector for use in electronic security systems in ceiling mount applications. The EN1266 reduces false alarms to a minimal level due to its elimination of background noises and nuisance stimuli, employs automatic pulse count to make it adaptable to various environments, and uses sophisticated signal processing to make it virtually free of false alarms. The lens provides wide coverage patterns, even at low mounting heights, and is especially immune to sunlight, as well as halogen and fluorescent lights.

Inovonics Contact Information

 For product and installation videos visit us at www.inovonics.com/videos or use the QR code below.
QR Code

If you have any problems with this procedure, contact Inovonics technical support:

Installation and Startup

Installation Notes

  • These products are designed to be installed and maintained by professional security technicians.
  • Products are tested for indoor use.
  • All products should be manually tested weekly.

Install the Batteries

The EN1266 can accommodate two batteries for extra battery life, but only
one is required for operation.

Note: When installing batteries, it is recommended that batteries are replaced in new pairs from the same manufacturer.

To install batteries:

  1. Remove the housing cover from the base.

Figure 1 Remove the housing cover.

  1. Install the batteries included with the unit.

Figure 2 Install the batteries

Select Pulse Count

The pulse count options provides control for difficult operating environments. Automatic pulse count is recommended for reliable operation in environments subject to temperature fluctuation that can cause false alarms. The single pulse count mode is more sensitive to minor temperature variations, and should be used in sites where variant heat sources will not cause alarms. Automatic pulse count is the factory default because it allows more reliable operation in environments subject to temperature fluctuation. To select pulse count:

  1. Press the tamper button five times within three seconds.

Figure 3 Press the tamper button

  1. Wait for the green LED to blink five times, then:

    • Press the tamper button one time within three seconds to select single pulse count.
    • Press the tamper button two times within three seconds to select
      automatic pulse count.
  2. Confirm your selection.

    • The green LED will blink once to indicate single pulse count has been
      selected; twice to confirm automatic pulse count has been selected.

Select Fixed/Variable Sleep Time

The sleep time jumper setting provides control for normal or high-traffic
operating environments. When set to fixed, if the EN1266 senses motion, it will transmit an alarm, then enter sleep mode for 180 seconds; if motion is sensed when the sleep time has expired, the EN1266 will transmit another alarm. Fixed sleep time is recommended for normal operating environments. When set to variable, if the EN1266 senses motion, it will transmit an alarm, then enter sleep mode for 180 seconds; if motion is sensed before the sleep time has expired, the EN1266 will restart the 180 second interval. Variable sleep time is recommended for high-traffic operating environments, and is the default setting as shipped from the factory. To select sleep time:

  1. Press the tamper button four times within three seconds.

  2. Wait for the green LED to blink four times, then:

    • Press the tamper button one time within three seconds to select variable sleep time.
      Press the tamper button two times within three seconds to select fixed sleep time.
  3. Confirm your selection.

    • The green LED will blink once to indicate variable sleep time has been selected; twice to confirm fixed sleep time has been selected.

Register the EN1266

The EN1266 must be registered. Refer to receiver, network coordinator or control panel installation instructions to register the EN1266.

When prompted to reset the transmitter, remove and replace the batteries.

Caution: The EN1266 should be tested after registration to ensure operation. To test the EN1266, activate each of the conditions and ensure an appropriate response.

Mount the EN1266

Use the included four mounting screws to mount the EN1266 mounting base to the ceiling.

Note: The screw in the middle of the mounting base activates the tamper function if the EN1266 is removed from the ceiling.


Figure 4
Mount the EN1266

The EN1266 can be mounted to a maximum height of approximately 12 feet (3.6 meters). As mounting height increases, distance between detection zones also increases toward the perimeter, and the effects of factors such as floor surface temperature and intruder direction and speed are intensified. This can contribute to reducing speed of detection. Every installation should include a walk test of detection zones, including intrusion paths crossing the edges of the zones.

Installation Height Detection Diameter
8 feet (2.4 meters) 31 feet (9.5 meters)
10 feet (3.0 meters) 40 feet (12 meters)
12 feet (3.6 meters) 45.9 feet (14 meters)

EN1266 detection area
Figure 5
EN1266 detection area

When the housing base has been attached to the ceiling, attach the housing cover.

Test the EN1266

Walk Test

When in walk test mode the test LED will light red every time the EN1266 senses motion. The unit will not transmit alarm signals during this test period. Once initiated, the walk test will last for ten minutes and then the EN1266 will automatically return to normal operation. To initiate a walk test:

Press the tamper button three times within three seconds.

Note: The test LED only lights red during the walk test.

Operation

The EN1266 contains a tamper switch on the board to alert the user if the housing cover is removed. The EN1266 also contains tamper contacts in the mounting bracket to alert the user if the unit is removed from the wall.

Specifications

Dimensions: 4.33” x 1.77” (110mm x 45mm).
Weight: 4.37 oz. (123g).
Detection method: Quad-element PIR.
Operating temperature: 32°F to 120°F (0°C to 49°C).
Humidity: Up to 93% non-condensing.
Battery: Two Energizer Ultimate Lithium 1.5V AA.

Note: Battery is supervised.

Typical battery life: Two years in location with low to moderate activity.
Visible light protection: Stable against halogen light 8 feet (2.4m) or reflected light.
Temperature compensation: Yes.
Pulse count: Selectable single pulse or multiple pulse.

Television and Radio Interference

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Part 15 and Innovation, Science and Economic Development Canada

(ISED) Compliance

This device complies with part 15 of the FCC Rules, and ISED licenseexempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference that may cause undesired operation of the device.

Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Radiation Exposure Limits

FCC

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20 cm during normal operation and must not be co-located or operating in conjunction with any other antenna or transmitter.

ISED

This equipment complies with ISED RSS-102 radiation exposure limits set forth for an uncontrolled environment. This transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co- located or operating in conjunction with any other antenna or transmitter.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals