- 4-STAGE AIR PURIFICATION
- CONTROLS
- WHERE TO USE
- INSTALLING THE FILTERS
- INSTALLING THE FILTERS
- SAFETY AND CAUTIONS
- INITIAL OPERATION
- AUTO AND SLEEP
- CHILD LOCK, AIR QUALITY LED
- FILTER CARE
- PARTICLE SENSOR CARE
- CLEANING CARE
- FREQUENTLY ASKED QUESTIONS
- UNIT SPECIFICATIONS
- PRODUCT WARRANTY
- MEMO
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WINIX AIR PURIFIER
User Manual
Model ZERO Pro (AZPU370-IWB)
Use & Care Guide
- Please read and follow all safety rules and instructions in this manual before operating.
- The product warranty is printed on the back of this guide, so please keep it in a safe place for future use.
4-STAGE AIR PURIFICATION
CONTROLS
WHERE TO USE
Allow 30 ~ 46 cm. of space between TVs, radios, and other electronic products
electromagnetic interference from certain electronics may cause product
malfunction.
Place indoors away from direct sun light direct exposure may cause product
malfunction or failure.
Only place on hard, flat surfaces flimsy or slanted surfaces may result in
abnormal noise and vibrations.
**WARNING
** Follow these instructions to reduce the risk of serious injury or death and
to reduce risk of damaging the unit.
Do not use around mist or fumes from industrial oil or around large
quantities of metallic dust.
Do not install in any sort of motor or transport vehicle (trucks, boats,
ships, etc.).
Do not place near any flammable materials (aerosols, fuel, gases etc.).
Do not place below any electrical outlet.
Do not place around heating elements.
Do not place in an area with excessive amounts of noxious gases.
Do not have unit facing into wind or draft.
Do not place in excessively humid areas where unit may become wet.
※ This unit is not intended to be used to preserve documents or in art conservation.
INSTALLING THE FILTERS
This product comes with all of the required filters. The protective plastic
wrap must be removed from the filters before use.
※ Operating the unit without removing the plastic wrap may result in product
failure.
※ Unplug and make sure the unit is turned off before installing filters.
※ The unit will automatically power off when front panel is opened.
-
Remove the front panel by grasping its upper edge and gently pulling towards yourself.
• To remove the front panel, the latch at the lower edge of the panel must be released from its position.
-
Remove the filters from the unit, they are protected inside a plastic wrap.
-
Remove filters from protective plastic wrap.
• Operating the unit without removing filters from plastic may cause abnormal noise, deformation, or fire as a result of overheating.
Refer to pages 15 – 18 for detailed information on filter care and how to replace them.
INSTALLING THE FILTERS
4. Install the filters until they fit securely in place.
Filters must be installed in this order:
3 True HEPA filter (rear)
2 AOC™ Carbon Filter (middle)
1 Pre-filter (front)
• To install the pre-filter, insert bottom tabs into the slots on either side
of the lower part of the unit, then rotate upward to insert the upper tabs
into the slots at the top part of the unit until both sides audibly click into
place.
5. Replace the front panel by first inserting the latch at the bottom edge
into the base of the unit, then rotate the panel upward toward the top of the
unit until it magnetically snaps closed.6. When to service and replace filters:
Filter| Indicator Light| When to service|
When to replace
---|---|---|---
1. Pre-filter| none| Clean once every 14 days| Permanent
2. AOCTM Carbon Filter|
Check Filter
| Clean once every 3 months| Lasts up to 612 months
3. True HEPA filter| Can NOT be WASHED
※ Intervals between filter replacement may vary depending on environment.
※ For optimal use, Pre-filter can be cleaned every 14 days which can extend
the life of other filters.
SAFETY AND CAUTIONS
Before operating this equipment, carefully read and follow these safety
cautions and instructions to avoid damage and ensure safe use.
Ensure filters are inserted before running unit running unit without filters
can shorten the units life and cause electric shock or injury.
Be sure foreign objects are NOT inserted into the vents on the unit objects
can include pins, rods, and coins.
Do not touch any part of the interior of the unit with wet hands the high
voltage may cause electric shock.
Ensure unit intake and outlet vents do not become blocked blockage may lead to
increased internal temperatures causing product failure and deformation.
Do not use the unit as a step stool or place heavy objects on it personal
injury may occur or product failure and deformation.
**WARNING
** Follow these instructions to reduce the risk of serious injury or death and
to reduce risk of damaging the unit.
Do not pull on the power cord when unplugging the unit.
If the unit becomes submerged in water, unplug it and contact customer
service.
Do not plug additional appliances into the same outlet or power supply.
Unplug unit when not in operation for extended periods of time.
Do not tie or knot power cord when unit is in operation.
Do not unplug or move the unit while in operation.
**** Do not touch the plug with wet hands.
Cord can become damaged by forcefully bending, pulling, twisting, bundling,
pinching or placing heavy objects on it.
※ If the supply cord is damaged, it must be replaced by a special cord or
assembly available from the manufacturer or its service agent.
※ This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards.
※ Children should be supervised to ensure that they do not play with the
appliance.
INITIAL OPERATION
-
Insert the unit plug into an electrical outlet.
• The Control Panel lights will turn on and off.
-
Press the ‘Power’ button.
During the first 4 minutes of power up, the Air Quality light will flash as the Smart Sensors measure the air quality in the environment, after which normal operation will begin. -
By default, when the unit first powers on, the mode will be set to Auto with PlasmaWave® enabled.
• When in Auto Mode the fan speed will be automatically adjusted according to the environments air quality.
• PlasmaWave ® works to remove harmful airborne contaminants.
-
• In Auto mode, as the indoor air quality improves, the fan speed will automatically be reduced to Low.
• When the unit is running, you may hear a chirping or buzzing sound. The sound is from large particles passing through PlasmaWave ® , it is normal and does not signify product failure. To disable PlasmaWave ® , see page 11.
AUTO AND SLEEP
Every time the Mode button is pressed, the Mode LED light will cycle through the settings. (Auto, Sleep, Low, Medium, High, Turbo)
-
Auto Mode
Enables Auto operation based on the unit’s air quality Smart Sensors.
① Press the Mode button to select Auto mode.
• The mode LED light will indicate when ‘Auto’ mode has been selected, and operation will begin.
• Each time the Mode button is pressed, the modes will be cycled. (Auto, Sleep, Low, Medium, High, Turbo).
• When in Auto Mode the fan speed is automatically adjusted according to the indoor air quality. As the indoor air quality improves, the fan speed will automatically be reduced. If the indoor air quality decreases the fan speed will automatically be increased.
• When unit is first started, Auto Mode is enabled and set to Low fan speed. -
Sleep Mode
① Press the Mode button to select Sleep mode.
• The mode LED light will indicate when ‘Sleep’ mode has been selected, and operation in that mode will begin.
• When Sleep mode is selected, the fan speed is automatically set to Low. Fan speed can be changed by pressing the Fan Speed (Mode) Button.
• When Sleep Mode is enabled, the Air Quality light is disabled.
MANUAL MODE, TIMER AND PLASMAWAVE®
Every time the Mode button is pressed, the Mode LED light will cycle through the settings. (Auto, Sleep, Low, Medium, High, Turbo) -
Manual Mode (setting fan speed)
Users can opt to manually set the fan speed to Low, Medium, High or Turbo.
① Press the Mode button to select the desired fan speed.
• The mode LED light will indicate the selected fan speed, and operation will begin.
• When Manual Mode is in use, Auto and Sleep modes are automatically disabled. -
Timer
The timer can be set for when you want the unit to run for a specified period of time.
① Select the desired period by pressing the Timer button.
• The Timer LED light will indicate the selected length of operation.
• Every time the Timer button is pressed the Timer LED light will cycle through the settings. (1hr, 4hr, 8hr, [NO TIMER]).
• The WINIX SMART app will display how much time is remaining on the timer.
PlasmaWave®
By default, PlasmaWave®is enabled whenever the unit is powered on.
① Press the PLASMAWAVE button when the power is on to enable or disable this
feature.
CHILD LOCK, AIR QUALITY LED
6. Child Lock
This feature prevents children from tampering with the control panel.
① Press and hold the Child Lock button for 3 seconds to enable or disable the
feature.
• When the Child Lock indicator is lit, the feature is enabled.
• When Child Lock is enabled, the control panel is locked and the settings
cannot be changed.
• To disable, press and hold the Child Lock button again for 3 seconds.
7. Air Quality LED Light
The Air Quality LED light may be turned on or off.
① To turn the Air Quality LED light on or off, press and hold the Timer button
for 3 seconds.
• When on, the LED light will indicate the current indoor air quality
according to four levels BLUE (good), GREEN (average), AMBER (fair), RED
(poor).
• When Auto Mode is enabled the Air Quality LED light may or may not be on,
depending on the amount of ambient light in the room.
• When Sleep Mode is activated, the Air Quality Indicator light is turned off.
FILTER CARE
- Changing Filters
When the Check Filter indicator LED is on, it is time to replace both the True HEPA filter and AOC™ Carbon filters. Filter| Indicator Light| When to service|
When to replace
---|---|---|---
1. Pre-filter| none| Clean once every 14 days| Permanent
2. AOCTM Carbon Filter|
Check Filter
| Clean once every 3 months| Lasts up to 612 months
3. True HEPA filter| Can NOT be WASHED
※ Intervals between filter replacement may vary depending on environment.
※ For optimal use, Pre-filter can be cleaned every 14 days which can extend
the life of other filters.
-
Removing Filters
Ensure the unit is turned off and unplugged before removing filters.
※ The unit will automatically power off when front panel is opened.
① Remove the front panel by grasping its upper edge and gently pulling towards yourself.
• To remove the front panel, the latch at the lower edge of the panel must be released from its position.
② Press the tabs on the top edge to remove the 1 Pre-filter. ③ First remove the 2 AOC™ Carbon Filter and then the 3 True HEPA filter by pulling on the numbered tags at the top of each filter. **WARNING
• For optimal performance, only genuine Winix filters should be used with this unit.
** -
Filter Assembly and Replacement
Filters should be re-installed in the reverse order of their removal.
① Insert the replacement
3 True HEPA filter (rear)
2 AOC™ Carbon Filter (middle)
• Remove the protective plastic wrap from new filters. Operating the unit without removing the protective plastic wrap may cause abnormal noise, deformation, or fire as a result of overheating.
② Insert the 1 Pre-filter (front)
• To install the pre-filter, insert bottom tabs into the slots on either side of the lower part of the unit, then rotate upward to insert the upper tabs into the slots at the top art of the unit until both sides audibly click into place.
③ Replace the front panel by first inserting the latch at the bottom edge into the base of the unit, then rotate the panel upward toward the top of the unit until it magnetically snaps closed. ④ After replacing the filters, turn the power back on and then use a thin object, such as a paper clip, to press the RESET switch for 5 seconds.
-
Cleaning the Pre-filter
Intervals between filter cleanings may vary depending on the air quality.
① Use a vacuum cleaner or soft brush to clean the Pre-filter. If it is excessively dirty, wash with room temperature water.
• Use only water, do not use volatile substances such as alcohol or acetone.
※ If the pre-filter becomes damaged or in any way needs replacement: Please contact your local dealer
NOTICE
• Do not use benzene, alcohol, or other volatile fluids, which may cause damage or discoloration.
• The Pre-filter is reusable after cleaning.
• Do not use hot water over 104°F or volatile fluids such as paint thinner.
• After washing the pre-filter, allow it to dry completely in a wellventilated area. Otherwise, it may develop a bad odor.
PARTICLE SENSOR CARE
Particle Sensors Care
For optimal performance of the Particle Sensor, which detects airborne dust
and ultrafine particles, clean it every two months. Clean it more frequently
when the unit is running in a place with high dust levels.
-
Open the Particle Sensor cover.
-
Use a damp cotton swab to wipe the lens and intake area of the Particle Sensor.
• To clean the sensor area, use only water. Do not use volatile substances such as alcohol or acetone.
-
Wipe away any remaining moisture with a dry cotton swab.
-
Close the Particle Sensor cover.
• The Particle Sensor cover may be cleaned using a vacuum cleaner.
CLEANING CARE
Cleaning the exterior and interior
Cleaning the exterior Wipe with a soft damp cloth using room temperature
water. Afterwards, wipe it down with a clean dry cloth. • For optimal
performance, clean the front panel 1-2 times a month.
Cleaning the interior
Open the front panel and clean the interior with a vacuum cleaner.
• For optimal performance, clean the interior 1-2 times a month.
NOTICE
- When cleaning the unit, always unplug the power cord first and then wait until the unit has cooled off.
- Never disassemble, repair or modify this unit yourself.
- Do not use flammable sprays or liquid detergents.
- Do not allow children to clean or maintain the unit
- Before cleaning or maintaining, ensure unit is off and unplugged.
FREQUENTLY ASKED QUESTIONS
Problem | Check / Actions to take |
---|
It does not turn on at all.
| • Is there a power outage?
– Check to see if other lights and electrical equipment are working and try
again.
It doesn’t work in Auto mode.
| • Has Auto mode been selected?
– Press the Mode button until Auto mode is selected.
• Is the sensor blocked or clogged?
– Clear the sensor using a vacuum cleaner. view page 19.
It vibrates and makes a lot of
noise.
| • Is it running on a slanted surface?
– Move the unit to a hard, flat area of the floor.
The power plug and outlet feel hot.
| • Is the plug securely plugged in?
– Make sure the plug is properly plugged into the outlet.
There is a strange smell.
| • Is it being used in a place with a lot of smoke, dust, or odors?
– Clean the air intakes on the front sides of the unit and clean the pre-
filter.
– Contact customer service to confirm the exact cause.
– Replace the AOC™ Carbon filter and True HEPA filter.
The product is not purifying the air enough.
| • Is the Check Filter indicator light on?
– Replace the filters as required.
UNIT SPECIFICATIONS
Model Name | ZERO Pro (AZPU370-IWB) |
---|---|
Power Voltage | AC220 – 240V, 50 / 60Hz |
Power Rate | 90 W |
Max Room Capacity | 120 m2 |
Dimensions | 415 mm(W) x 245 mm(D) x 600 mm(H) |
Weight | 8.5 kg |
Replacement Filter | Filter T / item : 1712-0093-01 |
Pre-Filter | Part : 4521-0010-01 |
※ The exterior, design, and product specifications may be changed to improve product performance without prior notice.
PRODUCT WARRANTY
The terms of the warranty are as follows.
- This product is manufactured under stringent quality control and inspections.
- Warranty void if product failure is a result of negligence or misuse by the consumer, shipping and service fees may be incurred even during the warranty period.
- The warranty must be presented upon bringing the product for service.
- Store the warranty in a safe place, as it cannot be reissued.
- This warranty is valid only in the Europe.
Product Name | Air Purifier |
---|---|
Model Name | ZERO Pro |
Purchase Date | |
Warranty period | Two (2) Years |
Customer | |
Address | |
Name | |
Tel. |
※ After purchase, be sure to complete all of the above information.
MEMO
Contact your local dealer for product related inquiries and customer service
www.winixeurope.eu
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>