BRISTAN QD SHXSMFF C Quadrato Exposed Bar Shower with Riser Kit
Specifications
Tools You’ll Need
Prior to Installation
All products manufactured and supplied by Bristan are safe to use provided
that they are installed, operated and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999 and current
by-laws. For full Installation Requirements & Notes (IRN) please visit
wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of
future maintenance.
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder etc. This product must not be modified in
any way as this will invalidate the guarantee. Full access must be made
available for future maintenance/servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires,
cables or water supply pipes. This can be checked with the aid of an
electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
If in doubt, contact a registered plumber or your Local Water Authority or the
Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane, Hornchurch, Essex,
RM12 6NB, Tel: 01708 472791
Pack Contents
Installation
- Identify the required position of the valve and prepare the water supply pipes. Supply pipes should be 150mm apart.
- Using the backplate supplied with the wall mount, mark and drill holes.
- Secure the rubber and metal backplates into place.
- Secure the shrouds against the rubber fixing plates.
- Secure the shower to the wall mount, ensuring filters are in place.
Isolation
- Remove the concealing cap from the shroud.
- Rotate the shroud until the opening aligns with the isolation screw. Turn the screw to isolate the water. Reverse the process when turning the water back on.
Operation
Temperature Setting
- Turn the shower on and set the temperature to the maximum setting. Wait for the temperature to stabilise.
- Remove the temperature handle and temperature stop.
- Turn cartridge spindle clockwise to decrease the temperature. Turn cartridge spindle anti-clockwise to increase the temperature.
- Reverse the steps to replace the temperature stop and handle.
Maintenance – Cartridge Cleaning
-
Using the wall mount, isolate both shower inlets before carrying out any maintenance.
-
Remove the temperature and flow handles.
-
Undo the screw underneath the shower body to remove the cartridge.
-
Remove the cartridge retaining nut and cartridge.
-
Remove all O-rings and seals, check for damage and replace if necessary.
Soak all other components in a suitable solution until fully de-scaled. Rinse with clean water. Use WRAS approved grease on all seals before re- fitting. -
Reverse the steps to reinstall the valve, cartridge and handles.
-
Turn the water supply to the shower back on. Check all joints and connections for any leaks.
Servicing Intervals
To reduce the build up of limescale and to ensure this shower works to its
maximum performance we recommend this shower is serviced every 6-12 months
depending on the hardness of your water.
Spare Parts
To replace any spare parts for your shower why not scan the below QR Code and
search for your product.
Riser Installation
- Assemble both the top and bottom brackets.
- Attach the slider, hose retainer, top and bottom brackets to the riser rail.
- Ensuring its straight, use the assembled riser to mark the appropriate positions for the wall brackets.
- Remove the brackets from the riser. Mark and drill the holes before securing them to the wall.
- Re-attach the riser to the secured brackets.
- Connect the hose to the shower outlet and handset, feeding the hose through the hose retainer.
Place the handset in the slider.
Troubleshooting
Troubleshooting|
---|---
Symptom| Cause| Remedy
No flow or low flow rate| partially closed isolation valve.| Open isolation
valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too
low.| Increase water flow rate or pressure through system.
Head of water is below the minimum distance required.| 2 meters minimum
required.
Hot or cold water being drawn off elsewhere causing pressure changes or
instantaneous boiler temperature changes.| Do not use other water outlets when
using the taps.
Airlock or partial blockage in the supply pipework.| Flush through pipework to
ensure removal of debris and any airlocks.
Water dripping from shower| This is normal for a short time after using the
shower.| This is caused by residual water tension, the build up of water in
the shower.
If water continues to drip, possibly due to the cartridge| Remove cartridge
and clean, refer to ‘Maintenance’ section before starting any maintenance.
Shower does not turn on| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.
At Bristan, we want to make things as easy as possible for our customers.
That’s why we offer solid guarantees on all our products, effective from the
date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your
product. Alternatively visit
www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where
our expert team of advisors will be able to offer you any help and advice. For
full guarantee terms and conditions visit
www.bristan.com/guarantees.